Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BYCureus

Very Early-Onset Prosthetic Valve Endocarditis Following Transcatheter Aortic Valve Implantation Complicated by an Aorto-Left Atrial Fistula and Aortic Root Pseudoaneurysm

  1. 1Interventional Cardiology Unit, Hospital General Universitario de Ciudad Real, Ciudad Real, ESP
  2. 2Clinical Cardiology Unit, Hospital General Universitario de Ciudad Real, Ciudad Real, ESP

Abstract

Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis. Infective endocarditis (IE) is an uncommon but potentially devastating complication, typically presenting weeks to months after valve implantation. Very early-onset prosthetic valve endocarditis (PVE), occurring within 48 hours of implantation, poses a particular diagnostic challenge, as infectious complications must be distinguished from procedure-related structural injury and sterile postprocedural inflammatory changes. We report the case of an 81-year-old man who underwent transfemoral TAVI with a self-expanding Evolut FX valve for severe symptomatic aortic stenosis. The procedure was uneventful, with satisfactory immediate angiographic and echocardiographic findings. Within 48 hours, the patient developed fever and elevated inflammatory markers. Two independent blood culture sets were positive for methicillin-susceptible Staphylococcus aureus (MSSA). Fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) demonstrated increased metabolic uptake at the aortic root. Given the early postprocedural timing, this finding was interpreted cautiously, as sterile inflammatory changes could not be excluded. Subsequent transesophageal echocardiography (TEE) revealed a prosthetic valve vegetation, an aortic-root pseudoaneurysm, and an aorto-left atrial fistula with continuous shunt flow. The combination of microbiological and echocardiographic findings fulfilled the diagnostic criteria for definite prosthetic valve IE. Surgical intervention was considered prohibitive by the multidisciplinary Heart Team, and antimicrobial treatment was administered. Despite treatment, the patient's clinical condition rapidly deteriorated, resulting in death within one week of diagnosis. This case highlights the importance of integrating clinical and microbiological findings with multimodality imaging in diagnosing very early-onset PVE, while carefully considering potential procedure-related structural injury.

Related

  1. Prosthetic Aortic Valve Infective Endocarditis Complicated With Malignant Arrhythmias: Diagnostic and Management Challenges
    Imthiaz Manoly, Safia Fathima Anver Pasha, Mohannad M Al Asaad +1
    CureusPeer-reviewedCC BY 4.0Full textInfectious diseasePMC
  2. Actinotignum-associated prosthetic aortic valve endocarditis complicated by postoperative circulatory collapse and dialysis-requiring acute kidney injury: a case report.
    Norihiro Sakai, Aya Seki, Tomohiro Michino
    BMC infectious diseasesPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMCPMC
  3. Transcatheter closure of ascending aortic pseudoaneurysm via steerable sheath assisted atrial septal occluder device delivery
    Nivedita Pant, Muzammil H. Musani
    Journal of Cardiology CasesPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  4. Recurrent Prosthetic Valve Endocarditis With Aortic Root Abscess in Fontan Circulation
    Ahmed Wahba, Sameh M. Said
    JACC Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMC
  5. From Valve to Spine and Spleen: Multisystem Complications of Gemella haemolysans Prosthetic‐Valve Endocarditis
    Eric Baghdasaryan, Sari Lada, Rafi Orphali +2
    Case Reports in CardiologyPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMCEurope PMC
BibTeX
@article{dascoli2026very,
  title = {{Very Early-Onset Prosthetic Valve Endocarditis Following Transcatheter Aortic Valve Implantation Complicated by an Aorto-Left Atrial Fistula and Aortic Root Pseudoaneurysm}},
  author = {Giulio D'Ascoli and Jesús Piqueras-Flores and Carlos Sánchez Sánchez and Fernando Lozano Ruiz-Poveda},
  journal = {Cureus},
  year = {2026},
  month = oct,
  doi = {10.7759/cureus.118467},
  url = {https://europepmc.org/article/PMC/PMC13789482},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Very Early-Onset Prosthetic Valve Endocarditis Following Transcatheter Aortic Valve Implantation Complicated by an Aorto-Left Atrial Fistula and Aortic Root Pseudoaneurysm
AU  - Giulio D'Ascoli
AU  - Jesús Piqueras-Flores
AU  - Carlos Sánchez Sánchez
AU  - Fernando Lozano Ruiz-Poveda
PY  - 2026
DA  - 2026/10/23
JO  - Cureus
DO  - 10.7759/cureus.118467
UR  - https://europepmc.org/article/PMC/PMC13789482
AB  - Transcatheter aortic valve implantation (TAVI) is an established treatment for severe aortic stenosis. Infective endocarditis (IE) is an uncommon but potentially devastating complication, typically presenting weeks to months after valve implantation. Very early-onset prosthetic valve endocarditis (PVE), occurring within 48 hours of implantation, poses a particular diagnostic challenge, as infectious complications must be distinguished from procedure-related structural injury and sterile postprocedural inflammatory changes. We report the case of an 81-year-old man who underwent transfemoral TAVI with a self-expanding Evolut FX valve for severe symptomatic aortic stenosis. The procedure was uneventful, with satisfactory immediate angiographic and echocardiographic findings. Within 48 hours, the patient developed fever and elevated inflammatory markers. Two independent blood culture sets were positive for methicillin-susceptible Staphylococcus aureus (MSSA). Fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) demonstrated increased metabolic uptake at the aortic root. Given the early postprocedural timing, this finding was interpreted cautiously, as sterile inflammatory changes could not be excluded. Subsequent transesophageal echocardiography (TEE) revealed a prosthetic valve vegetation, an aortic-root pseudoaneurysm, and an aorto-left atrial fistula with continuous shunt flow. The combination of microbiological and echocardiographic findings fulfilled the diagnostic criteria for definite prosthetic valve IE. Surgical intervention was considered prohibitive by the multidisciplinary Heart Team, and antimicrobial treatment was administered. Despite treatment, the patient's clinical condition rapidly deteriorated, resulting in death within one week of diagnosis. This case highlights the importance of integrating clinical and microbiological findings with multimodality imaging in diagnosing very early-onset PVE, while carefully considering potential procedure-related structural injury.
SN  - 2168-8184
ER  -