Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BY 4.0Journal of Cosmetic Dermatology

755‐nm Picosecond Laser Versus Intense Pulsed Light for Diffuse Lip Hyperpigmentation: A Prospective, Randomized, Controlled, Evaluator‐Blinded Trial

6 affiliations
  1. 1China‐Japan Friendship Hospital (Institute of Clinical Medical Sciences) Chinese Academy of Medical Sciences & Peking Union Medical College Beijing China
  2. 2Department of Dermatology Peking University First Hospital Beijing China
  3. 3Department of Dermatology China‐Japan Friendship Hospital Beijing China
  4. 4China‐Japan Friendship Institute of Clinical Medical Sciences Beijing China
  5. 5Big Data Center, Department of Information China‐Japan Friendship Hospital Beijing China
  6. 6NHC Key Laboratory of Clinical Big Data Standardization & Integration Beijing China

Abstract

Background: Lip hyperpigmentation is an aesthetic concern. Evidence supporting light‐based treatments for diffuse lip hyperpigmentation is limited. This study evaluated the efficacy and safety of 755‐nm picosecond laser versus intense pulsed light (IPL) for the treatment of diffuse lip hyperpigmentation.

Methods: In this 12‐week, prospective, randomized, controlled, evaluator‐blinded trial, 50 patients were assigned 1:1 to five sessions of either a 755‐nm picosecond laser or IPL at 2‐week intervals. The primary endpoint was the Physician's Global Assessment (PGA) score at Week 12. Secondary endpoints included objective colorimetric parameters (CIE L*, a*, b*), Global Aesthetic Improvement Scale (GAIS), Dermatology Life Quality Index (DLQI), and pain Numerical Rating Scale (NRS). Treatment‐related adverse events were also recorded.

Results: Forty‐four patients completed the study (IPL, n = 20; picosecond laser, n = 24). Among completers, the median PGA score at Week 12 was higher in the picosecond laser group than in the IPL group (2.5 [IQR, 2–3] vs. 1.5 [IQR, 1–2.375]; p = 0.007; Hodges–Lehmann estimate, 0.5 PGA points; 95% CI, 0–1.0), and more patients achieved at least moderate improvement (79.2% vs. 45.0%). In sensitivity analyses, statistical significance depended on assumptions about missing PGA outcomes. Objective colorimetric changes did not differ significantly between groups (all p > 0.05). All completers reported improvement on the GAIS, and DLQI scores decreased in both groups. Pain NRS scores were higher in the picosecond laser group (p < 0.01). Transient scaling occurred in 2 ps‐laser recipients; no adverse events were reported with IPL.

Conclusion: Both the 755‐nm picosecond laser and IPL showed improvement in diffuse lip hyperpigmentation, with favorable safety profiles. The picosecond laser showed greater physician‐assessed improvement among completers, whereas IPL was better tolerated. These findings may help guide individualized treatment selection.

