This paper investigates the finite-time boundedness problem of hybrid wind–diesel power systems through an attack-resilient load frequency control framework in the presence of hybrid cyber attacks and multiple disturbances. The considered disturbances include matched disturbances and mismatched disturbances. To address these challenges, an output-reliant disturbance observer is developed to accurately estimate the matched disturbances, while a dissipative mechanism is employed to attenuate the effects of mismatched disturbances. By utilizing the disturbance estimates and the measured system output, a proportional–integral observer is constructed to estimate the system states. Subsequently, an attack-resilient load frequency controller is designed based on the estimated states and disturbances. Furthermore, multimodal false-data-injection and replay attacks are incorporated into the controller channel to realistically model hybrid cyber threats and enhance controller resilience. Based on Lyapunov stability theory and finite-time stability concepts, sufficient stability conditions are derived in terms of linear matrix inequalities to guarantee finite-time boundedness of the closed-loop system. These conditions also provide a systematic approach for computing the observer and controller gain matrices. Finally, simulation results are presented to demonstrate the effectiveness and robustness of the developed control scheme under hybrid cyber attacks and multiple disturbances.
Related
- Dynamic Trust-Driven Resilient Finite-/Fixed-Time Formation Control for Multi-UAV Systems with Input Saturation Against Sybil Attacks
- Resilient Extremum Seeking Control for Cyber-Physical Systems Under Denial-of-Service Attacks
- Practical Predefined-Time Safe Resilient Consensus of Heterogeneous Nonlinear Fractional-Order Multi-Agent Systems Under Hybrid Cyber Attacks
- MIMO and Multi-Group Comparison Problem in Process Control: A Multivariate Statistical Framework for Systems Represented with Frequency Response Functions
- Model Predictive Control: Systematic Design Tailored to Nonholonomic Systems
BibTeX
@article{thangavel2026design,
title = {{Design of Attack-Resilient Load Frequency Control for Hybrid Wind–Diesel Power Systems Under Hybrid Cyber Attacks}},
author = {Satheesh Thangavel and Oh-Min Kwon and Sakthivel Rathinasamy and Parthasarathy Velusamy},
journal = {Mathematics},
year = {2026},
month = nov,
doi = {10.3390/math14213980},
url = {https://www.mdpi.com/2227-7390/14/21/3980},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Design of Attack-Resilient Load Frequency Control for Hybrid Wind–Diesel Power Systems Under Hybrid Cyber Attacks
AU - Satheesh Thangavel
AU - Oh-Min Kwon
AU - Sakthivel Rathinasamy
AU - Parthasarathy Velusamy
PY - 2026
DA - 2026/11/01
JO - Mathematics
DO - 10.3390/math14213980
UR - https://www.mdpi.com/2227-7390/14/21/3980
AB - This paper investigates the finite-time boundedness problem of hybrid wind–diesel power systems through an attack-resilient load frequency control framework in the presence of hybrid cyber attacks and multiple disturbances. The considered disturbances include matched disturbances and mismatched disturbances. To address these challenges, an output-reliant disturbance observer is developed to accurately estimate the matched disturbances, while a dissipative mechanism is employed to attenuate the effects of mismatched disturbances. By utilizing the disturbance estimates and the measured system output, a proportional–integral observer is constructed to estimate the system states. Subsequently, an attack-resilient load frequency controller is designed based on the estimated states and disturbances. Furthermore, multimodal false-data-injection and replay attacks are incorporated into the controller channel to realistically model hybrid cyber threats and enhance controller resilience. Based on Lyapunov stability theory and finite-time stability concepts, sufficient stability conditions are derived in terms of linear matrix inequalities to guarantee finite-time boundedness of the closed-loop system. These conditions also provide a systematic approach for computing the observer and controller gain matrices. Finally, simulation results are presented to demonstrate the effectiveness and robustness of the developed control scheme under hybrid cyber attacks and multiple disturbances.
SN - 2227-7390
ER -