Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 30 min ago
PreprintarXiv licencearXiv

Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons

Abstract

Measurements with undetected photons infer properties of a probe beam that is never detected, transferring mid-infrared information onto silicon-friendly wavelengths. Tomography in this paradigm has so far relied on switched settings or scanned phases, referenced across a drift-sensitive campaign; no protocol reads all Jones parameters from one frame. We show that a folded nonlinear interferometer with a diagonally pumped crossed-crystal source performs coherent process tomography of the undetected beam in a single spectrometer frame: it reconstructs all seven parameters of the beam's round-trip Jones matrix, the coherent part of the channel. Birefringent group-delay walk-off, normally a calibration nuisance, acts as a frequency multiplexer: each Jones-matrix element is assigned its own carrier, a spectral fringe period paired with a detector port. Because the multiplexing exploits the down-conversion bandwidth rather than merely tolerating it, a single Fourier transform per detector trace returns all four moduli and all three relative phases across that bandwidth, i.e., the full round-trip Jones spectrum up to a global phase, with no scan or setting change (after a one-time reference frame). Simultaneity makes every relative phase immune to common-mode drift, and a dark carrier, a self-interference term that unitarity forces to vanish, provides a built-in null test. For realistic parameters of a periodically poled KTP source the scheme yields wavelength-resolved mid-infrared polarimetry across 3.5-4.2 microns (~80 spectral points per Jones element) on a silicon camera, extending to depth-resolved Jones matrices, i.e., polarization-sensitive optical coherence tomography with undetected photons. A Fisher-information analysis, the first we are aware of in undetected-photon tomography, sets the precision budget and compares delay multiplexing to sequential protocols at equal photon number.

Related

  1. Quantum undetected optical projection tomography
    Nathan Gemmell, Emma Pearce, Jefferson Florez +3
    Optics ExpressPeer-reviewedLicence not statedAtomic, molecular & optical physicsCrossref
  2. High Resolution Hyperspectral Quantum Infrared Imaging with Undetected Photons
    Aadi Suketu Bharatia, Vidya Prakash Muppalla, Ananya Asthana +4
    arXivPreprintarXiv licenceFull textOptics & photonicsQuantum physics & quantum informationarXiv
  3. Undetected Photon Spectroscopy in the Long-wave and Far Infrared
    Jinghan Dong, Jingrui Zhang, Haichen Zhou +3
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationOptics & photonicsarXiv
  4. A unified sensitivity kernel for coherent wave tomography in radar, seismic, ultrasound, and optical imaging
    Alexey Yamilov
    arXivPreprintCC BY-NC-ND 4.0Full textOptics & photonicsarXiv
  5. Scalable Tomography of Coherent Noise via Stabilizer-Code Polarization
    Long Huang
    arXivPreprintarXiv licenceFull textQuantum physics & quantum informationarXiv
BibTeX
@misc{zeja2026singleshot,
  title = {{Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons}},
  author = {Marthe Zeja and Wen-Zhe Yan and Zhibo Hou and Sven Ramelow},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.31043},
  eprint = {2609.31043},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.31043},
}
RIS
TY  - UNPB
TI  - Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons
AU  - Marthe Zeja
AU  - Wen-Zhe Yan
AU  - Zhibo Hou
AU  - Sven Ramelow
PY  - 2026
DA  - 2026/09/25
PB  - arXiv
DO  - 10.48550/arxiv.2609.31043
UR  - https://arxiv.org/abs/2609.31043
AB  - Measurements with undetected photons infer properties of a probe beam that is never detected, transferring mid-infrared information onto silicon-friendly wavelengths. Tomography in this paradigm has so far relied on switched settings or scanned phases, referenced across a drift-sensitive campaign; no protocol reads all Jones parameters from one frame. We show that a folded nonlinear interferometer with a diagonally pumped crossed-crystal source performs coherent process tomography of the undetected beam in a single spectrometer frame: it reconstructs all seven parameters of the beam's round-trip Jones matrix, the coherent part of the channel. Birefringent group-delay walk-off, normally a calibration nuisance, acts as a frequency multiplexer: each Jones-matrix element is assigned its own carrier, a spectral fringe period paired with a detector port. Because the multiplexing exploits the down-conversion bandwidth rather than merely tolerating it, a single Fourier transform per detector trace returns all four moduli and all three relative phases across that bandwidth, i.e., the full round-trip Jones spectrum up to a global phase, with no scan or setting change (after a one-time reference frame). Simultaneity makes every relative phase immune to common-mode drift, and a dark carrier, a self-interference term that unitarity forces to vanish, provides a built-in null test. For realistic parameters of a periodically poled KTP source the scheme yields wavelength-resolved mid-infrared polarimetry across 3.5-4.2 microns (~80 spectral points per Jones element) on a silicon camera, extending to depth-resolved Jones matrices, i.e., polarization-sensitive optical coherence tomography with undetected photons. A Fisher-information analysis, the first we are aware of in undetected-photon tomography, sets the precision budget and compares delay multiplexing to sequential protocols at equal photon number.
ER  -