Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BY-NC-NDArthroscopy techniques

Arthroscopic “Triple‐Beam” Biologic Augmentation of Massive Rotator Cuff Tears Using the Combined Long Head of Biceps Transposition and Autologous Palmaris Longus Tendon Bridging

  1. 1Department of Sports Medicine First Affiliated Hospital of Army Medical University Chongqing China

Abstract

The management of massive rotator cuff tears remains a substantial clinical challenge. Standard superior capsular reconstruction often fails to adequately restore the dynamic load‐transfer mechanics of the shoulder. Furthermore, direct repair of chronic, retracted tears is frequently associated with excessive tension, resulting in high rates of suture cut‐through and structural failure. To overcome these limitations, we describe an arthroscopic biological reconstruction technique termed the “Triple‐Beam” procedure. This approach combines transposition of the long head of the biceps tendon with augmentation using an autologous palmaris longus tendon bridge. The construct employs the transposed long head of the biceps tendon together with the anterior and posterior limbs of the palmaris longus graft to form a robust 3‐beam structure secured to the greater tuberosity. This design is intended to provide both static superior restraints to prevent superior humeral migration and dynamic load distribution, thereby reducing tension at the repair interface. As a cost‐effective, autologous strategy, this technique aims to improve biological healing and biomechanical stability in the management of massive rotator cuff tears.

Related

  1. Arthroscopic Biologic Meniscal Root Repair With Iliotibial Band Autograft Augmentation
    Tomasz Piontek, Szymon Rubczak, Patrick Bulinski +4
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  2. Biological Augmentation of Arthroscopic Partial‐Thickness Bursal‐Sided Rotator Cuff Repair Using Minced Autologous Glenohumeral Ligament Tissue Particles
    Hengzhi Liu, Xinji Wang, Huajie Mao +1
    Arthroscopy TechniquesPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  3. Surgical Technique for Arthroscopic Rotator Cuff Repair With All-Polyester Patch Augmentation.
    Brian Fliegel, Kaley Beall, Manik Dham +1
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. Arthroscopic Technique for Anterior Calcaneal Process Avulsion Fractures and Bifurcate Ligament Injuries Using Suture Tape Augmentation.
    Rodrigo Díaz-Fernández
    Arthroscopy techniquesPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCPMC
  5. Arthroscopic Subscapularis Augmentation for the Treatment of Bankart Lesions: A Narrative Review of Indications, Techniques, and Comparative Outcomes
    Jaewook Park, Jaesung Yoo
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
BibTeX
@article{zhang2026arthroscopic,
  title = {{Arthroscopic “Triple‐Beam” Biologic Augmentation of Massive Rotator Cuff Tears Using the Combined Long Head of Biceps Transposition and Autologous Palmaris Longus Tendon Bridging}},
  author = {ChenKe Zhang and ZunHan Liu and MoLong Chen and YunJiao Wang and Guo Zheng and Lin Ma},
  journal = {Arthroscopy techniques},
  year = {2026},
  month = oct,
  doi = {10.1002/atn2.70355},
  url = {https://europepmc.org/article/PMC/PMC13722084},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Arthroscopic “Triple‐Beam” Biologic Augmentation of Massive Rotator Cuff Tears Using the Combined Long Head of Biceps Transposition and Autologous Palmaris Longus Tendon Bridging
AU  - ChenKe Zhang
AU  - ZunHan Liu
AU  - MoLong Chen
AU  - YunJiao Wang
AU  - Guo Zheng
AU  - Lin Ma
PY  - 2026
DA  - 2026/10/30
JO  - Arthroscopy techniques
DO  - 10.1002/atn2.70355
UR  - https://europepmc.org/article/PMC/PMC13722084
AB  - The management of massive rotator cuff tears remains a substantial clinical challenge. Standard superior capsular reconstruction often fails to adequately restore the dynamic load‐transfer mechanics of the shoulder. Furthermore, direct repair of chronic, retracted tears is frequently associated with excessive tension, resulting in high rates of suture cut‐through and structural failure. To overcome these limitations, we describe an arthroscopic biological reconstruction technique termed the “Triple‐Beam” procedure. This approach combines transposition of the long head of the biceps tendon with augmentation using an autologous palmaris longus tendon bridge. The construct employs the transposed long head of the biceps tendon together with the anterior and posterior limbs of the palmaris longus graft to form a robust 3‐beam structure secured to the greater tuberosity. This design is intended to provide both static superior restraints to prevent superior humeral migration and dynamic load distribution, thereby reducing tension at the repair interface. As a cost‐effective, autologous strategy, this technique aims to improve biological healing and biomechanical stability in the management of massive rotator cuff tears.
SN  - 2212-6287
ER  -