Pendellösung length-scale neutron and X-ray interferometry
Abstract
Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 μm and 350 μm, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.
Related
- Decoupling Strain-Rate Sensitivity and Deformation Length Scale Effects in Neutron-Irradiated Tungsten: A Coupled Nano-Indentation, HR-EBSD and Crystal Plasticity Study
- New Method for Path-length Equalization of Long Single-mode Fibers for Interferometry
- Josephson interferometry in an Oppenheimer--Snyder-like scale-dependent black-hole spacetime
- Length-scale dependence of collective time reparameterization in swap dynamics
- Emergent Active-Blob Length Scale Governs the Collapse Transition of Tangentially Driven Polymers
BibTeX
@misc{lailey2026pendellösung,
title = {{Pendellösung length-scale neutron and X-ray interferometry}},
author = {Owen Lailey and Alexandre Boutot and David G. Cory and Joseph P. Cotter and Vishal Dhamgaye and Tao Hong and Michael G. Huber and Young-June Kim and Winfried Kockelmann and Jeremy W. Paster and Dusan Sarenac and Kawal Sawhney and Naume Shentevski and Ivar Taminiau and Dmitry A. Pushin},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2609.24709},
eprint = {2609.24709},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2609.24709},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Pendellösung length-scale neutron and X-ray interferometry
AU - Owen Lailey
AU - Alexandre Boutot
AU - David G. Cory
AU - Joseph P. Cotter
AU - Vishal Dhamgaye
AU - Tao Hong
AU - Michael G. Huber
AU - Young-June Kim
AU - Winfried Kockelmann
AU - Jeremy W. Paster
AU - Dusan Sarenac
AU - Kawal Sawhney
AU - Naume Shentevski
AU - Ivar Taminiau
AU - Dmitry A. Pushin
PY - 2026
DA - 2026/09/21
PB - arXiv
DO - 10.48550/arxiv.2609.24709
UR - https://arxiv.org/abs/2609.24709
AB - Neutron and X-ray perfect-crystal interferometers (PCIs) are powerful platforms for studies of fundamental physics and phase-contrast imaging. Further enhancing several PCI capabilities requires reducing crystal blade thickness to the micron scale, which minimizes dynamical-diffraction image blur, permits operation in the pendellösung regime where blade thickness controls beam splitting, and reduces absorption for simultaneous neutron and X-ray operation. However, fabricating multiple crystal blades with identical micrometer-scale thicknesses over centimeter-scale areas remains a major challenge. Here, using a non-etching sub-micron fabrication technique, we demonstrate silicon triple-Laue interferometers with equal-blade-thicknesses of 110 μm and 350 μm, operated with both neutrons and X-rays. These devices are the thinnest PCIs realized to date, enabling a factor-of-six reduction in dynamical-diffraction beam spreading for improved phase-contrast imaging, while reaching the single pendellösung length regime in which crystal thickness provides an experimentally accessible control parameter for engineered quantum-optical beam splitting of plane-wave inputs. These results motivate multi-blade PCI designs utilizing identical half-pendellösung crystal lamellae that are proposed for neutron spin--orbit and electric dipole moment measurements.
ER -