Skip to content
DraconiticResearch
Search Sources API
277,308 studies31 sourcesUpdated 37 min ago
Peer-reviewedCC BY 4.0European Heart Journal. Case Reports

Successful atrial leadless pacemaker implantation in an 11-year-old with congenital sinus node dysfunction: a case report

Abstract

Background: Sinus node dysfunction (SND) is rare in the paediatric population. Leadless atrial pacing represents a novel therapeutic option. To our knowledge, this case represents the youngest reported patient to receive an atrial leadless pacemaker (AVEIR AR). While ventricular leadless pacing has been described in children, atrial leadless pacing experience in this population remains extremely limited.

Case summary: An 11-year-old boy with lifelong bradycardia documented since fetal life presented with exertional dyspnoea and recurrent syncopal episodes. Electrocardiography revealed nodal rhythm without sinus activity. Electrophysiological evaluation demonstrated a corrected sinus node recovery time of 4800 ms and absence of chronotropic response to intravenous atropine (0.04 mg/kg IV). The patient met Class I criteria for permanent pacemaker implantation according to current paediatric pacing consensus recommendations, given symptomatic SND with chronotropic incompetence. An AVEIR AR leadless pacemaker was successfully implanted at the base of the right atrial appendage with optimal electrical parameters. No procedural or 18-month follow-up complications were observed.

Discussion: This case demonstrates procedural feasibility of atrial leadless pacing in a carefully selected paediatric patient, with encouraging mid-term follow-up. Larger studies are required to establish long-term safety and clinical outcomes.

Related

  1. Successful Bailout Retrieval of an Active‐Fixation Atrial Leadless Pacemaker Following Suspected Tissue Entrapment During Repositioning
    Toshiya Yoshida, Akira Kasagawa, Daisuke Togashi +2
    Journal of arrhythmiaPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Multiple right ventricular pseudoaneurysms after helix-fixation leadless pacemaker implantation.
    Kosuke Hirose, Satoshi Oka, Nobuhiko Ueda +3
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Challenging case of leadless pacemaker implantation for a patient with left-sided inferior vena cava.
    Yuki Tanaka, Masaru Yamaki, Yoshifumi Mizuguchi +1
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Internal jugular vein approach facilitating second leadless pacemaker implantation after battery depletion
    Nobuhiko Ueda, Kohei Ishibashi, Akinori Wakamiya +2
    Journal of Cardiology CasesPeer-reviewedLicence not statedFull textCardiovascular medicinePMC
  5. Direct-visualization implantation of an atrial leadless pacemaker at tricuspid valve surgery.
    Pejman Mansouri, Shelief Y Robbins-Juarez, Francis Hartge +2
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{chipaccasani2026successful,
  title = {{Successful atrial leadless pacemaker implantation in an 11-year-old with congenital sinus node dysfunction: a case report}},
  author = {Fredy Chipa-Ccasani and José Cruzalegui and Bosco Moscoso and José María Tolosana and Georgia Sarquella-Brugada},
  journal = {European Heart Journal. Case Reports},
  year = {2026},
  month = oct,
  doi = {10.1093/ehjcr/ytag805},
  url = {https://doi.org/10.1093/ehjcr/ytag805},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Successful atrial leadless pacemaker implantation in an 11-year-old with congenital sinus node dysfunction: a case report
AU  - Fredy Chipa-Ccasani
AU  - José Cruzalegui
AU  - Bosco Moscoso
AU  - José María Tolosana
AU  - Georgia Sarquella-Brugada
PY  - 2026
DA  - 2026/10/30
JO  - European Heart Journal. Case Reports
DO  - 10.1093/ehjcr/ytag805
UR  - https://doi.org/10.1093/ehjcr/ytag805
AB  - Background: Sinus node dysfunction (SND) is rare in the paediatric population. Leadless atrial pacing represents a novel therapeutic option. To our knowledge, this case represents the youngest reported patient to receive an atrial leadless pacemaker (AVEIR AR). While ventricular leadless pacing has been described in children, atrial leadless pacing experience in this population remains extremely limited.  Case summary: An 11-year-old boy with lifelong bradycardia documented since fetal life presented with exertional dyspnoea and recurrent syncopal episodes. Electrocardiography revealed nodal rhythm without sinus activity. Electrophysiological evaluation demonstrated a corrected sinus node recovery time of 4800 ms and absence of chronotropic response to intravenous atropine (0.04 mg/kg IV). The patient met Class I criteria for permanent pacemaker implantation according to current paediatric pacing consensus recommendations, given symptomatic SND with chronotropic incompetence. An AVEIR AR leadless pacemaker was successfully implanted at the base of the right atrial appendage with optimal electrical parameters. No procedural or 18-month follow-up complications were observed.  Discussion: This case demonstrates procedural feasibility of atrial leadless pacing in a carefully selected paediatric patient, with encouraging mid-term follow-up. Larger studies are required to establish long-term safety and clinical outcomes.
SN  - 2514-2119
ER  -