Evaluating Reliability and Validity of Heart Rate from the Garmin Instinct 2 During Deadlift Exercises at Different Intensities.
- 1Department of Kinesiology and Nutrition Science, University of Nevada, Las Vegas, Las Vegas, NV 89154, USA.
- 2Department of Kinesiology and Outdoor Recreation, Southern Utah University, Cedar City, UT 84720, USA.
- 3Department of Kinesiology, California State University San Bernardino, San Bernardino, CA 92407, USA.
Abstract
Background and Objectives: Wearable heart rate monitors are widely used for performance monitoring and safety, yet their validity during resistance training is limited. This study evaluated the accuracy and reliability of wrist-worn Garmin Instinct 2 monitors during deadlift exercise across multiple intensities, using the Polar H10 chest strap as the criterion measure. Methods: Twenty-one recreationally active adults (four women, 17 men, 0 identified otherwise) completed deadlift sets at low (RPE 3-4) and moderate-to-high (RPE 6-8) intensities while heart rate (HR) was recorded using four Garmin Instinct 2 devices placed on the inner and outer wrists of each forearm and one Polar H10 chest strap. Inter-device reliability was examined using the Intraclass Correlation Coefficient (ICC [1,2]) and the Coefficient of Variation (CV). Validity was assessed via mean absolute percentage error (MAPE) and Lin's Concordance Correlation Coefficient (CCC). Results: Outer wrist placement met the threshold for reliability and one measure of validity during low intensity exercise (average HR CV = 2.7%, ICC = 0.88, MAPE = 8.5% [left forearm], 9.5% [right forearm], CCC = 0.55 [left forearm], 0.52 [right forearm]; maximal HR CV = 2.9%, ICC = 0.88, MAPE = 3.2% [left forearm], 7.7% [right forearm], CCC = 0.61 [left forearm], 0.60 [right forearm]). No validity thresholds were met during moderate-to-high intensity exercise (average HR MAPE = 15.9% [left forearm], 15.9% [right forearm], CCC = 0.57 [left forearm], 0.60 [right forearm]; maximal HR MAPE = 30.1% [left forearm], 13.5% [right forearm], CCC = 0.53 [left forearm], 0.55 [right forearm]). Inner wrist placement did not meet any reliability or validity threshold for any condition. Conclusions: Outer wrist placement of the Garmin Instinct 2 achieved acceptable MAPE under low-intensity loading, but measures of accuracy appeared to decline with increased intensity. Inner wrist placement failed to return any conditions in which reliability or validity thresholds were met for either average or maximal heart rate. For training or occupational settings requiring precise HR monitoring, chest strap monitors or bicep-worn sensors are still recommended.
Related
- A national survey evaluating the construct validity and reliability of a medical student feedback literacy questionnaire
- Reliability of a functional electromechanical dynamometer for a bilateral standing press exercise at intensities of 30% and 60% of isometric peak force in trained women
- Earlobe Blood Flow Responses to Different Intensities of Inspiratory Resistance Loading in Healthy Young Men
- Effect of Muscle Length on Biceps Femoris Long Head Stiffness During Isometric Knee Flexion at Different Intensities.
- Different Domains and Intensities of Habitual Physical Activity Are Differentially Associated with Cardiovascular Responses to Standardized Exercise.
BibTeX
@article{bovell2026evaluating,
title = {{Evaluating Reliability and Validity of Heart Rate from the Garmin Instinct 2 During Deadlift Exercises at Different Intensities.}},
author = {Jamaal K Bovell and Setareh Zarei and Kynlee Sperry and Jose Vasquez and Jeff Guzman and Catalina Kerwin and Juni Timmins and Nathaniel G Bodell and Marcus M Lawrence and James W Navalta},
journal = {Journal of functional morphology and kinesiology},
year = {2026},
month = nov,
doi = {10.3390/jfmk11040471},
url = {https://europepmc.org/article/MED/43081371},
note = {CC BY},
}
RIS
TY - JOUR
TI - Evaluating Reliability and Validity of Heart Rate from the Garmin Instinct 2 During Deadlift Exercises at Different Intensities.
AU - Jamaal K Bovell
AU - Setareh Zarei
AU - Kynlee Sperry
AU - Jose Vasquez
AU - Jeff Guzman
AU - Catalina Kerwin
AU - Juni Timmins
AU - Nathaniel G Bodell
AU - Marcus M Lawrence
AU - James W Navalta
PY - 2026
DA - 2026/11/10
JO - Journal of functional morphology and kinesiology
DO - 10.3390/jfmk11040471
UR - https://europepmc.org/article/MED/43081371
AB - Background and Objectives: Wearable heart rate monitors are widely used for performance monitoring and safety, yet their validity during resistance training is limited. This study evaluated the accuracy and reliability of wrist-worn Garmin Instinct 2 monitors during deadlift exercise across multiple intensities, using the Polar H10 chest strap as the criterion measure. Methods: Twenty-one recreationally active adults (four women, 17 men, 0 identified otherwise) completed deadlift sets at low (RPE 3-4) and moderate-to-high (RPE 6-8) intensities while heart rate (HR) was recorded using four Garmin Instinct 2 devices placed on the inner and outer wrists of each forearm and one Polar H10 chest strap. Inter-device reliability was examined using the Intraclass Correlation Coefficient (ICC [1,2]) and the Coefficient of Variation (CV). Validity was assessed via mean absolute percentage error (MAPE) and Lin's Concordance Correlation Coefficient (CCC). Results: Outer wrist placement met the threshold for reliability and one measure of validity during low intensity exercise (average HR CV = 2.7%, ICC = 0.88, MAPE = 8.5% [left forearm], 9.5% [right forearm], CCC = 0.55 [left forearm], 0.52 [right forearm]; maximal HR CV = 2.9%, ICC = 0.88, MAPE = 3.2% [left forearm], 7.7% [right forearm], CCC = 0.61 [left forearm], 0.60 [right forearm]). No validity thresholds were met during moderate-to-high intensity exercise (average HR MAPE = 15.9% [left forearm], 15.9% [right forearm], CCC = 0.57 [left forearm], 0.60 [right forearm]; maximal HR MAPE = 30.1% [left forearm], 13.5% [right forearm], CCC = 0.53 [left forearm], 0.55 [right forearm]). Inner wrist placement did not meet any reliability or validity threshold for any condition. Conclusions: Outer wrist placement of the Garmin Instinct 2 achieved acceptable MAPE under low-intensity loading, but measures of accuracy appeared to decline with increased intensity. Inner wrist placement failed to return any conditions in which reliability or validity thresholds were met for either average or maximal heart rate. For training or occupational settings requiring precise HR monitoring, chest strap monitors or bicep-worn sensors are still recommended.
SN - 2411-5142
ER -