Comparing Postoperative Complications Following Internal Fixation of Distal Fibular Fractures With Either One-Third Tubular or Anatomical Distal Fibular Plates.
4 affiliations
- 1Department of Orthopedic Surgery, Regional Hospital Randers, Randers, DNK.
- 2Department of Clinical Medicine, MidtSim, Central Denmark Region, Aarhus University, Aarhus, DNK.
- 3Department of Clinical Medicine, Faculty of Health, Aarhus University, Aarhus, DNK.
- 4Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus, DNK.
Abstract
Background Ankle fractures are common and frequently treated with internal fixation using either one-third tubular plates or anatomical distal fibular plates. This study investigated whether postoperative complication rates differ between plate types. Methodology This retrospective cohort study included patients who underwent surgical treatment of distal fibular fractures at a regional hospital in Denmark between February 2020 and January 2024. Patients were treated with either a one-third tubular plate or an anatomical distal fibular plate. Postoperative complications, reoperations, fracture classification, surgeon experience, and baseline characteristics were recorded. Complication rates were compared using proportions with 95% confidence intervals (CIs) and chi-square tests. Patients with open fractures, multi-trauma, primary external fixation, other osteosynthesis methods, residence outside the hospital region, or death within 12 months were excluded. Results Among 268 included patients, 114 (42.5%) experienced one or more postoperative complications. No statistically significant difference in complication rates was observed for one-third tubular plates (101/238, 42.4%; 95% CI 36.1-48.7) and anatomical distal fibular plates (13/30, 43.3%; 95% CI 25.6-61.0; P = 0.93). Rates increased from 41/120 (34.2%; 95% CI 26.3-43.0) with lateral plating without additional medial or anteroposterior (AP) fixation to 59/125 (47.2%; 95% CI 38.8-55.8) with additional medial screws and 14/23 (60.9%; 95% CI 40.8-77.8) with additional AP screws (P = 0.02). Fracture classification, baseline characteristics, and surgeon experience were not consistently associated with complication risk. Conclusions No statistically significant difference in postoperative complication rates was observed between one-third tubular and anatomical distal fibular plates. However, the small anatomical plate group and potential confounding limit the interpretation of this finding. Additional medial or AP fixation was associated with higher complication rates, potentially reflecting greater fracture complexity. Larger studies with adjusted analyses are needed to further investigate these associations.
Related
- Reported outcomes for patients following postoperative periprosthetic femoral fractures : a systematic review
- Commentary on “Postoperative complications and mechanical outcomes following endoscopic versus open lumbar fusion: a propensity-matched analysis”
- Postoperative complications and care requirements following Achilles tendon repair : A retrospective cohort study
- Postoperative Complications After the Surgical Management of Panfacial Fractures: A Retrospective Cohort Study
- Association of bone mineral-reducing medications with two-year complications following open reduction and internal fixation of ankle fractures: a propensity score-matched analysis
BibTeX
@article{calmar2026comparing,
title = {{Comparing Postoperative Complications Following Internal Fixation of Distal Fibular Fractures With Either One-Third Tubular or Anatomical Distal Fibular Plates.}},
author = {Helene F Calmar and Rasmus P Severinsen and Jacob S Engbjerg and Daniel Wæver},
journal = {Cureus},
year = {2026},
month = nov,
doi = {10.7759/cureus.120107},
url = {https://europepmc.org/article/MED/43075051},
note = {CC BY},
}
RIS
TY - JOUR
TI - Comparing Postoperative Complications Following Internal Fixation of Distal Fibular Fractures With Either One-Third Tubular or Anatomical Distal Fibular Plates.
AU - Helene F Calmar
AU - Rasmus P Severinsen
AU - Jacob S Engbjerg
AU - Daniel Wæver
PY - 2026
DA - 2026/11/22
JO - Cureus
DO - 10.7759/cureus.120107
UR - https://europepmc.org/article/MED/43075051
AB - Background Ankle fractures are common and frequently treated with internal fixation using either one-third tubular plates or anatomical distal fibular plates. This study investigated whether postoperative complication rates differ between plate types. Methodology This retrospective cohort study included patients who underwent surgical treatment of distal fibular fractures at a regional hospital in Denmark between February 2020 and January 2024. Patients were treated with either a one-third tubular plate or an anatomical distal fibular plate. Postoperative complications, reoperations, fracture classification, surgeon experience, and baseline characteristics were recorded. Complication rates were compared using proportions with 95% confidence intervals (CIs) and chi-square tests. Patients with open fractures, multi-trauma, primary external fixation, other osteosynthesis methods, residence outside the hospital region, or death within 12 months were excluded. Results Among 268 included patients, 114 (42.5%) experienced one or more postoperative complications. No statistically significant difference in complication rates was observed for one-third tubular plates (101/238, 42.4%; 95% CI 36.1-48.7) and anatomical distal fibular plates (13/30, 43.3%; 95% CI 25.6-61.0; P = 0.93). Rates increased from 41/120 (34.2%; 95% CI 26.3-43.0) with lateral plating without additional medial or anteroposterior (AP) fixation to 59/125 (47.2%; 95% CI 38.8-55.8) with additional medial screws and 14/23 (60.9%; 95% CI 40.8-77.8) with additional AP screws (P = 0.02). Fracture classification, baseline characteristics, and surgeon experience were not consistently associated with complication risk. Conclusions No statistically significant difference in postoperative complication rates was observed between one-third tubular and anatomical distal fibular plates. However, the small anatomical plate group and potential confounding limit the interpretation of this finding. Additional medial or AP fixation was associated with higher complication rates, potentially reflecting greater fracture complexity. Larger studies with adjusted analyses are needed to further investigate these associations.
SN - 2168-8184
ER -