Experimental setup for testing nanocalorimeter sensors as a plasma diagnostics tool
Abstract
The application of microfabricated nanocalorimeters for real-time, highly sensitive, and selective monitoring of the energy fluxes from low-pressure plasma discharges has been reported recently. Here, we describe the experimental setup for complementary characterization of nanocalorimeters performance using plasma diagnostics techniques. Langmuir probe, retarding field energy analyzer (RFEA), optical emission spectroscopy (OES), quadrupole mass spectrometry (QMS), and thermocouple-based thermometry constitute the plasma monitor suite. We discuss two application examples of the plasma monitor suite: (1) discrimination between electron- and ion-induced heat fluxes via sensor direct current (DC) biasing, and (2) detection of fast temperature transients in pulsed discharges. The main goal of this work is to demonstrate a nanocalorimetry platform as a real-time metrology for plasma processing and process control.
Related
- Novel 10-dB Directional Coupler for Wireless RF Interrogator of SAW Resonator Sensors: Design, Simulation, and Experimental Investigation
- A Two-Dimensional Physics-Informed Neural Network Model of a Hall Effect Thruster Plasma: Self-Consistent Electrostatics and Physical-Consistency Diagnostics
- Multi-scale assessment of the time-dependent mechanical behavior of perineal tissues via experimental testing and structural analysis
- Towards assessing soft tissue volumetric change from compression testing under MRI : experimental developments and preliminary results
- Experimental and Theoretical Study of Flow Dynamics of Expanding Hydrogen Plasma from an ECR Plasma Source
BibTeX
@misc{corbella2026experimental,
title = {{Experimental setup for testing nanocalorimeter sensors as a plasma diagnostics tool}},
author = {Carles Corbella and Feng Yi and Andrei Kolmakov},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.20328},
eprint = {2609.20328},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.20328},
}
RIS
TY - UNPB
TI - Experimental setup for testing nanocalorimeter sensors as a plasma diagnostics tool
AU - Carles Corbella
AU - Feng Yi
AU - Andrei Kolmakov
PY - 2026
DA - 2026/09/17
PB - arXiv
DO - 10.48550/arxiv.2609.20328
UR - https://arxiv.org/abs/2609.20328
AB - The application of microfabricated nanocalorimeters for real-time, highly sensitive, and selective monitoring of the energy fluxes from low-pressure plasma discharges has been reported recently. Here, we describe the experimental setup for complementary characterization of nanocalorimeters performance using plasma diagnostics techniques. Langmuir probe, retarding field energy analyzer (RFEA), optical emission spectroscopy (OES), quadrupole mass spectrometry (QMS), and thermocouple-based thermometry constitute the plasma monitor suite. We discuss two application examples of the plasma monitor suite: (1) discrimination between electron- and ion-induced heat fluxes via sensor direct current (DC) biasing, and (2) detection of fast temperature transients in pulsed discharges. The main goal of this work is to demonstrate a nanocalorimetry platform as a real-time metrology for plasma processing and process control.
ER -