Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 47 min ago
PreprintCC BY-SA 4.0arXiv

Implementing the EIT complete electrode model through Robin boundary conditions

Abstract

Objective. Medical electrical impedance tomography systems prescribe electrode currents. Accurate voltages, even on passive electrodes, require the complete electrode model (CEM), the most accurate model known for skin electrodes. Its current constraints specify total electrode currents, whereas standard finite element boundary interfaces impose local conditions. We describe how to implement the CEM through Robin boundary conditions, which are available in standard FEM packages. Approach. Prescribed electrode potentials give Robin problems whose unit-potential responses define an electrode transadmittance matrix. We prove equivalence to the conventional augmented CEM and formalise the discrete energy, equivalence and reference arguments in Lean 4. Numerical comparisons use two-dimensional P1 finite elements in DOLFINx, FreeFEM, GetFEM, MFEM and NGSolve, with the same nodal reference potential as EIDORS. Main results. For identical assembled blocks, the two procedures have the same solution set whenever the Robin matrix is invertible. Across the five packages in dimensionless test cases, maximum absolute electrode-potential differences from EIDORS were below 5×10−13 (2692 nodes), and errors against an exact rational-arithmetic reference were below 1.1×10−13 (2535 nodes). Significance. Standard Robin solves and consistent electrode-current integration provide a portable route to the current-driven CEM, with current constraints enforced through a small electrode system.

Related

  1. Conditions for implementing projective measurements through continuous monitoring
    Therese Karmstrand, Franco Nori, Clemens Gneiting
    Physical Review ResearchPeer-reviewedPublisher termsAtomic, molecular & optical physicsCrossref
  2. Investigation of balance disorders through the clinical Sudden Stop Test: influence of the kinematics and the boundary conditions
    Daniel Baumgartner, Anne Charpiot, Manon Blaise
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  3. Instantaneous one-dimensional velocity measurements of gas flow field under low-pressure conditions based on femtosecond laser-extended electrode discharge
    Zheng Lu, Kun Li, Bo Li +1
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  4. Engineering Giant Thermoelectric Performance through Electrode-Coupling Geometry and Magnetic Flux in Quasiperiodic Su-Schrieffer-Heeger Rings
    Sridhar, Souvik Roy, Malay Bandyopadhyay
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  5. Complete set of bounded-from-below conditions for the A4-symmetric three-Higgs-doublet model
    Luís Lavoura, André Milagre
    arXivPreprintCC BY 4.0Full textHigh-energy & particle physicsarXiv
BibTeX
@misc{chen2026implementing,
  title = {{Implementing the EIT complete electrode model through Robin boundary conditions}},
  author = {Bing-Zhou Chen and Amelia Deakin and Andy Adler and Paul D. Ledger and William R. B. Lionheart},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.22944},
  eprint = {2610.22944},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.22944},
  note = {CC BY-SA 4.0},
}
RIS
TY  - UNPB
TI  - Implementing the EIT complete electrode model through Robin boundary conditions
AU  - Bing-Zhou Chen
AU  - Amelia Deakin
AU  - Andy Adler
AU  - Paul D. Ledger
AU  - William R. B. Lionheart
PY  - 2026
DA  - 2026/10/16
PB  - arXiv
DO  - 10.48550/arxiv.2610.22944
UR  - https://arxiv.org/abs/2610.22944
AB  - Objective. Medical electrical impedance tomography systems prescribe electrode currents. Accurate voltages, even on passive electrodes, require the complete electrode model (CEM), the most accurate model known for skin electrodes. Its current constraints specify total electrode currents, whereas standard finite element boundary interfaces impose local conditions. We describe how to implement the CEM through Robin boundary conditions, which are available in standard FEM packages. Approach. Prescribed electrode potentials give Robin problems whose unit-potential responses define an electrode transadmittance matrix. We prove equivalence to the conventional augmented CEM and formalise the discrete energy, equivalence and reference arguments in Lean 4. Numerical comparisons use two-dimensional P1 finite elements in DOLFINx, FreeFEM, GetFEM, MFEM and NGSolve, with the same nodal reference potential as EIDORS. Main results. For identical assembled blocks, the two procedures have the same solution set whenever the Robin matrix is invertible. Across the five packages in dimensionless test cases, maximum absolute electrode-potential differences from EIDORS were below 5×10^−13 (2692 nodes), and errors against an exact rational-arithmetic reference were below 1.1×10^−13 (2535 nodes). Significance. Standard Robin solves and consistent electrode-current integration provide a portable route to the current-driven CEM, with current constraints enforced through a small electrode system.
ER  -