Stroke-Volume Response to a Standardized Fluid Challenge in Healthy Term Parturients: A Prospective Pilot Study.
- 1UOSD Anestesia in Ostetricia, Ginecologia e Terapia del Dolore 2, IRCCS Fondazione Policlinico Universitario Agostino Gemelli, 00168 Rome, Italy.
Abstract
Background: Hemodynamic adaptation to pregnancy is characterized by substantial interindividual variability, which may influence the cardiovascular response to fluid administration. However, the distribution of stroke-volume responses to a standardized fluid challenge in healthy term pregnancy remains poorly characterized. Objectives: This study aimed to characterize the magnitude and distribution of the stroke-volume response to a standardized crystalloid fluid challenge in healthy term parturients and to determine the proportion exceeding the protocol-defined 10% response threshold. Methods: This prospective interventional pilot study reports the hemodynamic response to the fluid-challenge component of a broader Ethics Committee-approved prospective interventional protocol involving a medical device. Participants were recruited by convenience sampling when an anesthesiologist involved in the study protocol was available. Healthy women with singleton term pregnancies scheduled for elective cesarean delivery were studied before spinal anesthesia in a 30° dorsal head-up supine position. After placement of an 18-G peripheral intravenous cannula and 5 min of ClearSight™ stabilization, a 250-mL crystalloid fluid challenge was administered under continuous non-invasive hemodynamic monitoring. Stroke volume (SV) was recorded every 20 s. Baseline SV was defined as the mean of the last three valid pre-challenge measurements, and the response was quantified as the maximum mean of three consecutive valid SV measurements during the first 10 min after challenge initiation. The percentage change in SV (ΔSV) was analyzed as a continuous variable; the protocol-defined 10% threshold was used to describe the proportion of participants exhibiting a response above this level. Results: Thirty-five participants had complete hemodynamic recordings suitable for the standardized analysis. The median ΔSV was 6.48% (IQR 1.21-13.91%). Thirteen of 35 participants exceeded the protocol-defined 10% threshold, corresponding to a proportion of 37.1% (95% CI 21.5-55.1%). Conclusions: Healthy term parturients exhibited substantial interindividual variability in SV response to a 250-mL crystalloid fluid challenge under the standardized study conditions. The continuous distribution of ΔSV and the uncertainty surrounding the proportion exceeding the protocol-defined threshold do not support interpretation of fluid responsiveness as a discrete physiological phenotype. These exploratory findings require confirmation in larger, prospectively powered studies before their potential relevance to individualized perioperative fluid management can be established. These findings provide exploratory physiological evidence of interindividual variability in maternal preload response and support further investigation of whether individualized hemodynamic assessment may contribute to personalized perioperative management in obstetric anesthesia.
Related
- Establishing a human co-infection challenge study of Streptococcus pneumoniae (Spn) and live attenuated influenza vaccine (LAIV) in older healthy adults: E xploring C o-infection with L ive Attenuated I nfluenza Vaccine and P neumococcu S in healthy old E r adults (ECLIPSE), a UK-based single-centre, single-blind randomised controlled trial
- Implementing Standardized Screening and Detection of Cognitive Impairment and Brain Pathologies in People with Spinal Cord Injury or Disease During First Rehabilitation: A Prospective Observational Study
- Quantitative Measurement of Hoover's Sign: Development of a Standardized Sensor, Interface Procedure, and Testing in Healthy Individuals
- Antiviral Activity and Safety of Molnupiravir in Healthy Participants Inoculated With Influenza Virus: A Phase 2a, Randomized, Human Challenge Trial.
- Widespread SARS-CoV-2 brain infection after intranasal challenge leads to innate and anti-viral immune response and interference with neuronal function in K18-hACE2 mice
BibTeX
@article{zanfini2026strokevolume,
title = {{Stroke-Volume Response to a Standardized Fluid Challenge in Healthy Term Parturients: A Prospective Pilot Study.}},
author = {Bruno Antonio Zanfini and Chiara Sonnino and Luciano Frassanito and Mariangela Di Muro and Matteo Biancone and Mariano Ciancia and Paolo Lazzaro and Francesco Mele and Francesca Tarantino and Gaetano Draisci},
journal = {Journal of personalized medicine},
year = {2026},
month = nov,
doi = {10.3390/jpm16110572},
url = {https://europepmc.org/article/MED/43082821},
note = {CC BY},
}
RIS
TY - JOUR
TI - Stroke-Volume Response to a Standardized Fluid Challenge in Healthy Term Parturients: A Prospective Pilot Study.
AU - Bruno Antonio Zanfini
AU - Chiara Sonnino
AU - Luciano Frassanito
AU - Mariangela Di Muro
AU - Matteo Biancone
AU - Mariano Ciancia
AU - Paolo Lazzaro
AU - Francesco Mele
AU - Francesca Tarantino
AU - Gaetano Draisci
PY - 2026
DA - 2026/11/06
JO - Journal of personalized medicine
DO - 10.3390/jpm16110572
UR - https://europepmc.org/article/MED/43082821
AB - Background: Hemodynamic adaptation to pregnancy is characterized by substantial interindividual variability, which may influence the cardiovascular response to fluid administration. However, the distribution of stroke-volume responses to a standardized fluid challenge in healthy term pregnancy remains poorly characterized. Objectives: This study aimed to characterize the magnitude and distribution of the stroke-volume response to a standardized crystalloid fluid challenge in healthy term parturients and to determine the proportion exceeding the protocol-defined 10% response threshold. Methods: This prospective interventional pilot study reports the hemodynamic response to the fluid-challenge component of a broader Ethics Committee-approved prospective interventional protocol involving a medical device. Participants were recruited by convenience sampling when an anesthesiologist involved in the study protocol was available. Healthy women with singleton term pregnancies scheduled for elective cesarean delivery were studied before spinal anesthesia in a 30° dorsal head-up supine position. After placement of an 18-G peripheral intravenous cannula and 5 min of ClearSight™ stabilization, a 250-mL crystalloid fluid challenge was administered under continuous non-invasive hemodynamic monitoring. Stroke volume (SV) was recorded every 20 s. Baseline SV was defined as the mean of the last three valid pre-challenge measurements, and the response was quantified as the maximum mean of three consecutive valid SV measurements during the first 10 min after challenge initiation. The percentage change in SV (ΔSV) was analyzed as a continuous variable; the protocol-defined 10% threshold was used to describe the proportion of participants exhibiting a response above this level. Results: Thirty-five participants had complete hemodynamic recordings suitable for the standardized analysis. The median ΔSV was 6.48% (IQR 1.21-13.91%). Thirteen of 35 participants exceeded the protocol-defined 10% threshold, corresponding to a proportion of 37.1% (95% CI 21.5-55.1%). Conclusions: Healthy term parturients exhibited substantial interindividual variability in SV response to a 250-mL crystalloid fluid challenge under the standardized study conditions. The continuous distribution of ΔSV and the uncertainty surrounding the proportion exceeding the protocol-defined threshold do not support interpretation of fluid responsiveness as a discrete physiological phenotype. These exploratory findings require confirmation in larger, prospectively powered studies before their potential relevance to individualized perioperative fluid management can be established. These findings provide exploratory physiological evidence of interindividual variability in maternal preload response and support further investigation of whether individualized hemodynamic assessment may contribute to personalized perioperative management in obstetric anesthesia.
SN - 2075-4426
ER -