Determination and Quantitation of Key Secoiridoids and Polyphenols in Olive Extracts Using UHPLC-PDA
- 1Applied Food Sciences, Inc., 2500 Crosspark Road, Coralville, IA 52241, USA
Abstract
Olive extracts are increasingly used as concentrated, formulation-ready sources of olive phenolics and secoiridoids, yet many published chromatographic methods only focus on one or two identified compounds, limiting broader compositional screening and producttoproduct differentiation. To address this gap, a UHPLC–PDA method was developed for the simultaneous identification and quantitation of six key olive bioactives (hydroxytyrosol, tyrosol, oleuropein, oleuroside, oleacein, and oleocanthal) in powdered olive extract matrices. Samples were extracted in 80% acetonitrile using sonication and centrifugation, then separated on a C18 column with a 9-min gradient using 0.1% TFA (aq) and acetonitrile (MeCN). The extracts were analyzed at 240 and 280 nm, and quantified using external calibration with reference standards. The method met AOAC-based system suitability criteria (peak-area RSD ≤ 0.6%; retention time RSD ≤ 0.16%), including a resolution of 1.96, and delivered 11,364 ± 69 theoretical plates for the final peak. Calibration was linear acrossanalyte-dependent ranges spanning 5.5–520 μg/mL (R2 = 0.9996–0.99997), with LODs of 1.8–6.8 μg/mL and LOQs of 5.5–20.6 μg/mL. Recovery of pre-extraction oleuropein spikes was 96.7–101.6%, and three-day repeatability yielded RSDr values of 2.0–2.3%, depending on analyte. Overall, the results indicate that this UHPLC–PDA assay provides afast, selective, and practical option for routine, multi-analyte screening of powdered oliveextract products.
Related
- Metabolomic Profiling of Phenolic Compounds in Brazilian-Grown Olive Leaf Infusions and Ultrasound-Assisted Extracts
- Determination of the Optimal Mixture of Wall Materials for the Encapsulation of Cacao Pod Polyphenols by Spray Drying Using Response Surface Methodology
- Investigation of mulberry leaf and olive pomace extracts as green corrosion inhibitors for carbon steel protection: Experimental evaluation and process optimization
- Olive Leaf, Thyme and Green Walnut Husk Extracts as Functional Ingredients in Dairy Products: A Review.
- Mimetic tissue models for accurate lipid quantitation in fibrotic mouse heart by MALDI-MSI
BibTeX
@article{haas2026determination,
title = {{Determination and Quantitation of Key Secoiridoids and Polyphenols in Olive Extracts Using UHPLC-PDA}},
author = {Christian D. Haas and Yijin Tang and Ozan Kahraman and Christine Fields},
journal = {Molecules},
year = {2026},
month = nov,
doi = {10.3390/molecules31224111},
url = {https://www.mdpi.com/1420-3049/31/22/4111},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Determination and Quantitation of Key Secoiridoids and Polyphenols in Olive Extracts Using UHPLC-PDA
AU - Christian D. Haas
AU - Yijin Tang
AU - Ozan Kahraman
AU - Christine Fields
PY - 2026
DA - 2026/11/01
JO - Molecules
DO - 10.3390/molecules31224111
UR - https://www.mdpi.com/1420-3049/31/22/4111
AB - Olive extracts are increasingly used as concentrated, formulation-ready sources of olive phenolics and secoiridoids, yet many published chromatographic methods only focus on one or two identified compounds, limiting broader compositional screening and producttoproduct differentiation. To address this gap, a UHPLC–PDA method was developed for the simultaneous identification and quantitation of six key olive bioactives (hydroxytyrosol, tyrosol, oleuropein, oleuroside, oleacein, and oleocanthal) in powdered olive extract matrices. Samples were extracted in 80% acetonitrile using sonication and centrifugation, then separated on a C18 column with a 9-min gradient using 0.1% TFA (aq) and acetonitrile (MeCN). The extracts were analyzed at 240 and 280 nm, and quantified using external calibration with reference standards. The method met AOAC-based system suitability criteria (peak-area RSD ≤ 0.6%; retention time RSD ≤ 0.16%), including a resolution of 1.96, and delivered 11,364 ± 69 theoretical plates for the final peak. Calibration was linear acrossanalyte-dependent ranges spanning 5.5–520 μg/mL (R2 = 0.9996–0.99997), with LODs of 1.8–6.8 μg/mL and LOQs of 5.5–20.6 μg/mL. Recovery of pre-extraction oleuropein spikes was 96.7–101.6%, and three-day repeatability yielded RSDr values of 2.0–2.3%, depending on analyte. Overall, the results indicate that this UHPLC–PDA assay provides afast, selective, and practical option for routine, multi-analyte screening of powdered oliveextract products.
SN - 1420-3049
ER -