ECHO-FUSE: a hybrid dual-encoder attention network for patient-level validated left-heart echocardiography segmentation.

  1. 1Department of Computer Science and Engineering, International University of Business Agriculture and Technology (IUBAT), Dhaka, 1230, Bangladesh.
  2. 2Department of Computer Science and Engineering, Jatiya Kabi Kazi Nazrul Islam University (JKKNIU), Mymensingh, 2220, Bangladesh.
  3. 3Department of Data Science, University of North Texas (UNT), Denton, 76203, USA. [email protected].

Abstract

Manual tracing of left-heart borders in echocardiography is still affected by reader variation, and the images themselves often contain speckle, acoustic dropout, shadowing, and uneven contrast. In this work, we evaluate ECHO-FUSE, a dual-encoder attention U-Net for four-class segmentation of apical two-chamber end-diastolic frames from CAMUS. Before inference, each frame is resized in a deterministic way, filtered with an edge-preserving bilateral operation, and contrast-enhanced using CLAHE. The grayscale input is copied into three channels so that ResNet50 and Xception encoders can process the same echocardiographic frame in parallel. Their multi-scale skip features are aligned to matching spatial sizes, fused, and passed through attention-guided decoder blocks to predict background, LV endocardium, LV myocardium, and left atrium. The experimental protocol uses a locked patient-level split of 400 training, 50 validation, and 50 test subjects, with no patient overlap across subsets. The proposed model and four baseline architectures were trained under the same preprocessing, augmentation, checkpointing, and evaluation protocol. On the locked test set, the proposed dual-encoder attention U-Net achieved a patient-level foreground macro-Dice of 0.8607 [95% CI: 0.8355-0.8819], foreground macro IoU of 0.7700 [95% CI: 0.7407-0.7961], and foreground macro HD95 of 10.47 mm [95% CI: 8.02-13.79]. ECHO-FUSE's performance was statistically comparable to the strongest Standard U-Net baseline for Dice (paired Wilcoxon p = 0.8109) and HD95 (p = 0.2571), while significantly outperforming DeepLabV3+ and EfficientNetB0 U-Net. Representative locked-test cases showed accurate ventricular delineation in good and average examples, while the difficult case exposed left atrial segmentation as the main failure mode. These findings support ECHO-FUSE as a reproducible segmentation framework and define clear limits for future multi-view, temporal, and externally validated echocardiographic analysis.

Related

  1. Asymmetric encoder-decoder U-net with hybrid attention and residual dilated convolution for brain tumor segmentation
    Xiaoshuai Cao, Xige Song, Jincan Zhang +2
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0Full textNeurologyFrontiersCrossrefDOAJEurope PMC+1
  2. PECSA Net: Pupil Segmentation Using Attention Integrated Encoder-based Multi-Level Feature Extractor for Analysis of Ocular Dynamics
    Choyichivayalil Arya, Veluswamy Pandiyarasan, Palanisamy Rohini
    Current Directions in Biomedical EngineeringPeer-reviewedCC BY-NC-NDFull textGeneral medicineDOAJ
  3. Hybrid feature pyramid attention and capsule network (FpaNet+CapsNet) for enhanced spatial and contextual feature extraction for improved brain tumor segmentation
    Eman Abdullah Aldakheel, Mohammed Zakariah, Syed Umar Amin +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0NeurologyCrossref
  4. An attention-guided dense convolutional network for automated diabetic foot ulcer segmentation
    Rampriya R. S., Sabari Nathan, Arumuga Arun R.
    Frontiers in EndocrinologyPeer-reviewedCC BY 4.0Full textEndocrinology & metabolismCrossrefEurope PMCPMC
  5. An enhanced U-shape architecture network with cross-scale attention and frequency-domain perception for robust colorectal polyp segmentation
    Rong Gao, Qi Ke, Aiquan Li +2
    PLOS OnePeer-reviewedCC BYFull textNeuroscienceOncologyPLOSEurope PMCPMC
BibTeX
@article{emon2026echofuse,
  title = {{ECHO-FUSE: a hybrid dual-encoder attention network for patient-level validated left-heart echocardiography segmentation.}},
  author = {Ahad Hasan Emon and Nusrat Jahan and Ferdaus Anam Jibon and Md Wadud Mahmud Joy and A H M Kamal and Gahangir Hossain},
  journal = {BMC medical imaging},
  year = {2026},
  month = aug,
  doi = {10.1186/s12880-026-02619-2},
  url = {https://europepmc.org/article/MED/43079307},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - ECHO-FUSE: a hybrid dual-encoder attention network for patient-level validated left-heart echocardiography segmentation.
AU  - Ahad Hasan Emon
AU  - Nusrat Jahan
AU  - Ferdaus Anam Jibon
AU  - Md Wadud Mahmud Joy
AU  - A H M Kamal
AU  - Gahangir Hossain
PY  - 2026
DA  - 2026/08/19
JO  - BMC medical imaging
DO  - 10.1186/s12880-026-02619-2
UR  - https://europepmc.org/article/MED/43079307
AB  - Manual tracing of left-heart borders in echocardiography is still affected by reader variation, and the images themselves often contain speckle, acoustic dropout, shadowing, and uneven contrast. In this work, we evaluate ECHO-FUSE, a dual-encoder attention U-Net for four-class segmentation of apical two-chamber end-diastolic frames from CAMUS. Before inference, each frame is resized in a deterministic way, filtered with an edge-preserving bilateral operation, and contrast-enhanced using CLAHE. The grayscale input is copied into three channels so that ResNet50 and Xception encoders can process the same echocardiographic frame in parallel. Their multi-scale skip features are aligned to matching spatial sizes, fused, and passed through attention-guided decoder blocks to predict background, LV endocardium, LV myocardium, and left atrium. The experimental protocol uses a locked patient-level split of 400 training, 50 validation, and 50 test subjects, with no patient overlap across subsets. The proposed model and four baseline architectures were trained under the same preprocessing, augmentation, checkpointing, and evaluation protocol. On the locked test set, the proposed dual-encoder attention U-Net achieved a patient-level foreground macro-Dice of 0.8607 [95% CI: 0.8355-0.8819], foreground macro IoU of 0.7700 [95% CI: 0.7407-0.7961], and foreground macro HD95 of 10.47 mm [95% CI: 8.02-13.79]. ECHO-FUSE's performance was statistically comparable to the strongest Standard U-Net baseline for Dice (paired Wilcoxon p = 0.8109) and HD95 (p = 0.2571), while significantly outperforming DeepLabV3+ and EfficientNetB0 U-Net. Representative locked-test cases showed accurate ventricular delineation in good and average examples, while the difficult case exposed left atrial segmentation as the main failure mode. These findings support ECHO-FUSE as a reproducible segmentation framework and define clear limits for future multi-view, temporal, and externally validated echocardiographic analysis.
SN  - 1471-2342
ER  -