Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
- 1Division of Cardiology, Department of Medicine University of Baltimore Baltimore Maryland USA
- 2Division of Vascular Surgery, Department of Surgery University of Maryland Baltimore Maryland USA
Abstract
Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are presenting a complete percutaneous retrieval of M‐TEER device from the right subclavian artery, which indicates the importance of procedural planning and appropriate equipment selection.
Related
- Atypical presentation of subclavian steal syndrome mimicking transient ischemic attack: successful endovascular management with angiographic correlation—a case report
- Successful Bailout Retrieval of an Active‐Fixation Atrial Leadless Pacemaker Following Suspected Tissue Entrapment During Repositioning
- Successful balloon-assisted percutaneous thrombin injection for common femoral artery pseudoaneurysm after venoarterial extracorporeal membrane oxygenation decannulation.
- Modified interventional retrieval of a balloon with transverse rupture during percutaneous transluminal angioplasty of a vascular access: a case report
- Endovascular retrieval of bone cement entrapped in an inferior vena cava filter after percutaneous vertebroplasty: a case report
BibTeX
@article{aalaeiandabili2026successful,
title = {{Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery}},
author = {Seyed Hossein Aalaei‐Andabili and Diljon S. Chahal and Shahab Tour Savadkohi},
journal = {Catheterization and Cardiovascular Interventions},
year = {2026},
month = sep,
doi = {10.1002/ccd.70860},
url = {https://doi.org/10.1002/ccd.70860},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Successful Percutaneous Retrieval of an Embolized MitraClip From the Right Subclavian Artery
AU - Seyed Hossein Aalaei‐Andabili
AU - Diljon S. Chahal
AU - Shahab Tour Savadkohi
PY - 2026
DA - 2026/09/09
JO - Catheterization and Cardiovascular Interventions
DO - 10.1002/ccd.70860
UR - https://doi.org/10.1002/ccd.70860
AB - Single leaflet device attachment (SLDA) after mitral transcatheter valve edge‐to‐edge repair (M‐TEER) has been reported in up to 5% of patients. However, complete embolization of the M‐TEER device is exceedingly rare. Device retrievals in all previously reported cases were completed by vascular surgery cut down at the end. In this case, we are presenting a complete percutaneous retrieval of M‐TEER device from the right subclavian artery, which indicates the importance of procedural planning and appropriate equipment selection.
SN - 1522-1946
SN - 1522-726X
ER -