Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 43 min ago
PreprintCC0arXiv

Continuous perception and adaptive metrics for scalable structure refinement

Abstract

We present a geometry-refinement workflow that adapts to the cost of an energy--gradient evaluation and the reliability of molecular topology. An initial Cartesian calculation and continuous bonding diagnostics determine whether to begin in projected Cartesian coordinates or in chemically adapted internal coordinates. Chemical perception generates local redundant measurements; sparse rank and conditioning tests combine them into nonredundant, symmetry-adapted coordinates; and a common optimizer uses the selected representation with resident or external calculators. For inexpensive gradients, the projected Cartesian route limits coordinate overhead; a single monitored internal-coordinate step can then provide chemical interpretability. When gradients are costly and topology is certified, symmetry-adapted internal coordinates reduce expensive energy--gradient calls. A quadraticized map improves localized anharmonic cases, while mixed Cartesian/internal charts cover uncertain or complex topologies. Local sparse operators and resident force-field and tight-binding calculators extend both routes to large systems. The same Cartesian calculator contract supports multilevel energy and gradient composition. The measured coordinate pipeline and recurrent resident tight-binding update show near-linear scaling over the tested size ranges; this statement applies to those qualified components, not to arbitrary electronic-structure calculations or cold starts. For certified, directly separable internal charts, the optimizer can use chemically designed Morse or Gaussian maps to quadraticize the local step problem. The quadraticized branch uses a short geometry-local history, while delocalized charts remain unchanged. This reduces iterations in difficult minima without changing the electronic potential or coordinate chart.

Related

  1. Uncertainty-Driven Self-Refinement of Adaptive Kolmogorov-Arnold Networks for Fitting Nonadiabatic Potential Energy Surface
    Jinke Yu, Xingyu Zhang, Qingyong Meng
    arXivPreprintarXiv licenceFull textPhysical chemistryarXiv
  2. Scalable Synthesis and Processing of Porous Organic Polymers for Continuous-Flow Noble Metal Recycling and Catalysis
    Zhong Li, Michelle Åhlén, Yayu Yan +4
    ChemRxivPreprintCC BYMaterials & polymersChemRxiv
  3. AutoSolveX: automated batch structure solution, initial refinement and guest screening from diffraction data
    Sofiia Butonova, Yinlin Chen, Xiaodong Zou
    ChemRxivPreprintCC BYFull textInorganic & organometallic chemistryChemRxiv
  4. Sisyphus: A Topology-Compiled Physiologically Based Pharmacokinetic Platform with Structure-Only Input and Bayesian Parameter Refinement
    Jae Min Yoon
    ChemRxivPreprintCC BYFull textGeneral chemistryChemRxiv
  5. PARAM-DOCK: An Integrated Framework for Parallel Multi-Protein–Multi-Ligand Docking and Scoring for Scalable Structure-Based Drug Discovery
    Samarth Kittad, Mallikarjunachari Uppuladinne, Aneesh Kotipalli +3
    ChemRxivPreprintCC BYFull textGeneral chemistryChemRxiv
BibTeX
@misc{barone2026continuous,
  title = {{Continuous perception and adaptive metrics for scalable structure refinement}},
  author = {Vincenzo Barone},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.25849},
  eprint = {2609.25849},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.25849},
  note = {CC0},
}
RIS
TY  - UNPB
TI  - Continuous perception and adaptive metrics for scalable structure refinement
AU  - Vincenzo Barone
PY  - 2026
DA  - 2026/09/22
PB  - arXiv
DO  - 10.48550/arxiv.2609.25849
UR  - https://arxiv.org/abs/2609.25849
AB  - We present a geometry-refinement workflow that adapts to the cost of an energy--gradient evaluation and the reliability of molecular topology. An initial Cartesian calculation and continuous bonding diagnostics determine whether to begin in projected Cartesian coordinates or in chemically adapted internal coordinates. Chemical perception generates local redundant measurements; sparse rank and conditioning tests combine them into nonredundant, symmetry-adapted coordinates; and a common optimizer uses the selected representation with resident or external calculators. For inexpensive gradients, the projected Cartesian route limits coordinate overhead; a single monitored internal-coordinate step can then provide chemical interpretability. When gradients are costly and topology is certified, symmetry-adapted internal coordinates reduce expensive energy--gradient calls. A quadraticized map improves localized anharmonic cases, while mixed Cartesian/internal charts cover uncertain or complex topologies. Local sparse operators and resident force-field and tight-binding calculators extend both routes to large systems. The same Cartesian calculator contract supports multilevel energy and gradient composition. The measured coordinate pipeline and recurrent resident tight-binding update show near-linear scaling over the tested size ranges; this statement applies to those qualified components, not to arbitrary electronic-structure calculations or cold starts. For certified, directly separable internal charts, the optimizer can use chemically designed Morse or Gaussian maps to quadraticize the local step problem. The quadraticized branch uses a short geometry-local history, while delocalized charts remain unchanged. This reduces iterations in difficult minima without changing the electronic potential or coordinate chart.
ER  -