Temporary Mechanical Circulatory Support with Axillary IABP or Impella 5.5 Versus Durable LVAD as Bridge to Heart Transplantation: A Strategy-Level Analysis in the Contemporary Allocation Era.
4 affiliations
- 1School of Health, Universidad Espíritu Santo-Ecuador, Samborondón 092301, Guayas, Ecuador.
- 2Department of Medicine, John H. Stroger Jr. Hospital of Cook County, Chicago, IL 60612, USA.
- 3Division of Heart Failure and Transplantation, Mayo Clinic, Jacksonville, FL 32224, USA.
- 4St. Elizabeth Medical Center, Boston, MA 02135, USA.
Abstract
Introduction: The 2018 revision of the United Network for Organ Sharing (UNOS) heart allocation system has shifted clinical practice toward increased use of temporary mechanical circulatory support (tMCS) as a bridge to transplantation (BTT). However, comparative outcomes between temporary and durable MCS strategies remain incompletely defined, particularly from a strategy-level perspective. We aim to compare clinical and peri-transplant outcomes between temporary and durable mechanical circulatory support strategies in patients undergoing heart transplantation. Methods: We conducted a single-center retrospective cohort study of consecutive adult patients who underwent orthotopic heart transplantation between October 2018 and October 2020. Patients were categorized according to MCS strategy as temporary (Impella 5.5 or axillary intra-aortic balloon pump) or durable left ventricular assist device (LVAD). Primary outcomes included device-to-transplant time, cardiopulmonary bypass time, and post-transplant ICU length of stay (LOS). Kaplan-Meier analysis and multivariable linear regression were used to evaluate outcomes and predictors. Results: A total of 26 patients were included, of whom 17 (65.4%) received tMCS and 9 (34.6%) durable LVAD support. Temporary MCS was associated with significantly shorter waitlist time (median 27.5-34 vs. 606 days, p = 0.002) and device-to-transplant time (7-13 vs. 572 days, p = 0.001). Kaplan-Meier analysis demonstrated significantly shorter time to transplantation with tMCS (log-rank χ² = 18.98, p < 0.001). In multivariable analysis, tMCS remained independently associated with shorter device-to-transplant time (B = -495.23; 95% CI -714.38 to -276.08; p = 0.001) and shorter cardiopulmonary bypass time (B = -88.85; 95% CI -126.32 to -51.38; p = 0.001). No statistically significant differences in post-transplant ICU LOS or other early post-transplant outcomes were detected between groups. Conclusions: In this single-center cohort, temporary MCS was associated with significantly shorter time to transplantation and shorter cardiopulmonary bypass times compared with durable LVAD support, while no statistically significant differences in early post-transplant outcomes were detected between groups.
Related
- Sex differences in temporary mechanical circulatory support, vascular complications, and mortality in acute myocardial infarction with cardiogenic shock: a contemporary national analysis, 2016 to 2023.
- Temporary Mechanical Circulatory Support in Acute Myocardial Infarction-Related Cardiogenic Shock: Lessons from Contemporary Randomized Trials
- Limiting collateral damage: Nosocomial infections in patients with temporary mechanical circulatory support.
- Temporary Mechanical Circulatory Support
- Canadian Patterns of Temporary Mechanical Circulatory Support: A Report by the C3 Cardiogenic Shock Working Group
BibTeX
@article{mautong2026temporary,
title = {{Temporary Mechanical Circulatory Support with Axillary IABP or Impella 5.5 Versus Durable LVAD as Bridge to Heart Transplantation: A Strategy-Level Analysis in the Contemporary Allocation Era.}},
author = {Hans Mautong and Aarti Desai and Laxmi Raj Bangari and Andrea Muniz and Shriya Sharma and Jose Ruiz and Daniel S Yip and Melissa A Lyle and Jose Nativi-Nicolau and Juan Leoni and Parag Patel and Rohan Goswami},
journal = {Journal of cardiovascular development and disease},
year = {2026},
month = nov,
doi = {10.3390/jcdd13110588},
url = {https://europepmc.org/article/MED/43083095},
note = {CC BY},
}
RIS
TY - JOUR
TI - Temporary Mechanical Circulatory Support with Axillary IABP or Impella 5.5 Versus Durable LVAD as Bridge to Heart Transplantation: A Strategy-Level Analysis in the Contemporary Allocation Era.
AU - Hans Mautong
AU - Aarti Desai
AU - Laxmi Raj Bangari
AU - Andrea Muniz
AU - Shriya Sharma
AU - Jose Ruiz
AU - Daniel S Yip
AU - Melissa A Lyle
AU - Jose Nativi-Nicolau
AU - Juan Leoni
AU - Parag Patel
AU - Rohan Goswami
PY - 2026
DA - 2026/11/12
JO - Journal of cardiovascular development and disease
DO - 10.3390/jcdd13110588
UR - https://europepmc.org/article/MED/43083095
AB - Introduction: The 2018 revision of the United Network for Organ Sharing (UNOS) heart allocation system has shifted clinical practice toward increased use of temporary mechanical circulatory support (tMCS) as a bridge to transplantation (BTT). However, comparative outcomes between temporary and durable MCS strategies remain incompletely defined, particularly from a strategy-level perspective. We aim to compare clinical and peri-transplant outcomes between temporary and durable mechanical circulatory support strategies in patients undergoing heart transplantation. Methods: We conducted a single-center retrospective cohort study of consecutive adult patients who underwent orthotopic heart transplantation between October 2018 and October 2020. Patients were categorized according to MCS strategy as temporary (Impella 5.5 or axillary intra-aortic balloon pump) or durable left ventricular assist device (LVAD). Primary outcomes included device-to-transplant time, cardiopulmonary bypass time, and post-transplant ICU length of stay (LOS). Kaplan-Meier analysis and multivariable linear regression were used to evaluate outcomes and predictors. Results: A total of 26 patients were included, of whom 17 (65.4%) received tMCS and 9 (34.6%) durable LVAD support. Temporary MCS was associated with significantly shorter waitlist time (median 27.5-34 vs. 606 days, p = 0.002) and device-to-transplant time (7-13 vs. 572 days, p = 0.001). Kaplan-Meier analysis demonstrated significantly shorter time to transplantation with tMCS (log-rank χ² = 18.98, p < 0.001). In multivariable analysis, tMCS remained independently associated with shorter device-to-transplant time (B = -495.23; 95% CI -714.38 to -276.08; p = 0.001) and shorter cardiopulmonary bypass time (B = -88.85; 95% CI -126.32 to -51.38; p = 0.001). No statistically significant differences in post-transplant ICU LOS or other early post-transplant outcomes were detected between groups. Conclusions: In this single-center cohort, temporary MCS was associated with significantly shorter time to transplantation and shorter cardiopulmonary bypass times compared with durable LVAD support, while no statistically significant differences in early post-transplant outcomes were detected between groups.
SN - 2308-3425
ER -