Smartphone-based monitoring and algorithmic prediction of neonatal jaundice: integrated technology for improved outpatient care
4 affiliations
- 1Department of Neonatology, University Children's Hospital Regensburg (KUNO), Hospital St. Hedwig of the Order of St. John of God, University of Regensburg, Regensburg, Germany
- 2School of Life Sciences, University of Applied Sciences and Arts Northwestern Switzerland (FHNW), Muttenz, Switzerland
- 3Paediatric Pharmacology and Pharmacometrics, University Children's Hospital Basel (UKBB), University of Basel, Basel, Switzerland
- 4Paediatric Infectious Diseases and Vaccinology, University Children's Hospital Basel (UKBB), University of Basel, Basel, Switzerland
Abstract
AimPost-discharge identification and monitoring of neonatal jaundice remain challenging. The aim of this study was to analyse bilirubin predictions up to 10 days after birth and assess their relationship with smartphone-based optical screening in outpatient care.MethodsProspective observational study conducted from July to September 2023 in an academic perinatal centre. After discharge, parents used the Picterus® JP Jaundice Pro app with a colour calibration card to perform daily bilirubin measurements for up to 10 days. These measurements were compared with predictions from the BiliPredics algorithm.Results45 healthy neonates qualified for inclusion, of whom 44 had a total serum bilirubin (TSB) measurement. Homebased Picterus® JP measurements showed a significant correlation with TSB and aligned well with BiliPredics trajectories. Beyond the validated 144-hour (6 days) window, BiliPredics slightly overestimated bilirubin levels compared with Picterus® JP. No significant correlation was found between parents' subjective handling assessments and measurement outcomes.ConclusionCombining clinical decision-support tools such as BiliPredics with optical bilirubin measurements may offer a promising approach for discharge planning and home-based monitoring of neonatal jaundice throughout the course of hyperbilirubinemia.
Related
- Technology-integrated carbohydrate strategies to prevent exercise-induced hypoglycemia in type 1 diabetes: from continuous glucose monitoring and automated insulin delivery to artificial intelligence-driven decision support: a narrative review
- Smartphone-Based Simulation Training Improves ACLS Algorithmic Decision-Making and ECG Recognition in Emergency Medicine Residents: A Pilot Randomized Controlled Trial
- Retinal layer thickness prediction from smartphone fundus imaging for early glaucoma detection
- Monitoring multiple rib fractures using pulmonary electrical impedance tomography technology: correlation analysis of pulmonary ventilation changes
- 341 SMART G-Rex® & SensoRexTM technology for in-line, non-invasive, and real-time monitoring of TIL expansion
BibTeX
@article{dietz2026smartphonebased,
title = {{Smartphone-based monitoring and algorithmic prediction of neonatal jaundice: integrated technology for improved outpatient care}},
author = {Annika Dietz and Britta Steffens and Britta Steffens and Gilbert Koch and Anna Badura and Sven Wellmann and Ines Mack},
journal = {Frontiers in Pediatrics},
year = {2026},
month = nov,
doi = {10.3389/fped.2026.1977997},
url = {https://doi.org/10.3389/fped.2026.1977997},
note = {CC BY},
}
RIS
TY - JOUR
TI - Smartphone-based monitoring and algorithmic prediction of neonatal jaundice: integrated technology for improved outpatient care
AU - Annika Dietz
AU - Britta Steffens
AU - Britta Steffens
AU - Gilbert Koch
AU - Anna Badura
AU - Sven Wellmann
AU - Ines Mack
PY - 2026
DA - 2026/11/11
JO - Frontiers in Pediatrics
DO - 10.3389/fped.2026.1977997
UR - https://doi.org/10.3389/fped.2026.1977997
AB - AimPost-discharge identification and monitoring of neonatal jaundice remain challenging. The aim of this study was to analyse bilirubin predictions up to 10 days after birth and assess their relationship with smartphone-based optical screening in outpatient care.MethodsProspective observational study conducted from July to September 2023 in an academic perinatal centre. After discharge, parents used the Picterus® JP Jaundice Pro app with a colour calibration card to perform daily bilirubin measurements for up to 10 days. These measurements were compared with predictions from the BiliPredics algorithm.Results45 healthy neonates qualified for inclusion, of whom 44 had a total serum bilirubin (TSB) measurement. Homebased Picterus® JP measurements showed a significant correlation with TSB and aligned well with BiliPredics trajectories. Beyond the validated 144-hour (6 days) window, BiliPredics slightly overestimated bilirubin levels compared with Picterus® JP. No significant correlation was found between parents' subjective handling assessments and measurement outcomes.ConclusionCombining clinical decision-support tools such as BiliPredics with optical bilirubin measurements may offer a promising approach for discharge planning and home-based monitoring of neonatal jaundice throughout the course of hyperbilirubinemia.
SN - 2296-2360
ER -