Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 37 min ago
PreprintarXiv licencearXiv

Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators

Abstract

Beam monitoring detectors play an important role in experimental control and radiological protection by enabling the real-time characterization of particle and photon beams. They provide information on beam intensity, position, and scattering, helping to ensure measurement accuracy, protect sensitive detectors, and quantify stray radiation in the surrounding environment. In this work, a Geant4 simulation was developed to investigate the performance of an X-ray beam monitoring detector (BMD) composed of six hexagonal BC404 plastic scintillators arranged to provide high granularity, using a reflector with a realistic reflectivity of 93\%. Under the simulation conditions considered in this study, the detector exhibited an intrinsic time resolution of 100.8 ± 2.0~ps. The results indicated that only about 10\% of the incident photons interacted with the detector, suggesting that the proposed design could be used for beam characterization while minimally perturbing the primary beam. In addition, the X-ray multiplicity decreased with distance according to an inverse-square dependence. A backscatter study performed using a water phantom showed that approximately 6\% of the incident beam was detected as scattered radiation. These results suggest that the proposed detector may be a useful tool for X-ray beam characterization and for studies related to scatter radiation and radiological protection. Further experimental validation is required to confirm these findings.

Related

  1. Optical Characterization Measurements of Commercial Polyvinyltoluene Scintillators for Accurate Geant4 Detector Modeling
    Fergus Martin Huggins, Micah S. Johnson, Matthew Quinn Buckner
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  2. Detailed investigation on the Geant4 simulation of alpha particles in liquid scintillator detector
    Shiwen Xu, Shubing Liu, Zeyuan Yu
    arXivPreprintarXiv licenceFull textHigh-energy & particle physicsarXiv
  3. Dual-Function Organic Emitters for Plastic Scintillators Enabled by Integration of Photocatalytic Controlled Radical Polymerization and Sensitive X-Ray Detection
    Hong Chen, Guangli He, Ziyu Cui +7
    ChemRxivPreprintCC BYFull textApplied physics & instrumentationChemRxiv
  4. GEANT4-Based Comparative Study of Detector Response in Reduced and Fully Instrumented Silicon-Tungsten Sampling Calorimeter
    A. Laha, S. Choudhury, S. Muhuri +1
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  5. remage: a Geant4-based simulation framework for low-background experiments
    Toby Dixon, Eric Esch, Reyco Henning +4
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
BibTeX
@misc{fernandez2026geant4,
  title = {{Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators}},
  author = {C. H. Zepeda Fernández and E. Moreno Barbosa and J. M. Arredondo-Velázquez and L. F. Rebolledo-Herrera},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.16397},
  eprint = {2609.16397},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.16397},
}
RIS
TY  - UNPB
TI  - Geant4 Simulation of an X-ray Beam Monitoring Detector based on plastic scintillators
AU  - C. H. Zepeda Fernández
AU  - E. Moreno Barbosa
AU  - J. M. Arredondo-Velázquez
AU  - L. F. Rebolledo-Herrera
PY  - 2026
DA  - 2026/09/14
PB  - arXiv
DO  - 10.48550/arxiv.2609.16397
UR  - https://arxiv.org/abs/2609.16397
AB  - Beam monitoring detectors play an important role in experimental control and radiological protection by enabling the real-time characterization of particle and photon beams. They provide information on beam intensity, position, and scattering, helping to ensure measurement accuracy, protect sensitive detectors, and quantify stray radiation in the surrounding environment. In this work, a Geant4 simulation was developed to investigate the performance of an X-ray beam monitoring detector (BMD) composed of six hexagonal BC404 plastic scintillators arranged to provide high granularity, using a reflector with a realistic reflectivity of 93\%. Under the simulation conditions considered in this study, the detector exhibited an intrinsic time resolution of 100.8 ± 2.0~ps. The results indicated that only about 10\% of the incident photons interacted with the detector, suggesting that the proposed design could be used for beam characterization while minimally perturbing the primary beam. In addition, the X-ray multiplicity decreased with distance according to an inverse-square dependence. A backscatter study performed using a water phantom showed that approximately 6\% of the incident beam was detected as scattered radiation. These results suggest that the proposed detector may be a useful tool for X-ray beam characterization and for studies related to scatter radiation and radiological protection. Further experimental validation is required to confirm these findings.
ER  -