Association between the freezing of gait questionnaire score and wearable sensor-derived stride-length variability in Parkinson’s disease
- 1Department of Neurology, The First Affiliated Hospital of Soochow University
- 2Department of Neurology, The Affiliated Hospital of Xuzhou Medical University
- 3The First Clinical Medical College of Xuzhou Medical University, The Affiliated Hospital of Xuzhou Medical University
Abstract
Background: Freezing of gait (FOG) may not occur during brief clinical examinations in Parkinson’s disease (PD). The Chinese version of the Freezing of Gait Questionnaire (FOGQ-CH) captures patient-reported freezing burden, whereas wearable sensors quantify task-specific gait. We examined the association between the FOGQ-CH score and sensor-derived stride-length variability during the Timed Up and Go (TUG) test.
Methods: This retrospective single-center study included 218 participants with a same-day FOGQ-CH score and completed one practice trial plus two formal ordinary TUG trials. A serial-subtraction TUG was performed before formal testing in 217 participants. The primary outcome was the log-transformed mean of the two formal-trial stride-length variability values. Models were adjusted for age, sex, height, time since the recorded onset of PD, and device-recorded ON/OFF state. A same-day Movement Disorder Society–Unified Parkinson’s Disease Rating Scale, part III (MDS-UPDRS III), motor-severity proxy was available for 137 participants. Post-hoc sensitivity analyses examined gait asymmetry, speed, questionnaire score range, and extreme trial values.
Results: Each 5-point higher FOGQ-CH score was associated with 27.0% greater mean formal-trial stride-length variability (95% confidence interval [CI], 18.9%–35.6%; p < 0.001). The association was 26.9% (95% CI, 17.1%–37.5%) after additional motor-severity adjustment in 137 participants. In post-hoc analyses, adjustment for stride-length asymmetry reduced the full-cohort estimate to 9.9% (95% CI, 3.2%–17.1%). After joint adjustment for asymmetry, gait speed, and motor severity in 137 participants, the estimate was 4.9% (95% CI, −0.6% to 10.6%). Excluding participants with zero questionnaire scores or those with an unusually high single-trial variance had no significant effect on the primary association.
Conclusion: Higher FOGQ-CH scores were associated with greater sensor-derived stride-length variability during formal TUG assessment. The attenuation after accounting for asymmetry and speed suggests overlap with broader gait impairment. These data do not establish freezing specificity or added clinical utility. Further studies should include independent measurement validation, longer walking samples, and directly observed freezing events.
Related
- Effects of globus pallidus internus deep brain stimulation on freezing of gait in Parkinson's disease: a prospective short-term single-arm study
- Disease Duration Differentiates Freezing of Gait Response to Subthalamic and Nigral Stimulation for Parkinson's Disease in an Exploratory Multicenter Controlled Trial
- Inferior Frontal Gyrus Alterations in Freezing of Gait in Parkinson's Disease Without Evidence for Overall Hemispheric Lateralization: A Systematic Review and Activation Likelihood Estimation Meta-Analysis.
- NeuroEdge-X: Explainable Multi-Expert Fusion of Wearable Inertial Motion and Non-Motor Symptoms for Parkinson’s Disease Detection and Differential Diagnosis
- Wearable-measured 24-hour heart rate variability and neovascular age-related macular degeneration: a cross-sectional study
BibTeX
@article{zhu2026association,
title = {{Association between the freezing of gait questionnaire score and wearable sensor-derived stride-length variability in Parkinson’s disease}},
author = {Jienan Zhu and Chenxi Li and Liguo Dong and Wei Zhang and Qun Xue},
journal = {Frontiers in Neurology},
year = {2026},
month = nov,
doi = {10.3389/fneur.2026.2008818},
url = {https://www.frontiersin.org/articles/10.3389/fneur.2026.2008818/full},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Association between the freezing of gait questionnaire score and wearable sensor-derived stride-length variability in Parkinson’s disease
AU - Jienan Zhu
AU - Chenxi Li
AU - Liguo Dong
AU - Wei Zhang
AU - Qun Xue
PY - 2026
DA - 2026/11/18
JO - Frontiers in Neurology
DO - 10.3389/fneur.2026.2008818
UR - https://www.frontiersin.org/articles/10.3389/fneur.2026.2008818/full
AB - Background: Freezing of gait (FOG) may not occur during brief clinical examinations in Parkinson’s disease (PD). The Chinese version of the Freezing of Gait Questionnaire (FOGQ-CH) captures patient-reported freezing burden, whereas wearable sensors quantify task-specific gait. We examined the association between the FOGQ-CH score and sensor-derived stride-length variability during the Timed Up and Go (TUG) test. Methods: This retrospective single-center study included 218 participants with a same-day FOGQ-CH score and completed one practice trial plus two formal ordinary TUG trials. A serial-subtraction TUG was performed before formal testing in 217 participants. The primary outcome was the log-transformed mean of the two formal-trial stride-length variability values. Models were adjusted for age, sex, height, time since the recorded onset of PD, and device-recorded ON/OFF state. A same-day Movement Disorder Society–Unified Parkinson’s Disease Rating Scale, part III (MDS-UPDRS III), motor-severity proxy was available for 137 participants. Post-hoc sensitivity analyses examined gait asymmetry, speed, questionnaire score range, and extreme trial values. Results: Each 5-point higher FOGQ-CH score was associated with 27.0% greater mean formal-trial stride-length variability (95% confidence interval [CI], 18.9%–35.6%; p < 0.001). The association was 26.9% (95% CI, 17.1%–37.5%) after additional motor-severity adjustment in 137 participants. In post-hoc analyses, adjustment for stride-length asymmetry reduced the full-cohort estimate to 9.9% (95% CI, 3.2%–17.1%). After joint adjustment for asymmetry, gait speed, and motor severity in 137 participants, the estimate was 4.9% (95% CI, −0.6% to 10.6%). Excluding participants with zero questionnaire scores or those with an unusually high single-trial variance had no significant effect on the primary association. Conclusion: Higher FOGQ-CH scores were associated with greater sensor-derived stride-length variability during formal TUG assessment. The attenuation after accounting for asymmetry and speed suggests overlap with broader gait impairment. These data do not establish freezing specificity or added clinical utility. Further studies should include independent measurement validation, longer walking samples, and directly observed freezing events.
SN - 1664-2295
ER -