Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BY 4.0Medicine

Computer-assisted Taylor spatial frame for correcting malalignment after unilateral external fixation of tibial fractures

  1. 1Department of Traumatic Orthopaedics, Tianjin Hospital, Tianjin University, Tianjin, China.

Abstract

This study aimed to evaluate the clinical efficacy of computer-assisted Taylor spatial frame (TSF) for correcting malalignment after unilateral external fixation (UEF) of tibial fractures. This retrospective cohort study included 18 patients with tibial misalignment after UEF between February 2019 and February 2024. Using the TSF technique, X-ray parameters (deformity, frame, and mounting) were entered into software to generate a six-axis correction prescription. Reduction time, number of X-ray exposures, total external fixation duration, clinical fracture healing time, complications, and functional recovery were recorded. The Wilcoxon signed-rank test was used to compare preoperative and final visual analogue scale (VAS) scores because the paired differences were not normally distributed; data are presented as mean (range) or median (interquartile range [IQR]). All 18 patients were followed up for a mean of 14.9 months (range: 12–18 months). Satisfactory reduction was achieved in all cases after TSF adjustment. Mean reduction time was 19.0 minutes (range, 15–24 minutes), and patients received a mean of 1.4 X-ray exposures (range, 1–3). Clinical fracture healing occurred after a mean of 24.0 weeks (range, 21–29 weeks), and total external fixation lasted a mean of 25.2 weeks (range, 22–30 weeks). Johner-Wruhs ratings at final follow-up were excellent in 15 patients and good in 3 (100% excellent/good). Median VAS scores improved from 7 (IQR, 6–8) before surgery to 1 (IQR, 0–2) at final follow-up (Wilcoxon signed-rank test, Z = −3.77, P < .001). Superficial pin tract infections developed in 3 patients (16.7%; 3/18) and were controlled with oral antibiotics and dressing changes. No patient had deep infection, pin loosening, nonunion, or bone exposure. In this small, single-arm retrospective cohort, all 18 patients achieved satisfactory reduction with computer-assisted TSF, and adjustment times were short. No patient underwent secondary open reduction or fixation. These preliminary findings suggest that TSF may serve as a feasible minimally invasive option for correcting early malalignment following UEF of tibial fractures; however, multicenter controlled studies with longer follow-up are needed to confirm these results.

Related

  1. Endplate-to-endplate cement contact and 24-month outcomes after unilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a single-center retrospective cohort study
    Kaiqiang Zhang, Li Xia, Zhenbin Wang
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  2. AI-assisted reporting improves diagnostic concordance and reduces turnaround time in CT evaluation of rib fractures
    Chun Xiong, Yiting Hu, Xinmeng Yu +1
    American Journal of Translational ResearchPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  3. Use of Artificial Dermis Associated With Vacuum-Assisted Closure in the Management of Open Fractures in a Low-Income Setting: a Report of Two Cases
    Journal of the American Academy of Orthopaedic Surgeons. Global research & reviewsPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMC
  4. Arthroscopic-assisted uni-portal spinal surgery versus unilateral biportal endoscopy for lumbar degenerative diseases: a systematic review and meta-analysis of clinical outcomes and complications
    Jianbo Yan, Lixin Deng, Donger Zeng +1
    BMC Musculoskeletal DisordersPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  5. 16,648 reasons to live instead of dying by suicide: insights from a computer-assisted content analysis
    Philip Resnik, Rebecca Resnik, Katherine M. Schafer +2
    Scientific ReportsPeer-reviewedCC BY 4.0Full text2 citedPsychiatry & mental healthPMC
BibTeX
@article{zhao2026computerassisted,
  title = {{Computer-assisted Taylor spatial frame for correcting malalignment after unilateral external fixation of tibial fractures}},
  author = {Zhiming Zhao and Chengkuo Cai and Guoqi Ji and Weiguo Xu},
  journal = {Medicine},
  year = {2026},
  month = nov,
  doi = {10.1097/md.0000000000051508},
  url = {https://doi.org/10.1097/md.0000000000051508},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Computer-assisted Taylor spatial frame for correcting malalignment after unilateral external fixation of tibial fractures
AU  - Zhiming Zhao
AU  - Chengkuo Cai
AU  - Guoqi Ji
AU  - Weiguo Xu
PY  - 2026
DA  - 2026/11/06
JO  - Medicine
DO  - 10.1097/md.0000000000051508
UR  - https://doi.org/10.1097/md.0000000000051508
AB  - This study aimed to evaluate the clinical efficacy of computer-assisted Taylor spatial frame (TSF) for correcting malalignment after unilateral external fixation (UEF) of tibial fractures. This retrospective cohort study included 18 patients with tibial misalignment after UEF between February 2019 and February 2024. Using the TSF technique, X-ray parameters (deformity, frame, and mounting) were entered into software to generate a six-axis correction prescription. Reduction time, number of X-ray exposures, total external fixation duration, clinical fracture healing time, complications, and functional recovery were recorded. The Wilcoxon signed-rank test was used to compare preoperative and final visual analogue scale (VAS) scores because the paired differences were not normally distributed; data are presented as mean (range) or median (interquartile range [IQR]). All 18 patients were followed up for a mean of 14.9 months (range: 12–18 months). Satisfactory reduction was achieved in all cases after TSF adjustment. Mean reduction time was 19.0 minutes (range, 15–24 minutes), and patients received a mean of 1.4 X-ray exposures (range, 1–3). Clinical fracture healing occurred after a mean of 24.0 weeks (range, 21–29 weeks), and total external fixation lasted a mean of 25.2 weeks (range, 22–30 weeks). Johner-Wruhs ratings at final follow-up were excellent in 15 patients and good in 3 (100% excellent/good). Median VAS scores improved from 7 (IQR, 6–8) before surgery to 1 (IQR, 0–2) at final follow-up (Wilcoxon signed-rank test, Z = −3.77, P < .001). Superficial pin tract infections developed in 3 patients (16.7%; 3/18) and were controlled with oral antibiotics and dressing changes. No patient had deep infection, pin loosening, nonunion, or bone exposure. In this small, single-arm retrospective cohort, all 18 patients achieved satisfactory reduction with computer-assisted TSF, and adjustment times were short. No patient underwent secondary open reduction or fixation. These preliminary findings suggest that TSF may serve as a feasible minimally invasive option for correcting early malalignment following UEF of tibial fractures; however, multicenter controlled studies with longer follow-up are needed to confirm these results.
SN  - 0025-7974
SN  - 1536-5964
ER  -