Dual-purpose Laparoscopy and Bipedicled Anterolateral Thigh Flap for Abdominal Wall Reconstruction After High-voltage Electrical Burn
- 1From the * Division of Plastic and Reconstructive Surgery, Department of General Surgery, Nakornping Hospital, Chiang Mai, Thailand
- 2† Division of Minimally Invasive Surgery, Department of General Surgery, Nakornping Hospital, Chiang Mai, Thailand.
Abstract
High-voltage electrical burns involving the abdominal wall pose complex management challenges, including delayed bowel perforation, progressive tissue necrosis, and durable reconstruction in compromised tissue. To our knowledge, no standardized approach has been described that combines visceral surveillance with abdominal wall reconstruction in this setting. We report a case of a 43-year-old man who sustained a 22,000-volt electrical injury with 30% total body surface area burns and a full-thickness lower abdominal wall defect (16 × 13 cm) exposing the intact peritoneum. Triple-contrast computed tomography on day 3 excluded bowel perforation. On day 22, diagnostic laparoscopy was performed for delayed visceral surveillance; in the absence of bowel pathology, intraperitoneal onlay mesh reinforcement was performed during the same procedure. On day 27, a bipedicled anterolateral thigh fasciocutaneous flap was elevated; sequential 10-minute bulldog clamp testing of each perforator produced equivalent reductions in perfusion, prompting a 4-day delay for choke-vessel maturation. On day 31, the flap was re-elevated and transposed, with the fascia lata sutured to the anterior rectus sheath as a second reinforcement layer superficial to the intraperitoneal onlay mesh. At the 6-month follow-up, the patient demonstrated complete wound healing, stable abdominal wall integrity without clinical hernia on physical examination or with Valsalva maneuver, independent ambulation with a below-knee prosthesis, and return to modified work duties. This integrated single-stage laparoscopic approach combining delayed visceral surveillance with definitive abdominal wall reinforcement may inform management of similar injuries.
Related
- High-Voltage Electrical Injury Causing a Full-Thickness Laryngotracheal Wall Defect: Reconstruction With an Anterolateral Thigh Free Flap and an Inverted Split-Thickness Skin Graft
- Reverse Anterolateral Thigh Flap for Lower Extremity Reconstruction: A Scoping Review
- Predictors of Salvage After Re‐Exploration of Compromised Free Anterolateral Thigh Flaps for Post‐Traumatic Extremity Reconstruction
- Independent Anatomic Double‐Bundle Anterolateral Ligament Reconstruction Using a Pedicled Gracilis Graft During Anterior Cruciate Ligament Reconstruction
- Staged Orthoplastic Soft-Tissue Reconstruction of Complex Tibial Fracture-Related Infection Using a Chimeric Anterolateral Thigh Free Flap After Failed Soleus Muscle Flap: A Case Report
BibTeX
@article{pattanaongkasuwan2026dualpurpose,
title = {{Dual-purpose Laparoscopy and Bipedicled Anterolateral Thigh Flap for Abdominal Wall Reconstruction After High-voltage Electrical Burn}},
author = {Pattana Ongkasuwan, MD and Chotirot Angkurawaranon, MD},
journal = {Plastic and Reconstructive Surgery, Global Open},
year = {2026},
month = oct,
doi = {10.1097/gox.0000000000008145},
url = {https://doi.org/10.1097/gox.0000000000008145},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Dual-purpose Laparoscopy and Bipedicled Anterolateral Thigh Flap for Abdominal Wall Reconstruction After High-voltage Electrical Burn
AU - Pattana Ongkasuwan, MD
AU - Chotirot Angkurawaranon, MD
PY - 2026
DA - 2026/10/29
JO - Plastic and Reconstructive Surgery, Global Open
DO - 10.1097/gox.0000000000008145
UR - https://doi.org/10.1097/gox.0000000000008145
AB - High-voltage electrical burns involving the abdominal wall pose complex management challenges, including delayed bowel perforation, progressive tissue necrosis, and durable reconstruction in compromised tissue. To our knowledge, no standardized approach has been described that combines visceral surveillance with abdominal wall reconstruction in this setting. We report a case of a 43-year-old man who sustained a 22,000-volt electrical injury with 30% total body surface area burns and a full-thickness lower abdominal wall defect (16 × 13 cm) exposing the intact peritoneum. Triple-contrast computed tomography on day 3 excluded bowel perforation. On day 22, diagnostic laparoscopy was performed for delayed visceral surveillance; in the absence of bowel pathology, intraperitoneal onlay mesh reinforcement was performed during the same procedure. On day 27, a bipedicled anterolateral thigh fasciocutaneous flap was elevated; sequential 10-minute bulldog clamp testing of each perforator produced equivalent reductions in perfusion, prompting a 4-day delay for choke-vessel maturation. On day 31, the flap was re-elevated and transposed, with the fascia lata sutured to the anterior rectus sheath as a second reinforcement layer superficial to the intraperitoneal onlay mesh. At the 6-month follow-up, the patient demonstrated complete wound healing, stable abdominal wall integrity without clinical hernia on physical examination or with Valsalva maneuver, independent ambulation with a below-knee prosthesis, and return to modified work duties. This integrated single-stage laparoscopic approach combining delayed visceral surveillance with definitive abdominal wall reinforcement may inform management of similar injuries.
SN - 2169-7574
ER -