Inter-floor interactions of single-sided ventilation and gaseous pollutant transmission in an isolated multi-story building

  1. 1School of Energy and Environment, Anhui University of Technology, Ma’anshan 243002, China
  2. 2School of Energy and Environment, Anhui University of Technology, Ma’anshan 243002, China; Corresponding author.
  3. 3State Key Laboratory of Green Building, Xi’an University of Architecture & Technology, Xi’an 710055, China

Abstract

Natural ventilation is crucial for ensuring indoor air quality and improving energy efficiency in multi-story buildings. This study employs CFD (Computational Fluid Dynamics) simulations to investigate the inter-floor interactions of pollutant source floor, opening location (windward/leeward), and ventilated floor combinations on ventilation efficiency and pollutant transmission in multi-story buildings under the SS2 (single-sided ventilation with two openings) ventilation type. Results show that when the pollutant is released on the bottom floor, the peak PFR (purging flow rate) on the leeward side occurs at the 4 th floor, while the peak PFR on the windward side occurs at the 3 rd floor. When the pollutant is released on the top floor, the highest PFR occurs at the 4 th (windward) and 6 th (leeward) floors. Leeward R k (re-entry ratio) increases exponentially with the height of pollutant released floor, demonstrating greater sensitivity than that of the windward side. When all floors are ventilated, leeward R k remains higher than the windward side. Bottom floor pollutants rise upward along the leeward façade and descend on the windward facade, whereas top floor pollutants disperse both upward and backward on the windward façade. The findings of this study deepen the understanding of inter-floor interactions of ventilation performance in multi-story buildings and may provide guidance for the suitable window opening behavior for better ventilation performance under pollutant source release.

Related

  1. Microplastics–Pollutant Interactions in Environmental Systems: Mechanisms, Ecological Effects, and Implications for Sustainable Management
    Lei Wu, Xuerong Zhou, Cui Lai +3
    MoleculesPeer-reviewedCC BY11 citedEnvironmental science & pollutionOpenAlex
  2. Environmentally Relevant Concentrations of Nanomaterials Drive Photochemical Production of Reactive Species and Pollutant Degradation in Surface Waters
    Joshua Quinn, Aidan McClure, Pierre Herckes +1
    Nature CommunicationsPeer-reviewedCC BY-NC-ND 4.0Full textHydrology & soilsCrossref
  3. Enhancing pollutant removal from contaminated soils using yield stress fluids as selective blocking agents
    Antonio Rodríguez de Castro, Amine Ben Abdelwahed, Henri Bertin
    Journal of Contaminant HydrologyPeer-reviewedLicence not stated9 citedEnvironmental science & pollutionHAL
  4. Carbon source and pollutant matching shapes microbial succession and removal regimes under electrochemical redox control
    Ruixiang Li, Yuxuan Wan, Guoliang Wang +5
    Communications Earth & EnvironmentPeer-reviewedCC BY-NC-ND 4.0Full textEnvironmental science & pollutionCrossref
  5. Removal and biodegradation of the pharmaceutical pollutant cortisone acetate by Scenedesmus obtusus under varying salinity conditions
    Zahra Derakhshan, Fahimeh Tavakoli, Mohammad Reza Samaei +5
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEnvironmental science & pollutionCrossref
BibTeX
@article{chen2026interfloor,
  title = {{Inter-floor interactions of single-sided ventilation and gaseous pollutant transmission in an isolated multi-story building}},
  author = {Mengying Chen and Jiangnan Gui and Huihong Yin and Jie Sun and Huaiyu Zhong and Songheng Wu},
  journal = {Energy and Built Environment},
  year = {2026},
  month = oct,
  doi = {10.1016/j.enbenv.2026.01.002},
  url = {https://doi.org/10.1016/j.enbenv.2026.01.002},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Inter-floor interactions of single-sided ventilation and gaseous pollutant transmission in an isolated multi-story building
AU  - Mengying Chen
AU  - Jiangnan Gui
AU  - Huihong Yin
AU  - Jie Sun
AU  - Huaiyu Zhong
AU  - Songheng Wu
PY  - 2026
DA  - 2026/10/30
JO  - Energy and Built Environment
DO  - 10.1016/j.enbenv.2026.01.002
UR  - https://doi.org/10.1016/j.enbenv.2026.01.002
AB  - Natural ventilation is crucial for ensuring indoor air quality and improving energy efficiency in multi-story buildings. This study employs CFD (Computational Fluid Dynamics) simulations to investigate the inter-floor interactions of pollutant source floor, opening location (windward/leeward), and ventilated floor combinations on ventilation efficiency and pollutant transmission in multi-story buildings under the SS2 (single-sided ventilation with two openings) ventilation type. Results show that when the pollutant is released on the bottom floor, the peak PFR (purging flow rate) on the leeward side occurs at the 4 th floor, while the peak PFR on the windward side occurs at the 3 rd floor. When the pollutant is released on the top floor, the highest PFR occurs at the 4 th (windward) and 6 th (leeward) floors. Leeward R k (re-entry ratio) increases exponentially with the height of pollutant released floor, demonstrating greater sensitivity than that of the windward side. When all floors are ventilated, leeward R k remains higher than the windward side. Bottom floor pollutants rise upward along the leeward façade and descend on the windward facade, whereas top floor pollutants disperse both upward and backward on the windward façade. The findings of this study deepen the understanding of inter-floor interactions of ventilation performance in multi-story buildings and may provide guidance for the suitable window opening behavior for better ventilation performance under pollutant source release.
SN  - 2666-1233
ER  -