Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYEuropean heart journal. Digital health

Predicting cardiopulmonary exercise testing performance in patients undergoing transthoracic echocardiography—an artificial intelligence–based, multimodal model

10 more authors
8 affiliations
  1. 1Department of Cardiology, NewYork Presbyterian-Brooklyn Methodist Hospital, 506 Sixth St, Brooklyn, NY 11215, USA.
  2. 2Department of Population Health Sciences, Weill Cornell Medicine, Cornell University, New York, NY, USA.
  3. 3Division of Cardiology, Department of Medicine, Weill Cornell Medicine, New York, NY, USA.
  4. 4Information Technology Data Science, New York Presbyterian Hospital, New York, NY, USA.
  5. 5Department of Computer Science, Cornell University, Ithaca, NY, USA.
  6. 6Seymour, Paul, and Gloria Milstein Division of Cardiology, Department of Medicine, Columbia University Irving Medical Center/New York Presbyterian Hospital, New York, NY, USA.
  7. 7Computer Science Department, Cornell Tech, New York, NY, USA.
  8. 8Heart Failure Research Institute, New York Presbyterian Hospital, New York, NY, USA.

Abstract

Aims

Cardiopulmonary exercise test (CPET) performance strongly correlates with survival in several disease states including heart failure, but has limited accessibility. Meanwhile, transthoracic echocardiography (TTE) is a far more widely available tool. We sought to develop an artificial intelligence (AI) algorithm using TTE and data from electronic medical records to predict CPET peak oxygen consumption (peak VO₂) ≤ 14 mL/kg/min.Methods and results

An AI model was trained to predict peak VO₂ ≤ 14 mL/kg/min from TTE images, structured TTE reports, demographics, medications, laboratory tests, and vitals. The training set included patients with a TTE within 6 months of a CPET. Performance was retrospectively tested in a held-out group from the development cohort and an external regional validation cohort. A total of 1127 CPET studies paired with concomitant TTE were identified. The best performance was achieved by using all components (TTE images, all structured clinical data). The model performed well at predicting a peak VO₂ ≤ 14 mL/kg/min, with an area under the receiver operating characteristic curve of 0.84 (development cohort) and 0.80 (external validation cohort). It performed consistently well using higher (≤18 mL/kg/min) and lower (≤12 mL/kg/min) cut-offs.Conclusion

This multimodal AI model effectively categorized patients into low- and high-risk predicted peak VO₂, demonstrating the potential to identify previously unrecognized high-risk patients when CPET is not available.

Related

  1. Predicting fluid responsiveness in mechanically ventilated children under general anaesthesia using dynamic parameters and transthoracic echocardiography
    E. Pereira de Souza Neto, S. Grousson, F. Duflo +6
    British Journal of AnaesthesiaPeer-reviewedLicence not stated142 citedSurgery & anaesthesiaHAL
  2. Artificial Intelligence for Automated Continuous Quantification of Left Ventricular Ejection Fraction From Standard Adult Transthoracic Echocardiography: A Systematic Review.
    Aniket Dembi, Hilary Patankar, Simran Dhadda +1
    CureusPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Feasibility and Safety of Transthoracic Echocardiography–Guided Transvenous Permanent Pacemaker Implantation Without Fluoroscopy
    JACC. AdvancesPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Transthoracic echocardiography vs. cardiac magnetic resonance imaging for the diagnosis of left ventricular thrombus: an updated systematic review and diagnostic accuracy meta-analysis
    European heart journal. Imaging methods and practicePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. A Single-Center Retrospective Analysis of the Diagnostic Efficacy of Transthoracic Echocardiography in the Classification of Patent Ductus Arteriosus
    Minxin Zhang, Chen Qian, Shuang Wang +3
    Reviews in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{alishetti2026predicting,
  title = {{Predicting cardiopulmonary exercise testing performance in patients undergoing transthoracic echocardiography—an artificial intelligence–based, multimodal model}},
  author = {Shudhanshu Alishetti and Weishen Pan and Ashley N Beecy and Zhenzhen Liu and Albert Gong and Zhe Huang and Kevin J Clerkin and Ilan Richter and Rochelle L Goldsmith and David T Majure and Chris Kelsey and David vanMaanan and Jeffrey Ruhl and Naomi Tesfuzigta and Erica Lancet and Deepa Kumaraiah and Gabriel Sayer and Deborah Estrin and Kilian Weinberger and Volodymyr Kuleshov and Fei Wang and Nir Uriel},
  journal = {European heart journal. Digital health},
  year = {2026},
  month = nov,
  doi = {10.1093/ehjdh/ztag172},
  url = {https://europepmc.org/article/PMC/PMC13795263},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Predicting cardiopulmonary exercise testing performance in patients undergoing transthoracic echocardiography—an artificial intelligence–based, multimodal model
AU  - Shudhanshu Alishetti
AU  - Weishen Pan
AU  - Ashley N Beecy
AU  - Zhenzhen Liu
AU  - Albert Gong
AU  - Zhe Huang
AU  - Kevin J Clerkin
AU  - Ilan Richter
AU  - Rochelle L Goldsmith
AU  - David T Majure
AU  - Chris Kelsey
AU  - David vanMaanan
AU  - Jeffrey Ruhl
AU  - Naomi Tesfuzigta
AU  - Erica Lancet
AU  - Deepa Kumaraiah
AU  - Gabriel Sayer
AU  - Deborah Estrin
AU  - Kilian Weinberger
AU  - Volodymyr Kuleshov
AU  - Fei Wang
AU  - Nir Uriel
PY  - 2026
DA  - 2026/11/18
JO  - European heart journal. Digital health
DO  - 10.1093/ehjdh/ztag172
UR  - https://europepmc.org/article/PMC/PMC13795263
AB  - Aims  Cardiopulmonary exercise test (CPET) performance strongly correlates with survival in several disease states including heart failure, but has limited accessibility. Meanwhile, transthoracic echocardiography (TTE) is a far more widely available tool. We sought to develop an artificial intelligence (AI) algorithm using TTE and data from electronic medical records to predict CPET peak oxygen consumption (peak VO₂) ≤ 14 mL/kg/min.Methods and results  An AI model was trained to predict peak VO₂ ≤ 14 mL/kg/min from TTE images, structured TTE reports, demographics, medications, laboratory tests, and vitals. The training set included patients with a TTE within 6 months of a CPET. Performance was retrospectively tested in a held-out group from the development cohort and an external regional validation cohort. A total of 1127 CPET studies paired with concomitant TTE were identified. The best performance was achieved by using all components (TTE images, all structured clinical data). The model performed well at predicting a peak VO₂ ≤ 14 mL/kg/min, with an area under the receiver operating characteristic curve of 0.84 (development cohort) and 0.80 (external validation cohort). It performed consistently well using higher (≤18 mL/kg/min) and lower (≤12 mL/kg/min) cut-offs.Conclusion  This multimodal AI model effectively categorized patients into low- and high-risk predicted peak VO₂, demonstrating the potential to identify previously unrecognized high-risk patients when CPET is not available.
SN  - 2634-3916
ER  -