Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BY-NC-NDJournal of robotic surgery

Robot-assisted kidney autotransplantation across indications and platforms: a systematic review and sparse-event meta-analysis.

6 affiliations
  1. 1Urology Department, Institute of Medical Sciences, Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, Bursztynowa 2, Warsaw, 04-749, Poland. [email protected].
  2. 2Department of Urology and Urological Oncology, Multidisciplinary Hospital in Warsaw-Międzylesie, Bursztynowa 2, Warsaw, 04-749, Poland. [email protected].
  3. 3EAU Young Academic Urologists Robotics in Urology Working Group, Arnhem, The Netherlands. [email protected].
  4. 4Department of General, Oncological and Laparoscopic Urology, John Paul II Provincial Hospital in Bełchatów, Czapliniecka 123, Bełchatów, 97-400, Poland.
  5. 5Department of Urology and Urological Oncology, Multidisciplinary Hospital in Warsaw-Międzylesie, Bursztynowa 2, Warsaw, 04-749, Poland.
  6. 6Urology Department, Institute of Medical Sciences, Faculty of Medicine, Collegium Medicum, Cardinal Stefan Wyszyński University in Warsaw, Bursztynowa 2, Warsaw, 04-749, Poland.

Abstract

We assessed reported safety and clinical outcomes of robot-assisted kidney autotransplantation across indications, techniques and potentially overlapping reports. PubMed, Web of Science, Scopus, the Cochrane Central Register of Controlled Trials and ScienceDirect were searched through 22 August 2026. Primary human reports with robotic nephrectomy or implantation were eligible. Joanna Briggs Institute checklists assessed methodological limitations. Indication-specific findings were described separately. Series with at least five procedures and no identified overlap entered exploratory logistic-normal binomial models with profile-likelihood 95% confidence intervals (CIs). Eligibility and synthesis changes were post hoc. Twenty-three reports represented 17 putative report families; the exact number of unique patients could not be established. Two reports were not retrieved. Five series (125 patients) contributed primary data. Pooled proportions were 33.1% for any postoperative complication (95% CI 18.6-49.0%), 11.2% for major complications (5.5-21.1%), 3.2% for graft nonfunction or loss (0.8-7.3%) and 1.2% for conversion (< 0.1-5.0%; one event/86 patients; four reporting series). These estimates describe the included case mix, not a common risk across indications or techniques. Mortality reporting was incomplete. Symptom outcomes were heterogeneous, with persistent or worsened pain in some patients. Certainty in the pooled frequencies was very low. Published experience demonstrates technical feasibility in selected patients, with substantial uncertainty about safety and clinical benefit. Technical graft success does not establish symptom relief or comparative effectiveness. Standardized prospective data are needed. Registration: PROSPERO CRD42024610953.

Related

  1. Renal autotransplantation for pheochromocytoma involving the renal hilar vessels with kidney preservation: a case report and literature review
    Xiaodong Chen, Xiaodong Fan, Guobin Weng +1
    Frontiers in OncologyPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaCrossrefEurope PMCPMC
  2. Kidney Allograft Salvage by Autotransplantation for a Suspected Infectious Arterial Pseudoaneurysm in a Pediatric Recipient
    Zachary H. Rollins, Holly R. Caboti-Jones, Daniel H. Newton +4
    Case Reports in TransplantationPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  3. Prospective Clinical Evidence on Artificial Intelligence-Enabled Augmented and Mixed Reality in Robot-Assisted Prostate and Kidney Cancer Surgery: A Systematic Review.
    Gregory Harrison
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Digitally Guided Tooth Autotransplantation: A Systematic Review of Clinical, Radiographic and Operative Outcomes
    Abdullah Saleh Almutairi, Osama Mansour Alnoodaly, Sulaiman Mohammed Alrasheed +2
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  5. Artificial Intelligence-Guided Extracellular Vesicle Platforms for Diagnosis and Treatment of Chronic Kidney Disease: A Scoping Review and Future Directions
    Kumar Digvijay, Henrik Birn, Claudio Ronco
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{drobot2026robotassisted,
  title = {{Robot-assisted kidney autotransplantation across indications and platforms: a systematic review and sparse-event meta-analysis.}},
  author = {Rafał Bogdan Drobot and Mateusz Władysław Jobczyk and Jędrzej Jakub Skorupka and Artur Andrzej Antoniewicz},
  journal = {Journal of robotic surgery},
  year = {2026},
  month = nov,
  doi = {10.1007/s11701-026-04207-6},
  url = {https://europepmc.org/article/MED/43079159},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Robot-assisted kidney autotransplantation across indications and platforms: a systematic review and sparse-event meta-analysis.
AU  - Rafał Bogdan Drobot
AU  - Mateusz Władysław Jobczyk
AU  - Jędrzej Jakub Skorupka
AU  - Artur Andrzej Antoniewicz
PY  - 2026
DA  - 2026/11/25
JO  - Journal of robotic surgery
DO  - 10.1007/s11701-026-04207-6
UR  - https://europepmc.org/article/MED/43079159
AB  - We assessed reported safety and clinical outcomes of robot-assisted kidney autotransplantation across indications, techniques and potentially overlapping reports. PubMed, Web of Science, Scopus, the Cochrane Central Register of Controlled Trials and ScienceDirect were searched through 22 August 2026. Primary human reports with robotic nephrectomy or implantation were eligible. Joanna Briggs Institute checklists assessed methodological limitations. Indication-specific findings were described separately. Series with at least five procedures and no identified overlap entered exploratory logistic-normal binomial models with profile-likelihood 95% confidence intervals (CIs). Eligibility and synthesis changes were post hoc. Twenty-three reports represented 17 putative report families; the exact number of unique patients could not be established. Two reports were not retrieved. Five series (125 patients) contributed primary data. Pooled proportions were 33.1% for any postoperative complication (95% CI 18.6-49.0%), 11.2% for major complications (5.5-21.1%), 3.2% for graft nonfunction or loss (0.8-7.3%) and 1.2% for conversion (< 0.1-5.0%; one event/86 patients; four reporting series). These estimates describe the included case mix, not a common risk across indications or techniques. Mortality reporting was incomplete. Symptom outcomes were heterogeneous, with persistent or worsened pain in some patients. Certainty in the pooled frequencies was very low. Published experience demonstrates technical feasibility in selected patients, with substantial uncertainty about safety and clinical benefit. Technical graft success does not establish symptom relief or comparative effectiveness. Standardized prospective data are needed. Registration: PROSPERO CRD42024610953.
SN  - 1863-2483
SN  - 1863-2491
ER  -