Comparison of DBS measurements of turbulence spectra by vertical-displacement and poloidal-angle scans using the Scotty synthetic diagnostic
Abstract
Doppler backscattering (DBS) measures electron density fluctuations. The measured wavenumber is typically varied by changing the probe beam poloidal launch angle. As most DBS systems are unable to steer during a shot, the shot is repeated and the poloidal angle is changed intershot. An alternative method is to keep the DBS launch angle fixed and move the plasma up and down instead, enabling a range of wavenumbers to be measured within a single shot. We call this the bouncing ball method. We use the Scotty synthetic diagnostic (Hall-Chen, 2022) to evaluate the similarities and differences between these two approaches. Both approaches are capable of measuring a similar range of fluctuation wavenumbers as well as radial locations. However, the vertical-displacement scan has a larger range of measured poloidal locations than the poloidal-angle scan. Using the same synthetic turbulence spectrum as input, we show that the two approaches are expected to have different backscattered powers due to different instrumentation functions. When mismatch attenuation is accounted for via a synthetic diagnostic, the vertical-displacement scan can provide comparable radial and wavenumber coverage while reducing reliance on shot-to-shot repeatability. These results establish vertical-displacement scan as a practical route to single-shot DBS wavenumber spectra.
Related
- Phase-field digital image correlation for integrated displacement and damage measurements
- Stochastic Operator Inference for reduced-order modeling of capillary wave turbulence using experimental measurements
- Synthetic 2D magnetic turbulence with controlled island structuring
- Evaluating the Reliability of Cross-Instrument Comparison: (p)XRF Measurements of Two Rare 'Kangxi-Reign' Enameled Glasses
- Covariance scaling and a dual-mode torque diagnostic in measurements of the gravitational constant
BibTeX
@misc{tan2026comparison,
title = {{Comparison of DBS measurements of turbulence spectra by vertical-displacement and poloidal-angle scans using the Scotty synthetic diagnostic}},
author = {Y. T. Tan and V. Hall-Chen and T. Rhodes},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2607.09219},
eprint = {2607.09219},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2607.09219},
}
RIS
TY - UNPB
TI - Comparison of DBS measurements of turbulence spectra by vertical-displacement and poloidal-angle scans using the Scotty synthetic diagnostic
AU - Y. T. Tan
AU - V. Hall-Chen
AU - T. Rhodes
PY - 2026
DA - 2026/09/04
PB - arXiv
DO - 10.48550/arxiv.2607.09219
UR - https://arxiv.org/abs/2607.09219
AB - Doppler backscattering (DBS) measures electron density fluctuations. The measured wavenumber is typically varied by changing the probe beam poloidal launch angle. As most DBS systems are unable to steer during a shot, the shot is repeated and the poloidal angle is changed intershot. An alternative method is to keep the DBS launch angle fixed and move the plasma up and down instead, enabling a range of wavenumbers to be measured within a single shot. We call this the bouncing ball method. We use the Scotty synthetic diagnostic (Hall-Chen, 2022) to evaluate the similarities and differences between these two approaches. Both approaches are capable of measuring a similar range of fluctuation wavenumbers as well as radial locations. However, the vertical-displacement scan has a larger range of measured poloidal locations than the poloidal-angle scan. Using the same synthetic turbulence spectrum as input, we show that the two approaches are expected to have different backscattered powers due to different instrumentation functions. When mismatch attenuation is accounted for via a synthetic diagnostic, the vertical-displacement scan can provide comparable radial and wavenumber coverage while reducing reliance on shot-to-shot repeatability. These results establish vertical-displacement scan as a practical route to single-shot DBS wavenumber spectra.
ER -