Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 8 min ago
PreprintCC BY 4.0arXiv

Characterization of IBEX LmAPD detectors at CEA for future low-noise NIR astronomy instruments

Abstract

Future near-infrared (NIR) astronomy missions dedicated to photon-starved science cases, in particular an all-sky astrometric survey extending the legacy of Gaia into the NIR, as identified within the ESA Voyage~2050 programme, require large-format detectors combining sub-electron effective read noise with very low dark current. Linear-mode avalanche photodiodes (LmAPDs) based on HgCdTe meet this need by multiplying the photo-generated charge by an avalanche gain before the readout stage, thereby reducing the relative contribution of the read noise. We report the first electro-optical characterization of an IBEX detector, a 2048×2048, \SI{15}{\micro\meter}-pitch HgCdTe LmAPD array developed by Leonardo with the European Space Agency and operated at \SI{80}{\kelvin} on a dedicated bench at CEA-IRFU. We first discuss the central difficulty of characterizing an APD array, the degeneracy between avalanche gain, quantum efficiency (QE), and conversion gain in the measured response, and we then separate the measurements into two categories. Among the quantities that are directly measurable without assumptions, we report a signal-to-noise ratio for a CDS measurement that exceeds that of a Euclid-type H2RG above \SI{8}{\volt} pixel bias under identical low-flux conditions, a photo-response non-uniformity stable at the ∼10\% level, and a quantum efficiency-to-excess-noise ratio (QEFR) of \num{0.40} at \SI{10.5}{\volt}. Among the quantities derived under an explicit set of assumptions, we obtain a conversion gain corresponding to a sense-node capacitance of \SI{27}{\femto\farad}, a quantum efficiency of 46±12% at \SI{2.5}{\volt}, and an excess noise factor F=1.15±0.14 at \SI{10.5}{\volt}. These results establish IBEX as a promising European large-format detector for future ultra-low-flux NIR instruments.

Versions

Related

  1. Prospects for Simultaneously Detecting Long and Short Duration Gravitational Waves from Pulsar Glitches with Current and Future Detectors
    M. Ball, D. Keitel
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsGravitation & general relativityarXiv
  2. Synergy between CSST and future gravitational-wave detectors: Probing primordial black holes by cross-correlating dark sirens with galaxies
    Ya-Nan Du, Ji-Yu Song, Jing-Fei Zhang +1
    arXivPreprintCC BY 4.0Full textCosmologyGalaxiesarXiv
  3. State of the Art in Direct Dark Matter Detectors: Technologies, Performance, and Future Directions
    Muad Ghaith, Khaled Obaideen
    arXivPreprintarXiv licenceFull textGalaxiesApplied physics & instrumentationarXiv
  4. Development, Configuration and Performance Characterization of a Scalable BETA ASIC-Based Readout System for Multi-Channel SiPM Detectors
    Giulio Lucchetta, Keerthana Rajan Lathika, Benjamin Nobre Hauptmann +17
    arXivPreprintarXiv licenceFull textInstrumentation & methodsApplied physics & instrumentationarXiv
  5. Laboratory Characterization of a Ge-CCD Prototype for Future Near-Infrared Astronomical Instrumentation
    Emi Tamura, Juan Cruz Estrada Vigil, Prashansa Mukim +6
    arXivPreprintarXiv licenceFull textInstrumentation & methodsHigh-energy & particle physicsarXiv
BibTeX
@misc{graet2026characterization,
  title = {{Characterization of IBEX LmAPD detectors at CEA for future low-noise NIR astronomy instruments}},
  author = {Jean Le Graët and Vincent Affatato and Marion Baumann and Olivier Boulade and Cyrille Delisle and Eloy Hernandez and Christian Ketchazo and Frederic Lemmel and Vincent Moreau and Salima Mouzali and Thibault Pichon and François Visticot},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.17371},
  eprint = {2609.17371},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.17371},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Characterization of IBEX LmAPD detectors at CEA for future low-noise NIR astronomy instruments
AU  - Jean Le Graët
AU  - Vincent Affatato
AU  - Marion Baumann
AU  - Olivier Boulade
AU  - Cyrille Delisle
AU  - Eloy Hernandez
AU  - Christian Ketchazo
AU  - Frederic Lemmel
AU  - Vincent Moreau
AU  - Salima Mouzali
AU  - Thibault Pichon
AU  - François Visticot
PY  - 2026
DA  - 2026/09/15
PB  - arXiv
DO  - 10.48550/arxiv.2609.17371
UR  - https://arxiv.org/abs/2609.17371
AB  - Future near-infrared (NIR) astronomy missions dedicated to photon-starved science cases, in particular an all-sky astrometric survey extending the legacy of Gaia into the NIR, as identified within the ESA Voyage~2050 programme, require large-format detectors combining sub-electron effective read noise with very low dark current. Linear-mode avalanche photodiodes (LmAPDs) based on HgCdTe meet this need by multiplying the photo-generated charge by an avalanche gain before the readout stage, thereby reducing the relative contribution of the read noise. We report the first electro-optical characterization of an IBEX detector, a 2048×2048, \SI{15}{\micro\meter}-pitch HgCdTe LmAPD array developed by Leonardo with the European Space Agency and operated at \SI{80}{\kelvin} on a dedicated bench at CEA-IRFU. We first discuss the central difficulty of characterizing an APD array, the degeneracy between avalanche gain, quantum efficiency (QE), and conversion gain in the measured response, and we then separate the measurements into two categories. Among the quantities that are directly measurable without assumptions, we report a signal-to-noise ratio for a CDS measurement that exceeds that of a Euclid-type H2RG above \SI{8}{\volt} pixel bias under identical low-flux conditions, a photo-response non-uniformity stable at the ∼10\% level, and a quantum efficiency-to-excess-noise ratio (QEFR) of \num{0.40} at \SI{10.5}{\volt}. Among the quantities derived under an explicit set of assumptions, we obtain a conversion gain corresponding to a sense-node capacitance of \SI{27}{\femto\farad}, a quantum efficiency of 46±12% at \SI{2.5}{\volt}, and an excess noise factor F=1.15±0.14 at \SI{10.5}{\volt}. These results establish IBEX as a promising European large-format detector for future ultra-low-flux NIR instruments.
ER  -