Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY 4.0Frontiers in Oncology

Central vein stenosis detected during a second peripherally inserted central catheter placement in a patient with recurrent breast cancer: a case report

Abstract

Central vein stenosis (CVS) can complicate peripherally inserted central catheter (PICC) placement by impeding catheter advancement and preventing achievement of an appropriate central tip position. On 23 January 2025, a 57-year-old female with recurrent right breast cancer was admitted for systemic anticancer treatment and required renewed long-term venous access. During a second PICC placement through the left basilic vein, catheter advancement was unexpectedly impeded, and venography confirmed left brachiocephalic vein stenosis with catheter coiling near the stenotic segment. A multidisciplinary team (MDT), including PICC specialist nurses, oncology physicians, cardiovascular surgeons, and ultrasound imaging experts, determined that further advancement across the left stenotic segment posed additional risk. The catheter was therefore withdrawn until the coiling resolved, leaving the tip in the left subclavian vein. After individualized assessment of the patient’s vascular anatomy, treatment requirements, and alternative vascular access options, the catheter was retained at this nonstandard tip position and managed with individualized anticoagulation and clinical surveillance. During approximately six months of follow-up, the patient experienced catheter dislodgement, but no clinically documented catheter-related thrombosis, infection, or drug extravasation occurred. The case highlights that unexpected resistance during PICC advancement may warrant assessment for central venous abnormalities even when peripheral veins appear patent. When CVS is encountered, catheter management should be individualized through MDT assessment, and retention of a PICC in a nonstandard tip position should be regarded as an exceptional strategy.

Related

  1. Initial peripherally inserted central catheter tip position accuracy by puncture arm and associated factors in female patients with breast cancer: A retrospective cohort study
    Min Zhang, Xue Liu, Lu Ruan +2
    The Journal of International Medical ResearchPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  2. Development and validation of a nomogram incorporating vascular morphological parameters for prediction of peripherally inserted central catheter-related thromboembolism in cancer patients.
    Guodong Wang, Yanfen Shen, Xinpeng Wang +7
    Thrombosis journalPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMCPMC
  3. Comparison of Peripherally Inserted Central Catheters versus Central Venous Catheters in a Medical Intensive Care Unit: A Single-Center Retrospective Study.
    Guo Long, Chao Jia, Huan Peng +1
    International journal of general medicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMCPMC
  4. A Case of Asymptomatic Carotid Artery Stenosis With Thumb‐Sized Calcification Detected on Panoramic Radiograph
    Kosei Shibata, Keiko Kaneko, Tatsuo Takaya +13
    Clinical case reportsPeer-reviewedCC BYFull textGeneral medicineEurope PMCPMCEurope PMC
  5. Cross-elbow stent placement for refractory arteriovenous fistula stenosis and chronic total occlusion in hemodialysis patients: a single-center retrospective cohort of 42 cases
    Yibiao Huang, Linnan Bai, Junnan Wu +2
    Renal FailurePeer-reviewedCC BY 4.0Full textGeneral medicinePMC
BibTeX
@article{wu2026central,
  title = {{Central vein stenosis detected during a second peripherally inserted central catheter placement in a patient with recurrent breast cancer: a case report}},
  author = {Hongrong Wu and Yanling Li and Jingwen Ding and Qun Huang and Xiaoli Chen and Linghong Tang},
  journal = {Frontiers in Oncology},
  year = {2026},
  month = nov,
  doi = {10.3389/fonc.2026.1881442},
  url = {https://www.frontiersin.org/articles/10.3389/fonc.2026.1881442},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Central vein stenosis detected during a second peripherally inserted central catheter placement in a patient with recurrent breast cancer: a case report
AU  - Hongrong Wu
AU  - Yanling Li
AU  - Jingwen Ding
AU  - Qun Huang
AU  - Xiaoli Chen
AU  - Linghong Tang
PY  - 2026
DA  - 2026/11/05
JO  - Frontiers in Oncology
DO  - 10.3389/fonc.2026.1881442
UR  - https://www.frontiersin.org/articles/10.3389/fonc.2026.1881442
AB  - Central vein stenosis (CVS) can complicate peripherally inserted central catheter (PICC) placement by impeding catheter advancement and preventing achievement of an appropriate central tip position. On 23 January 2025, a 57-year-old female with recurrent right breast cancer was admitted for systemic anticancer treatment and required renewed long-term venous access. During a second PICC placement through the left basilic vein, catheter advancement was unexpectedly impeded, and venography confirmed left brachiocephalic vein stenosis with catheter coiling near the stenotic segment. A multidisciplinary team (MDT), including PICC specialist nurses, oncology physicians, cardiovascular surgeons, and ultrasound imaging experts, determined that further advancement across the left stenotic segment posed additional risk. The catheter was therefore withdrawn until the coiling resolved, leaving the tip in the left subclavian vein. After individualized assessment of the patient’s vascular anatomy, treatment requirements, and alternative vascular access options, the catheter was retained at this nonstandard tip position and managed with individualized anticoagulation and clinical surveillance. During approximately six months of follow-up, the patient experienced catheter dislodgement, but no clinically documented catheter-related thrombosis, infection, or drug extravasation occurred. The case highlights that unexpected resistance during PICC advancement may warrant assessment for central venous abnormalities even when peripheral veins appear patent. When CVS is encountered, catheter management should be individualized through MDT assessment, and retention of a PICC in a nonstandard tip position should be regarded as an exceptional strategy.
SN  - 2234-943X
ER  -