Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 55 min ago
Peer-reviewedCC BY 4.0Journal of Mass Spectrometry and Advances in the Clinical Lab

Enhanced Sensitivity in Free Thyroxine Measurement Using Equilibrium Dialysis and LC-MS/MS Coupled with Offline Anion-Exchange Solid-Phase Extraction

Abstract

INTRODUCTION: According to the free hormone hypothesis, only the unbound hormone fraction exerts biological effects. Diagnosis and monitoring of thyroid disorders often require the measurement of free thyroxine (fT4) by equilibrium dialysis, which is considered the gold-standard method for separating free hormones from biological samples. OBJECTIVES: Our objective was to reduce complexity and enhance the sensitivity of a liquid chromatography–tandem mass spectrometry method with online solid-phase extraction (SPE) for measuring fT4. METHODS: Serum aliquots of 200 µL were subjected to equilibrium dialysis. Post-dialysis, increases in analytical sensitivity and specificity were achieved using weak-anion-based SPE prior to liquid chromatographic separation with subsequent analyte detection by a high-sensitivity SCIEX Triple Quad™ 7500 mass spectrometer. RESULTS: Lower and upper limits of quantitation (LLOQ and ULOQ) were 0.1 and 10 ng/dL, respectively. Intra- and inter-day precision evaluated using four matrix-matched quality control samples (0.15, 2.09, 5.10, and 7.94 ng/dL) indicated <10% imprecision, showing excellent agreement with the previous validated method (slope = 1.022, r = 0.9927, bias = 4.01%, n = 123). Chromatograms exhibited a substantial improvement in the signal-to-noise ratio at the LLOQ. CONCLUSION: A complex liquid chromatographic separation with online trapping-column method was successfully transitioned to a simpler off-line SPE liquid chromatographic separation method. Incorporating SPE desalting and using the improved instrument sensitivity of the SCIEX Triple Quad™ 7500 mass spectrometer significantly improved the performance. A reduced injection volume allowed sample reanalysis, which is beneficial for pediatric samples. This method provides a superior analytical approach for clinical fT4 measurement.

Related

  1. Optimizing thyroxine supplementation for enhanced rabbit buck semen cryopreservation: impacts on oxidative status, apoptosis-related gene expression, and fertility.
    Mustafa Shukry, Maha S Salama, Mohey A Ashour +5
    Frontiers in veterinary sciencePeer-reviewedCC BYFull textObstetrics, gynaecology & paediatricsEurope PMCPMC
  2. Hybrid feature pyramid attention and capsule network (FpaNet+CapsNet) for enhanced spatial and contextual feature extraction for improved brain tumor segmentation
    Eman Abdullah Aldakheel, Mohammed Zakariah, Syed Umar Amin +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0NeurologyCrossref
  3. Effects of Multi-Frequency Ultrasound-Enhanced Subcritical Water on the Extraction of Phenolic Compounds from Rapeseed Meal.
    Xiaoai Wang, Sheeza Rasheed, Jingyu Wei +6
    Foods (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Single High-Sensitivity Cardiac Troponin Measurement to Rule-out/Rule-in Myocardial Infarction in the Emergency Department
    Anne Marie Dupuy, Yanis Gueche, Anne Sophie Bargnoux +4
    The Journal of Applied Laboratory MedicinePeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicineHAL
  5. Early-to-mid-pregnancy maternal free thyroxine and fetal growth velocity trajectories: evidence from a large prospective cohort
    Honglin Jiang, Zhe Mu, Yongzhou Liang +3
    BMC MedicinePeer-reviewedCC BY-NC-ND 4.0Endocrinology & metabolismCrossref
BibTeX
@article{ray2026enhanced,
  title = {{Enhanced Sensitivity in Free Thyroxine Measurement Using Equilibrium Dialysis and LC-MS/MS Coupled with Offline Anion-Exchange Solid-Phase Extraction}},
  author = {Julie A Ray and Kelly Doyle},
  journal = {Journal of Mass Spectrometry and Advances in the Clinical Lab},
  year = {2026},
  month = oct,
  doi = {10.21627/v8rdvz16},
  url = {https://doi.org/10.21627/v8rdvz16},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Enhanced Sensitivity in Free Thyroxine Measurement Using Equilibrium Dialysis and LC-MS/MS Coupled with Offline Anion-Exchange Solid-Phase Extraction
AU  - Julie A Ray
AU  - Kelly Doyle
PY  - 2026
DA  - 2026/10/26
JO  - Journal of Mass Spectrometry and Advances in the Clinical Lab
DO  - 10.21627/v8rdvz16
UR  - https://doi.org/10.21627/v8rdvz16
AB  - INTRODUCTION: According to the free hormone hypothesis, only the unbound hormone fraction exerts biological effects. Diagnosis and monitoring of thyroid disorders often require the measurement of free thyroxine (fT4) by equilibrium dialysis, which is considered the gold-standard method for separating free hormones from biological samples. OBJECTIVES: Our objective was to reduce complexity and enhance the sensitivity of a liquid chromatography–tandem mass spectrometry method with online solid-phase extraction (SPE) for measuring fT4. METHODS: Serum aliquots of 200 µL were subjected to equilibrium dialysis. Post-dialysis, increases in analytical sensitivity and specificity were achieved using weak-anion-based SPE prior to liquid chromatographic separation with subsequent analyte detection by a high-sensitivity SCIEX Triple Quad™ 7500 mass spectrometer. RESULTS: Lower and upper limits of quantitation (LLOQ and ULOQ) were 0.1 and 10 ng/dL, respectively. Intra- and inter-day precision evaluated using four matrix-matched quality control samples (0.15, 2.09, 5.10, and 7.94 ng/dL) indicated <10% imprecision, showing excellent agreement with the previous validated method (slope = 1.022, r = 0.9927, bias = 4.01%, n = 123). Chromatograms exhibited a substantial improvement in the signal-to-noise ratio at the LLOQ. CONCLUSION: A complex liquid chromatographic separation with online trapping-column method was successfully transitioned to a simpler off-line SPE liquid chromatographic separation method. Incorporating SPE desalting and using the improved instrument sensitivity of the SCIEX Triple Quad™ 7500 mass spectrometer significantly improved the performance. A reduced injection volume allowed sample reanalysis, which is beneficial for pediatric samples. This method provides a superior analytical approach for clinical fT4 measurement.
SN  - 2667-1468
SN  - 2667-145X
ER  -