Trial Registration: Chinese Clinical Trial Registry, ChiCTR2600116083

Related

  1. Study Protocol for a Participant- and Evaluator-Blinded, Randomized Controlled Trial of the Effect and Feasibility of REHA-Glasses for Gait Rehabilitation in Individuals With Acute Stroke Lateropulsion.
    Chiaki Yokota, Shin Ito, Yuka Sano +4
    Circulation reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMCPMC
  2. Treatment of Acne-Induced Facial Post-Inflammatory Hyperpigmentation With a New 2-MNG-Containing Routine Versus a Thiamidol-Containing Routine-A Monocentric Prospective Double-Blind Randomized Comparative Trial.
    Thierry Passeron, Guénaëlle Le Dantec, Samir Salah +5
    Journal of cosmetic dermatologyPeer-reviewedCC BYFull text2 citedGeneral medicineEurope PMC
  3. Fractional Picosecond Laser Treatment of Facial Superficial Scars Associated with Hyperpigmentation in Chinese Patients
    Zhihao Xu, Yue Zhai, Yuting Men +2
    Clinical, Cosmetic and Investigational DermatologyPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  4. Efficacy and Safety of L-Carnosine-Containing Hyaluronate Injection for Facial Skin Hydration and Brightness: A Randomized, Controlled, Evaluator-Blinded Trial.
    Zhanhong Li, Jingfang Sun, Zhehu Jin +22
    Journal of cosmetic dermatologyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Longitudinal Imaging Patterns Following an Imaging-Guided Dual-Axis Picosecond Nd:YAG Protocol for Facial Hyperpigmentation.
    Sung Joo Kwon, Ji Yu Bang
    Journal of cosmetic dermatologyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{ouyang2026755nm,
  title = {{755‐nm Picosecond Laser Versus Intense Pulsed Light for Diffuse Lip Hyperpigmentation: A Prospective, Randomized, Controlled, Evaluator‐Blinded Trial}},
  author = {Hongfei Ouyang and Jiahui Han and Lili Chen and Xuejiao Song and Yong Cui and Ruixing Yu},
  journal = {Journal of Cosmetic Dermatology},
  year = {2026},
  month = nov,
  doi = {10.1111/jocd.71295},
  url = {https://doi.org/10.1111/jocd.71295},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - 755‐nm Picosecond Laser Versus Intense Pulsed Light for Diffuse Lip Hyperpigmentation: A Prospective, Randomized, Controlled, Evaluator‐Blinded Trial
AU  - Hongfei Ouyang
AU  - Jiahui Han
AU  - Lili Chen
AU  - Xuejiao Song
AU  - Yong Cui
AU  - Ruixing Yu
PY  - 2026
DA  - 2026/11/13
JO  - Journal of Cosmetic Dermatology
DO  - 10.1111/jocd.71295
UR  - https://doi.org/10.1111/jocd.71295
AB  - Background: Lip hyperpigmentation is an aesthetic concern. Evidence supporting light‐based treatments for diffuse lip hyperpigmentation is limited. This study evaluated the efficacy and safety of 755‐nm picosecond laser versus intense pulsed light (IPL) for the treatment of diffuse lip hyperpigmentation.  Methods: In this 12‐week, prospective, randomized, controlled, evaluator‐blinded trial, 50 patients were assigned 1:1 to five sessions of either a 755‐nm picosecond laser or IPL at 2‐week intervals. The primary endpoint was the Physician's Global Assessment (PGA) score at Week 12. Secondary endpoints included objective colorimetric parameters (CIE L*, a*, b*), Global Aesthetic Improvement Scale (GAIS), Dermatology Life Quality Index (DLQI), and pain Numerical Rating Scale (NRS). Treatment‐related adverse events were also recorded.  Results: Forty‐four patients completed the study (IPL, n = 20; picosecond laser, n = 24). Among completers, the median PGA score at Week 12 was higher in the picosecond laser group than in the IPL group (2.5 [IQR, 2–3] vs. 1.5 [IQR, 1–2.375]; p = 0.007; Hodges–Lehmann estimate, 0.5 PGA points; 95% CI, 0–1.0), and more patients achieved at least moderate improvement (79.2% vs. 45.0%). In sensitivity analyses, statistical significance depended on assumptions about missing PGA outcomes. Objective colorimetric changes did not differ significantly between groups (all p > 0.05). All completers reported improvement on the GAIS, and DLQI scores decreased in both groups. Pain NRS scores were higher in the picosecond laser group (p < 0.01). Transient scaling occurred in 2 ps‐laser recipients; no adverse events were reported with IPL.  Conclusion: Both the 755‐nm picosecond laser and IPL showed improvement in diffuse lip hyperpigmentation, with favorable safety profiles. The picosecond laser showed greater physician‐assessed improvement among completers, whereas IPL was better tolerated. These findings may help guide individualized treatment selection.  Trial Registration: Chinese Clinical Trial Registry, ChiCTR2600116083
SN  - 1473-2130
SN  - 1473-2165
ER  -