Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 1 min ago
Peer-reviewedCC BYBulletin of Pharmaceutical Sciences. Assiut University

Simultaneous quantification of Minoxidil and Dexpanthenol in topical solutions: Development and validation of a RP-HPLC procedure

  1. 1Department of Pharmaceutical Chemistry & Quality Control, Faculty of Pharmacy, University of Aleppo, Aleppo, Syria
  2. 2Department of Biochemistry & Microbiology, Faculty of Pharmacy, University of Aleppo, Aleppo, Syria

Abstract

One run, two analytes. This RP–HPLC–DAD assay method was validated in accordance with ICH Q2(R2) criteria for the simple and robust quantification of minoxidil (MXD) and dexpanthenol (DXP) in topical pharmaceutical solutions. Utilizing a BDS Hypersil C18 column with an isocratic system— a 20 mM phosphate buffer (pH 2.5) and methanol in a 75:25 (v/v) ratio, respectively, pumped at a 1.0 mL/min— the setup achieved clear separation between MXD and DXP. Detection was carried out at 230 nm for MXD and 210 nm for DXP, yielding retention times of 11.34 and 4.09 min, respectively, with resolution of 6.65. The method exhibited good linearity over the concentration ranges of 75–500 µg/mL for MXD and 100–650 µg/mL for DXP, with R2 values of 0.9989 and 0.9988, respectively. The LOD and LOQ were 21.17 and 64.15 µg/mL for MXD and 25.71 and 77.92 µg/mL for DXP, respectively. The method demonstrated satisfactory accuracy and precision, with recoveries ranging from 98.22% to 100.46% for MXD and from 98.42% to 101.05% for DXP, while the relative standard deviation (%RSD) values remained below 2%. The proposed method was successfully applied to commercial topical solutions, demonstrating its practical utility for regular quality assurance workflows.

Related

  1. Development of an LC–MS/MS Method for Simultaneous Quantification of Erythromycin A and Seven Metabolites: Initial Residue Profile in Salmon Muscle with Skin
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  2. HPTLC Method Development and Validation for Simultaneous Estimation of Rifaximin and Metronidazole Benzoate in Combined Tablet Dosage Form
    Vaishali Goswami, Rashmi Shukla, Bharti Patel +3
    International Journal of Drug Delivery TechnologyPeer-reviewedLicence not statedFull text5 citedAnalytical chemistryOpenAlex
  3. USP Standards for Dietary Ingredients Derived from Mate and Guayusa Leaves: A Quality by Design Approach to Method Development and Validation for the Simultaneous Determination of Methylxanthines and Hydroxycinnamoylquinic Acids
    Salika Jeelani, Greg Winter, Natalia Kouznetsova +1
    ACS OmegaPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryCrossrefPMC
  4. Analytical Method Development and Validation for the Quantification of Related Substances in Pantoprazole Gastro-Resistant Tablets by RP-HPLC: A Critical Review
    Abirami A, Prarthana J, Surya R +1
    International Journal of Research in Pharmaceutical SciencesPeer-reviewedCC BYFull textAnalytical chemistryDOAJ
  5. Development and validation of a novel candidate reference procedure for the quantification of 3-nitro-L-tyrosine, 3-monoiodo-L-tyrosine and 3,5-diiodo-L-tyrosine in urine by isotope dilution and LC-ESI-MS/MS
    Heli Potes-Rodriguez, Pablo Rodríguez-González, Juan Manuel Marchante-Gayon +6
    Microchemical JournalPeer-reviewedCC BY-NC-ND 4.0Full textAnalytical chemistryHAL
BibTeX
@article{sabouny2026simultaneous,
  title = {{Simultaneous quantification of Minoxidil and Dexpanthenol in topical solutions: Development and validation of a RP-HPLC procedure}},
  author = {Aya Sabouny and Ali Ibrahim and Saleh Trefi and Yaser Bitar},
  journal = {Bulletin of Pharmaceutical Sciences. Assiut University},
  year = {2026},
  month = oct,
  doi = {10.21608/bfsa.2026.525514.3290},
  url = {https://doi.org/10.21608/bfsa.2026.525514.3290},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Simultaneous quantification of Minoxidil and Dexpanthenol in topical solutions: Development and validation of a RP-HPLC procedure
AU  - Aya Sabouny
AU  - Ali Ibrahim
AU  - Saleh Trefi
AU  - Yaser Bitar
PY  - 2026
DA  - 2026/10/25
JO  - Bulletin of Pharmaceutical Sciences. Assiut University
DO  - 10.21608/bfsa.2026.525514.3290
UR  - https://doi.org/10.21608/bfsa.2026.525514.3290
AB  - One run, two analytes. This RP–HPLC–DAD assay method was validated in accordance with ICH Q2(R2) criteria for the simple and robust quantification of minoxidil (MXD) and dexpanthenol (DXP) in topical pharmaceutical solutions. Utilizing a BDS Hypersil C18 column with an isocratic system— a 20 mM phosphate buffer (pH 2.5) and methanol in a 75:25 (v/v) ratio, respectively, pumped at a 1.0 mL/min— the setup achieved clear separation between MXD and DXP. Detection was carried out at 230 nm for MXD and 210 nm for DXP, yielding retention times of 11.34 and 4.09 min, respectively, with resolution of 6.65. The method exhibited good linearity over the concentration ranges of 75–500 µg/mL for MXD and 100–650 µg/mL for DXP, with R2 values of 0.9989 and 0.9988, respectively. The LOD and LOQ were 21.17 and 64.15 µg/mL for MXD and 25.71 and 77.92 µg/mL for DXP, respectively. The method demonstrated satisfactory accuracy and precision, with recoveries ranging from 98.22% to 100.46% for MXD and from 98.42% to 101.05% for DXP, while the relative standard deviation (%RSD) values remained below 2%. The proposed method was successfully applied to commercial topical solutions, demonstrating its practical utility for regular quality assurance workflows.
SN  - 3009-7703
SN  - 1110-0052
ER  -