Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 46 min ago
Peer-reviewedCC BY 4.0Quantum

Below-shot-noise capacity in phase estimation using nonlinear interferometers

7 affiliations
  1. 1Technische Universität Darmstadt, Fachbereich Physik, Institut für Angewandte Physik, Schloßgartenstr. 7, 64289 Darmstadt, Germany
  2. 2Imperial College London, Department of Physics, 1 Prince Consort Road, SW7 2AZ London, United Kingdom
  3. 3University of Oxford, Department of Physics, Parks Road, OX1 3PU Oxford, United Kingdom
  4. 4ICFO – Institut de Ciències Fotòniques, The Barcelona Institute of Science and Technology, 08860 Castelldefels, Spain
  5. 5Technische Universität Darmstadt, Fachbereich Physik, Institut für Angewandte Physik, Otto-Berndt-Straße 3, 64287 Darmstadt, Germany
  6. 6Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena, Germany
  7. 7Department of Signal Theory and Communications, Universitat Politecnica de Catalunya, 08034 Barcelona, Spain

Abstract

Over the past decade, several schemes for imaging and sensing based on nonlinear interferometers have been proposed and demonstrated experimentally. These interferometers exhibit two main advantages. First, they enable probing a sample at a chosen wavelength while detecting light at a different wavelength with high efficiency (bicolor quantum imaging and sensing with undetected light). Second, they can show quantum-enhanced sensitivities below the shot-noise limit, potentially reaching Heisenberg-limited precision in parameter estimation. Here, we compare three quantum-imaging configurations using only easily accessible intensity-based measurements for phase estimation: a Yurke-type SU(1,1) interferometer, a Mandel-type induced-coherence interferometer, and a hybrid scheme that continuously interpolates between them. While an ideal Yurke interferometer can exhibit Heisenberg scaling, this advantage is known to be fragile under realistic detection constraints and in the presence of loss. We demonstrate that differential intensity detection in the Mandel interferometer provides the highest and most robust phase sensitivity among the considered schemes, reaching but not surpassing the shot-noise limit, even in the presence of loss. Intensity measurements in a Yurke-type configuration can achieve genuine sub-shot-noise sensitivity under balanced losses and moderate gain; however, their performance degrades in realistic high-gain regimes. Consequently, in this regime, the Mandel configuration with differential detection outperforms the Yurke-type setup and constitutes the most robust approach for phase estimation.

Related

  1. Variable-Projection Spectral Demodulation of Fabry–Pérot Interferometers with Joint Background Estimation
    Yihang Li, Zhihang Zhang, Jun Wang +4
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  2. Impact of Correlated Test-Mass Noise on Stochastic Gravitational-Wave Background Searches with Space-Based Interferometers
    Jing-yi Wu, Yong Tang
    arXivPreprintCC BY 4.0Full textGravitation & general relativityarXiv
  3. Photon-Pair Advantage for Dissipative Parameter Estimation in Whispering-Gallery-Mode Interferometers
    Elnaz Darsheshdar, Callum Jones, Seyed Mostafa Moniri +3
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
  4. Nonlinear amplification of classical intensity noise and its impact on 𝑔² -measurements
    Rafael Winkler, Nikolai Semenov, Denitsa Baykusheva
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  5. To 𝒫 𝒯 or not to 𝒫 𝒯 : Noise-induced escape and nonlinear-damping stabilization in a parity-time dimer
    Richelle Jade L. Tuquero, Kilian Seibold, Oded Zilberberg
    Physical Review ResearchPeer-reviewedCC BY 4.0Atomic, molecular & optical physicsCrossref
BibTeX
@article{oglialoro2026belowshotnoise,
  title = {{Below-shot-noise capacity in phase estimation using nonlinear interferometers}},
  author = {Cristofero Oglialoro and Gerard J. Machado and Felix Farsch and Daniel F. Urrego and Alejandra A. Padilla and Raj B. Patel and Ian A. Walmsley and Markus Gräfe and Juan P. Torres and Enno Giese},
  journal = {Quantum},
  year = {2026},
  month = nov,
  doi = {10.22331/q-2026-11-18-2272},
  url = {https://quantum-journal.org/papers/q-2026-11-18-2272/},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Below-shot-noise capacity in phase estimation using nonlinear interferometers
AU  - Cristofero Oglialoro
AU  - Gerard J. Machado
AU  - Felix Farsch
AU  - Daniel F. Urrego
AU  - Alejandra A. Padilla
AU  - Raj B. Patel
AU  - Ian A. Walmsley
AU  - Markus Gräfe
AU  - Juan P. Torres
AU  - Enno Giese
PY  - 2026
DA  - 2026/11/18
JO  - Quantum
DO  - 10.22331/q-2026-11-18-2272
UR  - https://quantum-journal.org/papers/q-2026-11-18-2272/
AB  - Over the past decade, several schemes for imaging and sensing based on nonlinear interferometers have been proposed and demonstrated experimentally. These interferometers exhibit two main advantages. First, they enable probing a sample at a chosen wavelength while detecting light at a different wavelength with high efficiency (bicolor quantum imaging and sensing with undetected light). Second, they can show quantum-enhanced sensitivities below the shot-noise limit, potentially reaching Heisenberg-limited precision in parameter estimation. Here, we compare three quantum-imaging configurations using only easily accessible intensity-based measurements for phase estimation: a Yurke-type SU(1,1) interferometer, a Mandel-type induced-coherence interferometer, and a hybrid scheme that continuously interpolates between them. While an ideal Yurke interferometer can exhibit Heisenberg scaling, this advantage is known to be fragile under realistic detection constraints and in the presence of loss. We demonstrate that differential intensity detection in the Mandel interferometer provides the highest and most robust phase sensitivity among the considered schemes, reaching but not surpassing the shot-noise limit, even in the presence of loss. Intensity measurements in a Yurke-type configuration can achieve genuine sub-shot-noise sensitivity under balanced losses and moderate gain; however, their performance degrades in realistic high-gain regimes. Consequently, in this regime, the Mandel configuration with differential detection outperforms the Yurke-type setup and constitutes the most robust approach for phase estimation.
SN  - 2521-327X
ER  -