Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 50 min ago
Peer-reviewedCC BY 4.0Frontiers in Genetics

Study on copy number variant detection results of 472 fetuses with non-structural ultrasound abnormalities in non-advanced age pregnant women and the correlation with adverse obstetric history

4 affiliations
  1. 1Department of Prenatal Diagnostic Center, Meizhou People’s Hospital, Meizhou Academy of Medical Sciences, Meizhou, China
  2. 2Meizhou Municipal Engineering and Technology Research Center for Molecular Diagnostics of Major Genetic Disorders, Meizhou People’s Hospital, Meizhou Academy of Medical Sciences, Meizhou, China
  3. 3Department of Ultrasound, Meizhou People’s Hospital, Meizhou Academy of Medical Sciences, Meizhou, China
  4. 4Department of Obstetrics, Meizhou People’s Hospital, Meizhou Academy of Medical Sciences, Meizhou, China

Abstract

Objective: To investigate copy number variant (CNV) results in 472 fetuses with non-structural ultrasound abnormalities among pregnant women under 35 years, and analyze the association between adverse obstetric history and pathogenic/likely pathogenic (P/LP) CNVs and variants of uncertain significance (VUS).

Methods: A total of 472 pregnant women aged <35 years with fetal non-structural ultrasound abnormalities were retrospectively enrolled. All participants were divided into groups with or without adverse obstetric history. We summarized the distribution of non-structural ultrasound abnormalities, calculated the overall and stratified detection rates of P/LP CNVs and VUS, and compared differences between groups.

Results: The mean maternal age was 28.73 ± 3.59 years; 22.0% had a positive history. Abnormal ultrasound soft markers accounted for 82.6% of cases, followed by fetal growth restriction (12.3%) and abnormal amniotic fluid volume (4.0%). The overall detection rates were 5.7% for P/LP CNVs and 9.1% for VUS. The highest detection rate of P/LP CNVs was observed in fetuses with abnormal amniotic fluid volume (10.5%), while the highest detection rate of VUS was seen in abnormal ultrasound soft markers (9.2%). The combined detection rate of P/LP and VUS differed among different types of isolated abnormal ultrasound soft markers, with tricuspid regurgitation, persistent right umbilical vein and persistent left superior vena cava showing higher detection rates. No significant differences in overall P/LP CNV and VUS rates were found between women with and without adverse pregnancy history (p > 0.05).

Conclusion: Non-advanced age pregnant women with fetal non-structural ultrasound abnormalities carry a non-negligible risk of P/LP CNVs and VUS. Different ultrasound soft markers present distinct CNV detection rates. Adverse obstetric history does not alter the P/LP CNVs and VUS detection rate.

Related

  1. Non-visualization of the inferior thyroid arteries on B-mode ultrasound is associated with structural inferior thyroid artery abnormalities and an adverse vascular phenotype
    Mauro Amato, Roberta Baetta, Beatrice Frigerio +30
    International Journal of Cardiology. Heart & VasculaturePeer-reviewedCC BY-NC 4.0Full textCardiovascular medicinePMC
  2. Pregnant Women's Experiences of Obstetric Abdominal Ultrasound: A Qualitative Study Exploring Emotional, Cognitive, and Relational Dimensions.
    Ayse Sezer Balci, Cigdem Can Bayrak, Meliha Akpınar Alaoglu
    Healthcare (Basel, Switzerland)Peer-reviewedCC BYFull textObstetrics, gynaecology & paediatricsEurope PMC
  3. The correlation between surgical, anaesthetic and obstetric workforce and surgical volume: a modelling study.
    Yuki Julius Ng, Alex J van Duinen, Håkon A Bolkan +3
    Frontiers in health servicesPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  4. Improving Immediate Postpartum Detection of Obstetric Anal Sphincter Injury: Added Diagnostic Value of Impedance Spectroscopy Following Clinical Assessment
    M. Uchman Musielak, K. Kleczkowska, I. Sudol Szopinska +1
    medRxivPreprintAll rights reservedFull text1 citedObstetrics, gynaecology & paediatricsmedRxiv
  5. Ensuring Safe and Responsible Use of Artificial Intelligence in Medical Imaging: Pitfalls and Practical Solutions through the Lens of Obstetric Ultrasound.
    Rishika Chanian, Ramachandran Thiruvengadam, Bapu Koundinya Desiraju
    The Indian journal of radiology & imagingPeer-reviewedCC BY-NC-NDFull textEpidemiology & public healthEurope PMC
BibTeX
@article{lin2026study,
  title = {{Study on copy number variant detection results of 472 fetuses with non-structural ultrasound abnormalities in non-advanced age pregnant women and the correlation with adverse obstetric history}},
  author = {Lifang Lin and Heming Wu and Zhiyuan Zheng and Ping Chen and Jianwen Lian and Shuxian Huang and Liubing Lan},
  journal = {Frontiers in Genetics},
  year = {2026},
  month = oct,
  doi = {10.3389/fgene.2026.1895948},
  url = {https://doi.org/10.3389/fgene.2026.1895948},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Study on copy number variant detection results of 472 fetuses with non-structural ultrasound abnormalities in non-advanced age pregnant women and the correlation with adverse obstetric history
AU  - Lifang Lin
AU  - Heming Wu
AU  - Zhiyuan Zheng
AU  - Ping Chen
AU  - Jianwen Lian
AU  - Shuxian Huang
AU  - Liubing Lan
PY  - 2026
DA  - 2026/10/30
JO  - Frontiers in Genetics
DO  - 10.3389/fgene.2026.1895948
UR  - https://doi.org/10.3389/fgene.2026.1895948
AB  - Objective: To investigate copy number variant (CNV) results in 472 fetuses with non-structural ultrasound abnormalities among pregnant women under 35 years, and analyze the association between adverse obstetric history and pathogenic/likely pathogenic (P/LP) CNVs and variants of uncertain significance (VUS).  Methods: A total of 472 pregnant women aged <35 years with fetal non-structural ultrasound abnormalities were retrospectively enrolled. All participants were divided into groups with or without adverse obstetric history. We summarized the distribution of non-structural ultrasound abnormalities, calculated the overall and stratified detection rates of P/LP CNVs and VUS, and compared differences between groups.  Results: The mean maternal age was 28.73 ± 3.59 years; 22.0% had a positive history. Abnormal ultrasound soft markers accounted for 82.6% of cases, followed by fetal growth restriction (12.3%) and abnormal amniotic fluid volume (4.0%). The overall detection rates were 5.7% for P/LP CNVs and 9.1% for VUS. The highest detection rate of P/LP CNVs was observed in fetuses with abnormal amniotic fluid volume (10.5%), while the highest detection rate of VUS was seen in abnormal ultrasound soft markers (9.2%). The combined detection rate of P/LP and VUS differed among different types of isolated abnormal ultrasound soft markers, with tricuspid regurgitation, persistent right umbilical vein and persistent left superior vena cava showing higher detection rates. No significant differences in overall P/LP CNV and VUS rates were found between women with and without adverse pregnancy history (p > 0.05).  Conclusion: Non-advanced age pregnant women with fetal non-structural ultrasound abnormalities carry a non-negligible risk of P/LP CNVs and VUS. Different ultrasound soft markers present distinct CNV detection rates. Adverse obstetric history does not alter the P/LP CNVs and VUS detection rate.
SN  - 1664-8021
ER  -