Spending Scarce Confirmatory PET Measurements: Target-Aligned Validation in A4/LEARN
Abstract
Anti-amyloid therapies and blood-based biomarkers are changing Alzheimer disease workups into a two-stage measurement workflow: screen broadly with cheaper information, then spend scarce confirmatory amyloid measurements where they support the decision that will be reported. Amyloid positron-emission tomography (PET) remains one such protocol measurement for amyloid burden, but PET slots, trial budgets, and payer-facing evidence packages are finite. This paper asks a deliberately operational question: when is simple transparent PET validation enough, and when is a fitted residual-uncertainty score worth the added complexity? For a weighted protocol target, the first-order value of validating subject i is the product of target influence and residual protocol uncertainty. Generic uncertainty sampling uses only the second factor and can spend PET measurements on subjects that are hard to predict but weak for the scientific, clinical, or commercial claim. We apply this rule to the A4/LEARN PET archive, treating observed PET as a design laboratory for scarce-confirmation studies. For the primary APOE4 carrier versus non-carrier contrast in Centiloid 24-or-higher PET positivity, simple APOE4-balanced validation recovers nearly all of the target-specific gain: at PET budget 200, the confidence-interval width ratio relative to random validation is 0.923 for APOE4 balancing and 0.914 for target-specific scoring, while generic uncertainty sampling is 0.980. Other targets behave differently: target-specific scoring gives larger gains for an age-slope analysis and for cutoff-indexed PET positivity. The practical message is simple: spend scarce protocol measurements according to the claim being validated, not only according to prediction uncertainty.
Related
- Data-Matrix-Based Overall Goodness-of-Fit Testing for Confirmatory Factor Analysis: In-Sample Prediction Error for Observed Variables
- Rapid drone-based wildfire detection at a fraction of current prevention spending
- Gain-function optimisation of graphical multiple testing procedures for confirmatory clinical trials
- Robust Alpha Spending for Unstable Data.
- Bayesian hypergraph inference from scarce and noisy dynamical observations
BibTeX
@misc{cui2026spending,
title = {{Spending Scarce Confirmatory PET Measurements: Target-Aligned Validation in A4/LEARN}},
author = {Eliuvish Han Cui and Qiang Yang and Meredith Mengmeng Zhang},
howpublished = {arXiv},
year = {2026},
month = sep,
doi = {10.48550/arxiv.2608.22223},
eprint = {2608.22223},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2608.22223},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Spending Scarce Confirmatory PET Measurements: Target-Aligned Validation in A4/LEARN
AU - Eliuvish Han Cui
AU - Qiang Yang
AU - Meredith Mengmeng Zhang
PY - 2026
DA - 2026/09/17
PB - arXiv
DO - 10.48550/arxiv.2608.22223
UR - https://arxiv.org/abs/2608.22223
AB - Anti-amyloid therapies and blood-based biomarkers are changing Alzheimer disease workups into a two-stage measurement workflow: screen broadly with cheaper information, then spend scarce confirmatory amyloid measurements where they support the decision that will be reported. Amyloid positron-emission tomography (PET) remains one such protocol measurement for amyloid burden, but PET slots, trial budgets, and payer-facing evidence packages are finite. This paper asks a deliberately operational question: when is simple transparent PET validation enough, and when is a fitted residual-uncertainty score worth the added complexity? For a weighted protocol target, the first-order value of validating subject i is the product of target influence and residual protocol uncertainty. Generic uncertainty sampling uses only the second factor and can spend PET measurements on subjects that are hard to predict but weak for the scientific, clinical, or commercial claim. We apply this rule to the A4/LEARN PET archive, treating observed PET as a design laboratory for scarce-confirmation studies. For the primary APOE4 carrier versus non-carrier contrast in Centiloid 24-or-higher PET positivity, simple APOE4-balanced validation recovers nearly all of the target-specific gain: at PET budget 200, the confidence-interval width ratio relative to random validation is 0.923 for APOE4 balancing and 0.914 for target-specific scoring, while generic uncertainty sampling is 0.980. Other targets behave differently: target-specific scoring gives larger gains for an age-slope analysis and for cutoff-indexed PET positivity. The practical message is simple: spend scarce protocol measurements according to the claim being validated, not only according to prediction uncertainty.