Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report.
- 1Department of Hemodialysis, General Hospital Zadar, 23000 Zadar, Croatia.
- 2Department of Nephrology, University Hospital Centre Zagreb, 10000 Zagreb, Croatia.
- 3Department of Dermatovenereology, General Hospital Zadar, 23000 Zadar, Croatia.
Abstract
Background: Dialyzer-associated hypersensitivity reactions are rare but potentially life-threatening complications of hemodialysis (HD). Their pathophysiology is heterogeneous. Methods: We report a 49-year-old patient with end-stage chronic kidney disease (CKD G5), severe secondary hyperparathyroidism, poorly controlled arterial hypertension, a long history of heavy smoking, severe coronary and valvular disease, reduced left ventricular ejection fraction, renal anemia, and chronic volume overload. Results: Shortly after initiation of HD with a polysulfone dialyzer (Diacap Pro), she repeatedly developed severe dyspnea, hypoxemia, and marked hypertensive responses. Similar reactions occurred after switching to a cellulose triacetate dialyzer (Sureflux), necessitating temporary conversion to peritoneal dialysis (PD). Progressive PD ultrafiltration failure and loss of residual kidney function eventually required a return to HD. Severe reactions recurred within 15-30 min of treatment despite premedication. During the most severe episode, the patient developed profound hypoxemia (SpO₂ 55%), severe hypertension (up to 240/130 mmHg), ventricular tachycardia, and cardiac arrest requiring successful cardiopulmonary resuscitation. Immunological evaluation demonstrated normal total IgE (17 U/mL), decreased C3 (0.76 g/L), markedly reduced total hemolytic complement activity (CH50, 18%), and elevated IL-6 (87.5 pg/mL). Chronic HD was successfully reinitiated using an FX CorAL dialyzer with a Helixone® hydro membrane. Since its introduction, no further hypersensitivity reactions have occurred, and corticosteroid, antihistamine, and bronchodilator premedication has been discontinued. This case demonstrates severe recurrent dialyzer-associated hypersensitivity with findings suggestive of complement involvement, complicated by cardiac arrest in a patient with markedly impaired cardiovascular reserve. Conclusions: Successful long-term treatment with a hydrophilic Helixone® dialyzer highlights the importance of individualized dialyzer selection in patients with severe hypersensitivity reactions.
Related
- Successful Use of Rituximab in Severe, Nonviral Cryoglobulinemic Vasculitis Complicated by Recurrent Infections and Macrophage Activation Syndrome: A Case Report
- Case Report: Examining the role of omalizumab as an adjunct in the management of recurrent trastuzumab-associated hypersensitivity reactions
- Monocyte-associated C1q upregulation and complement activation contribute to vascular endothelial and multi-organ injury in severe dengue
- JS09.5.A Neoadjuvant fractionated stereotactic radiotherapy with PD-1 blockade and GITR agonism is associated with prolonged survival and durable systemic immune activation in recurrent glioblastoma
- Ruxolitinib in IVIG-resistant kawasaki disease-associated macrophage activation syndrome complicated by a giant coronary artery aneurysm: a case report and narrative literature review
BibTeX
@article{klaric2026recurrent,
title = {{Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report.}},
author = {Dragan Klarić and Lea Katalinić and Marta Klarić},
journal = {Journal of personalized medicine},
year = {2026},
month = nov,
doi = {10.3390/jpm16110570},
url = {https://europepmc.org/article/MED/43082819},
note = {CC BY},
}
RIS
TY - JOUR
TI - Recurrent Dialyzer-Associated Hypersensitivity with Complement Activation Complicated by Cardiac Arrest: A Case Report.
AU - Dragan Klarić
AU - Lea Katalinić
AU - Marta Klarić
PY - 2026
DA - 2026/11/02
JO - Journal of personalized medicine
DO - 10.3390/jpm16110570
UR - https://europepmc.org/article/MED/43082819
AB - Background: Dialyzer-associated hypersensitivity reactions are rare but potentially life-threatening complications of hemodialysis (HD). Their pathophysiology is heterogeneous. Methods: We report a 49-year-old patient with end-stage chronic kidney disease (CKD G5), severe secondary hyperparathyroidism, poorly controlled arterial hypertension, a long history of heavy smoking, severe coronary and valvular disease, reduced left ventricular ejection fraction, renal anemia, and chronic volume overload. Results: Shortly after initiation of HD with a polysulfone dialyzer (Diacap Pro), she repeatedly developed severe dyspnea, hypoxemia, and marked hypertensive responses. Similar reactions occurred after switching to a cellulose triacetate dialyzer (Sureflux), necessitating temporary conversion to peritoneal dialysis (PD). Progressive PD ultrafiltration failure and loss of residual kidney function eventually required a return to HD. Severe reactions recurred within 15-30 min of treatment despite premedication. During the most severe episode, the patient developed profound hypoxemia (SpO₂ 55%), severe hypertension (up to 240/130 mmHg), ventricular tachycardia, and cardiac arrest requiring successful cardiopulmonary resuscitation. Immunological evaluation demonstrated normal total IgE (17 U/mL), decreased C3 (0.76 g/L), markedly reduced total hemolytic complement activity (CH50, 18%), and elevated IL-6 (87.5 pg/mL). Chronic HD was successfully reinitiated using an FX CorAL dialyzer with a Helixone® hydro membrane. Since its introduction, no further hypersensitivity reactions have occurred, and corticosteroid, antihistamine, and bronchodilator premedication has been discontinued. This case demonstrates severe recurrent dialyzer-associated hypersensitivity with findings suggestive of complement involvement, complicated by cardiac arrest in a patient with markedly impaired cardiovascular reserve. Conclusions: Successful long-term treatment with a hydrophilic Helixone® dialyzer highlights the importance of individualized dialyzer selection in patients with severe hypersensitivity reactions.
SN - 2075-4426
ER -