Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 52 min ago
PreprintarXiv licencearXiv

Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance

Abstract

Percutaneous needle insertion is a common practice in minimally invasive procedures whose clinical success depends on accurate needle placement. However, achieving the necessary precision is a challenge for manual operators. Robotic assistance can improve targeting accuracy and reduce operator dependence, but residual millimeter-scale errors persist because nominal kinematic models do not fully represent the physical manipulator. This paper presents a robust bound-constrained kinematic calibration method designed to improve positional accuracy for a 6-Degree-of-Freedom (6-DoF) robotic needle-guidance manipulator. The approach uses physically plausible parameter ranges to regularize a compact 19-parameter geometric identification model. By treating these bounds as active optimization constraints rather than mere numerical safeguards, the framework effectively mitigates parameter coupling and overfitting, ensuring highly stable parameter identification. In simulation, the proposed method reduced end-effector Root Mean Square Error (RMSE) from 3.422 mm to 0.690 mm (a 79.8% improvement). In benchtop hardware experiments, the calibrated model achieved sub-millimeter validation accuracy, including 0.865 mm RMSE in experimental trajectory validation and 0.610 mm RMSE in a coordinate-lattice verification task. These results demonstrate that physically constrained kinematic calibration can enhance robotic needle-targeting accuracy, establishing a high-precision foundation for future clinical applications.

Related

  1. Method for Constrained Computational Guidance and Control with Application to Hypersonic Entry
    Emily M. Palmer, Anil V. Rao
    arXivPreprintarXiv licenceFull textOptimisation & controlarXiv
  2. Constraint-Lifted Sector-Constrained Guidance for Rear-Approach Interception
    Jhon Manuel Portella Delgado, Dennis S Bernstein, Ankit Goel
    arXivPreprintCC BY-NC-ND 4.0Full textOptimisation & controlarXiv
  3. Constrained weak identification of Allen--Cahn free energies with surface-tension calibration
    Soobeen Jung, Hyunju Kim
    arXivPreprintarXiv licenceFull textNumerical analysis & scientific computingComputational physicsarXiv
  4. Beyond Expert Rankings: Contrast Calibration for Mixed-Precision MoE Quantization
    Renjie Xie, Juncheng Yang, Aoting Hu +5
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. Constrained Genetic-Algorithm-Based PID Gain Optimization for Servo Control of a Diverter Valve in a 200 kg Gravimetric Liquid Flow Calibration Module
    Basaldua-Olvera Isaí, Chavero-Navarrete Ernesto
    MathematicsPeer-reviewedCC BY 4.0General mathematicsCrossref
BibTeX
@misc{gollapudi2026physically,
  title = {{Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance}},
  author = {Prabhu Nithin Gollapudi and Andreas Maier and Franziska Mathis-Ullrich and Water Zhao and Jia Wang and Siming Bayer},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.41429},
  eprint = {2610.41429},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.41429},
}
RIS
TY  - UNPB
TI  - Physically Constrained Kinematic Calibration for High-Precision Robotic Needle Guidance
AU  - Prabhu Nithin Gollapudi
AU  - Andreas Maier
AU  - Franziska Mathis-Ullrich
AU  - Water Zhao
AU  - Jia Wang
AU  - Siming Bayer
PY  - 2026
DA  - 2026/10/30
PB  - arXiv
DO  - 10.48550/arxiv.2610.41429
UR  - https://arxiv.org/abs/2610.41429
AB  - Percutaneous needle insertion is a common practice in minimally invasive procedures whose clinical success depends on accurate needle placement. However, achieving the necessary precision is a challenge for manual operators. Robotic assistance can improve targeting accuracy and reduce operator dependence, but residual millimeter-scale errors persist because nominal kinematic models do not fully represent the physical manipulator. This paper presents a robust bound-constrained kinematic calibration method designed to improve positional accuracy for a 6-Degree-of-Freedom (6-DoF) robotic needle-guidance manipulator. The approach uses physically plausible parameter ranges to regularize a compact 19-parameter geometric identification model. By treating these bounds as active optimization constraints rather than mere numerical safeguards, the framework effectively mitigates parameter coupling and overfitting, ensuring highly stable parameter identification. In simulation, the proposed method reduced end-effector Root Mean Square Error (RMSE) from 3.422 mm to 0.690 mm (a 79.8% improvement). In benchtop hardware experiments, the calibrated model achieved sub-millimeter validation accuracy, including 0.865 mm RMSE in experimental trajectory validation and 0.610 mm RMSE in a coordinate-lattice verification task. These results demonstrate that physically constrained kinematic calibration can enhance robotic needle-targeting accuracy, establishing a high-precision foundation for future clinical applications.
ER  -