Does the Microsoft HoloLens 2 improve implant positioning in total shoulder arthroplasty? A retrospective cohort analysis of radiographic and clinical outcomes.
- 1University of Texas Health Science Center at Houston, Department of Orthopedic Surgery, Houston, TX, USA.
- 2University of Texas Health Science Center at Houston, McGovern Medical School, Houston, TX, USA.
- 3ATI Physical Therapy, Institute for Musculoskeletal Advancement, Downers Grove, IL, USA.
Abstract
Background
Pre-operative three-dimensional (3D)-computed tomography (CT) planning is routinely used in primary shoulder arthroplasty to assess glenoid anatomy and template implants. Intraoperative mixed-reality (MR) holographic overlay of this plan may help improve implant position and long-term survivorship. The objective of this study was to determine whether MR visualization during anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) reduces reoperations and improves implant position compared with 3D-CT pre-operative planning alone.Methods
In this retrospective study of primary shoulder arthroplasties performed by a single surgeon between 2017 and 2024, reoperation rates and radiographic outcomes were compared between patients who received a 3D pre-operative plan alone (standard group) and those who additionally received MR visualization via the HoloLens 2 headset (Microsoft Corporation). Demographics, diagnosis, glenoid morphology, year of surgery, complications, and reoperations were recorded. Radiographic outcomes were humeral head center of rotation (COR) deviation from the anatomic circle of best fit for aTSA and glenoid baseplate rTSA angle for rTSA on Grashey radiographs. Unadjusted comparisons and adjusted analyses incorporating year of surgery were performed to account for the temporal adoption of MR visualization.Results
A total of 494 patients were identified (220 aTSA, 274 rTSA; 336 MR, 158 standard). Thirty-nine patients (7.9%) underwent reoperation, with no significant association between reoperation and surgical planning technique (standard n = 9, MR n = 30; P = .21). In aTSA, the MR group showed significantly better medial-lateral humeral head COR restoration (-0.30 ± 1.8 mm vs. -0.95 ± 2.0 mm, P = .009) but no difference in superior-inferior COR deviation (-0.33 ± 1.3 mm vs. -0.18 ± 1.6 mm, P = .24). In rTSA, baseplate inclination did not differ significantly between groups (1.35 ± 6.1° vs. 0.64 ± 6.8°, P = .22), nor did radiographic outlier rates. After adjustment for year of surgery, MR visualization was no longer significantly associated with medial-lateral COR deviation in aTSA.Conclusion
MR visualization was associated with a small unadjusted improvement in medial-lateral humeral head positioning in aTSA, but this difference was less than 1 mm and was no longer significant after adjustment for year of surgery. No differences were observed in superior-inferior humeral head positioning, baseplate inclination in rTSA, reoperation, or overall complication rates. These findings support the feasibility and short-term safety of MR visualization as an adjunct to CT-based 3D pre-operative planning, while longer-term studies are needed to determine whether MR improves clinical outcomes beyond standard 3D planning alone.
Related
- CPAK Phenotype Transitions After Mechanically Aligned Total Knee Arthroplasty: A Retrospective Cohort Study of Radiographic Patterns and 12-Month Patient-Reported Outcomes
- Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study
- Surgical approach and insert constraint are associated with small differences in patellar tilt after robotic‐assisted total knee arthroplasty: A retrospective comparative radiographic study
- Increased Accuracy of Acetabular Cup Positioning with an Automatic Impaction Device in Total Hip Arthroplasty
- Radiographic view strongly influences detection of humeral component migration after stemless shoulder arthroplasty
BibTeX
@article{holy2026does,
title = {{Does the Microsoft HoloLens 2 improve implant positioning in total shoulder arthroplasty? A retrospective cohort analysis of radiographic and clinical outcomes.}},
author = {Filip Holy and Madison Smith and Natalie L Myers and Nikhilesh Mehra and James Gregory},
journal = {JSES international},
year = {2026},
month = oct,
doi = {10.1016/j.jseint.2026.101805},
url = {https://europepmc.org/article/MED/43061477},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Does the Microsoft HoloLens 2 improve implant positioning in total shoulder arthroplasty? A retrospective cohort analysis of radiographic and clinical outcomes.
AU - Filip Holy
AU - Madison Smith
AU - Natalie L Myers
AU - Nikhilesh Mehra
AU - James Gregory
PY - 2026
DA - 2026/10/05
JO - JSES international
DO - 10.1016/j.jseint.2026.101805
UR - https://europepmc.org/article/MED/43061477
AB - Background Pre-operative three-dimensional (3D)-computed tomography (CT) planning is routinely used in primary shoulder arthroplasty to assess glenoid anatomy and template implants. Intraoperative mixed-reality (MR) holographic overlay of this plan may help improve implant position and long-term survivorship. The objective of this study was to determine whether MR visualization during anatomic total shoulder arthroplasty (aTSA) and reverse total shoulder arthroplasty (rTSA) reduces reoperations and improves implant position compared with 3D-CT pre-operative planning alone.Methods In this retrospective study of primary shoulder arthroplasties performed by a single surgeon between 2017 and 2024, reoperation rates and radiographic outcomes were compared between patients who received a 3D pre-operative plan alone (standard group) and those who additionally received MR visualization via the HoloLens 2 headset (Microsoft Corporation). Demographics, diagnosis, glenoid morphology, year of surgery, complications, and reoperations were recorded. Radiographic outcomes were humeral head center of rotation (COR) deviation from the anatomic circle of best fit for aTSA and glenoid baseplate rTSA angle for rTSA on Grashey radiographs. Unadjusted comparisons and adjusted analyses incorporating year of surgery were performed to account for the temporal adoption of MR visualization.Results A total of 494 patients were identified (220 aTSA, 274 rTSA; 336 MR, 158 standard). Thirty-nine patients (7.9%) underwent reoperation, with no significant association between reoperation and surgical planning technique (standard n = 9, MR n = 30; P = .21). In aTSA, the MR group showed significantly better medial-lateral humeral head COR restoration (-0.30 ± 1.8 mm vs. -0.95 ± 2.0 mm, P = .009) but no difference in superior-inferior COR deviation (-0.33 ± 1.3 mm vs. -0.18 ± 1.6 mm, P = .24). In rTSA, baseplate inclination did not differ significantly between groups (1.35 ± 6.1° vs. 0.64 ± 6.8°, P = .22), nor did radiographic outlier rates. After adjustment for year of surgery, MR visualization was no longer significantly associated with medial-lateral COR deviation in aTSA.Conclusion MR visualization was associated with a small unadjusted improvement in medial-lateral humeral head positioning in aTSA, but this difference was less than 1 mm and was no longer significant after adjustment for year of surgery. No differences were observed in superior-inferior humeral head positioning, baseplate inclination in rTSA, reoperation, or overall complication rates. These findings support the feasibility and short-term safety of MR visualization as an adjunct to CT-based 3D pre-operative planning, while longer-term studies are needed to determine whether MR improves clinical outcomes beyond standard 3D planning alone.
SN - 2666-6383
ER -