Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 2 min ago
PreprintarXiv licencearXiv

Machine Learning-Based Inter-Crystal Scatter Recovery for Ultra-High Resolution PET Imaging

Abstract

Inter-crystal scatter (ICS) events pose a significant challenge in ultrahigh- resolution positron emission tomography (UHR-PET), especially as detector crystals become smaller and their readouts increasingly segmented. Current approaches either reject these events, reducing sensitivity, or accept them with suboptimal positioning algorithms, degrading image resolution. We present a feed forward neural network to optimize ICS event recovery by inferring the line-of-response belonging to the first Compton interaction. Our approach was validated using both Monte Carlo simulations and experimental data from the fully pixelated LabPET-IIbased preclinical and brain UHR-PET scanners.Results demonstrate a 70% to 106% increase in sensitivity while preserving sub-millimeter spatial resolvability (down to 1.6 mm) compared to conventional methods. This ICS recovery approach is an effective solution that compensates for the lower detection efficiency of small, pixelated detectors in UHR-PET, enabling reduced scan times and lower radiation doses while largely preserving image quality.

Related

  1. Symmetry-aware super-resolution of crystal orientation maps via invariant latent-space learning
    Umang Garg, Warren Zamudio, McLean P. Echlin +3
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  2. Benchmarking Universal Machine Learning Force Fields for Crystal Structure Prediction of High-Energy Molecular Systems
    Musiha Mahfuza Mukta, Osman Goni Ridwan, Romain Perriot +1
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  3. RAFT-DVC: Resolution-Aware Machine Learning-Based Digital Volume Correlation
    Zixiang Tong, Lehu Bu, Jin Yang
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  4. Machine learning for sample-based quantum diagonalization: a review of generative configuration recovery and the classical-simulability frontier
    Nicolás Bonilla Vargas
    arXivPreprintCC BY 4.0Full textPhysical chemistryQuantum physics & quantum informationarXiv
  5. Symmetry- and Property-Aware Crystal Generation with Reinforcement Learning for Inverse Materials Design
    Ting-Wei Hsu, Arun Bansil, Qimin Yan
    arXivPreprintCC BY 4.0Full textComputational physicsCondensed matterarXiv
BibTeX
@misc{bernier2026machine,
  title = {{Machine Learning-Based Inter-Crystal Scatter Recovery for Ultra-High Resolution PET Imaging}},
  author = {Alexandre Bernier and Roger Lecomte and Jean-Baptiste Michaud},
  howpublished = {arXiv},
  year = {2026},
  month = aug,
  doi = {10.48550/arxiv.2608.07155},
  eprint = {2608.07155},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.07155},
}
RIS
TY  - UNPB
TI  - Machine Learning-Based Inter-Crystal Scatter Recovery for Ultra-High Resolution PET Imaging
AU  - Alexandre Bernier
AU  - Roger Lecomte
AU  - Jean-Baptiste Michaud
PY  - 2026
DA  - 2026/08/07
PB  - arXiv
DO  - 10.48550/arxiv.2608.07155
UR  - https://arxiv.org/abs/2608.07155
AB  - Inter-crystal scatter (ICS) events pose a significant challenge in ultrahigh- resolution positron emission tomography (UHR-PET), especially as detector crystals become smaller and their readouts increasingly segmented. Current approaches either reject these events, reducing sensitivity, or accept them with suboptimal positioning algorithms, degrading image resolution. We present a feed forward neural network to optimize ICS event recovery by inferring the line-of-response belonging to the first Compton interaction. Our approach was validated using both Monte Carlo simulations and experimental data from the fully pixelated LabPET-IIbased preclinical and brain UHR-PET scanners.Results demonstrate a 70% to 106% increase in sensitivity while preserving sub-millimeter spatial resolvability (down to 1.6 mm) compared to conventional methods. This ICS recovery approach is an effective solution that compensates for the lower detection efficiency of small, pixelated detectors in UHR-PET, enabling reduced scan times and lower radiation doses while largely preserving image quality.
ER  -