Skip to content
DraconiticResearch
Search Sources API
276,911 studies31 sourcesUpdated 2 min ago
Peer-reviewedCC BYClinical case reports

Case Report: Nursing Experience With Ultrasound-Guided PICC Catheterization in an Extremely Severe Alcohol Burn Patient.

1 more authors
5 affiliations
  1. 1Department of Oncology The Fourth Medical Center of PLA General Hospital Beijing China.
  2. 2Department of Nursing Hainan Hospital of Chinese PLA General Hospital Hainan China.
  3. 3Senior Department of Oncology The Fifth Medical Center of PLA General Hospital Beijing China.
  4. 4Department of Otorhinolaryngology-Head and Neck Surgery The Fourth Medical Center of PLA General Hospital Beijing China.
  5. 5Department of Thoracic Surgery The Fourth Medical Center of PLA General Hospital Beijing China.

Abstract

This article reports the experience of placing a PICC at a skin graft site after burns. The patient had 93% total body surface area burned. After skin transplantation, ultrasound-guided PICC catheterization was performed at the transplantation site, and the catheter was retained for 14 days without complications.

Related

  1. Archiving of Cardiac Catheterization Laboratory Procedures and Records of Radiation Exposure: A Single-Center Experience
    Pranab Jyoti Bhattacharyya, Maitreyee Bhattacharyya, Jahir Alam Choudhury
    CureusPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMCEurope PMC
  2. Ultrasound-guided infraclavicular axillary vein access for central venous catheterization: an evidence-informed narrative review
    Dan Li, Xueyi Shang, Liyuan Ren +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCEurope PMCPMC
  3. Ultrasound-guided distal versus conventional radial artery catheterization in older surgical patients: protocol for a randomized controlled noninferiority trial
    Long Zhang, Shunli Diao, Liangguang Zhang +1
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMCEurope PMC
  4. Promoting Safety in Alcohol Withdrawal Syndrome: A Proactive Nursing Process Framework
    Julie Anne C Comia, Elizabeth Card
    HCA Healthcare Journal of MedicinePeer-reviewedLicence not statedFull textNeurologyPMC
  5. Effects of Neurally Adjusted Ventilatory Assist on Lung Ultrasound Aeration and Diaphragmatic Function in Extremely Preterm Infants With Evolving or Established Bronchopulmonary Dysplasia.
    Anay Kulkarni, Justin Richards, Touqueer Fatima +3
    Pediatric pulmonologyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{li2026case,
  title = {{Case Report: Nursing Experience With Ultrasound-Guided PICC Catheterization in an Extremely Severe Alcohol Burn Patient.}},
  author = {Hui Li and Qiaoling Chen and Jie Gao and Jingwen Yang and Xiuli Sun and Mengwei Feng and Chao Yun and Ningning Liu and Yan Fu and Hui Zhao and Chenxi Li and Donghui Li and Tiesong Zhang},
  journal = {Clinical case reports},
  year = {2026},
  month = nov,
  doi = {10.1002/ccr3.73767},
  url = {https://europepmc.org/article/MED/43047597},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Case Report: Nursing Experience With Ultrasound-Guided PICC Catheterization in an Extremely Severe Alcohol Burn Patient.
AU  - Hui Li
AU  - Qiaoling Chen
AU  - Jie Gao
AU  - Jingwen Yang
AU  - Xiuli Sun
AU  - Mengwei Feng
AU  - Chao Yun
AU  - Ningning Liu
AU  - Yan Fu
AU  - Hui Zhao
AU  - Chenxi Li
AU  - Donghui Li
AU  - Tiesong Zhang
PY  - 2026
DA  - 2026/11/16
JO  - Clinical case reports
DO  - 10.1002/ccr3.73767
UR  - https://europepmc.org/article/MED/43047597
AB  - This article reports the experience of placing a PICC at a skin graft site after burns. The patient had 93% total body surface area burned. After skin transplantation, ultrasound-guided PICC catheterization was performed at the transplantation site, and the catheter was retained for 14 days without complications.
SN  - 2050-0904
ER  -