Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 59 min ago
Peer-reviewedCC BYUltrasound in Medicine and Biology

Advancements in Noncontrast Ultrasound Imaging for Low-Velocity Flow: A Technical Review and Clinical Applications in Vascular Medicine

Abstract

Visualizing the arterial tree using ultrasound, from the aorta to the small vessels, has significantly improved over time due to advances in ultrasound imaging technology. Initially limited to exploring the major vessels, ultrasound analysis has made considerable progress with enhanced image quality. While injecting microbubbles as a contrast agent partially addresses this limitation, its use is constrained by the need for intravenous injection, making the examination more complex and time-consuming. To address these drawbacks, new commercial modes have emerged, distinct from conventional color- and power-Doppler modes, offering the ability to analyze slow flows and, consequently, microvascularization. These dedicated imaging modes include B-flow TM , E-flow TM , Superb Microvascular Imaging (SMI TM ), Micro Flow Imaging (MFI TM ), MV-Flow TM , Detective Flow Imaging (DFI TM ), Micro-V TM , and Angio PLUS imaging TM . Although these modes share similar objectives, they are based on different technologies, each with its own specific characteristics. The exact algorithms behind these modes vary and are proprietary but rely on a combination of approaches to reduce tissue clutter and electronic noise while improving sensitivity to slower-flow Doppler signals. This review aims to explain the technological basis of these "microvascular flow imaging modes" (MVFI) currently clinically available in vascular imaging to the physician and sonographer specialized in vascular ultrasound, discussing their current limitations and potential applications in vascular medicine.

Related

  1. Recent advancements on innovative technologies and applications for non-destructive monitoring of tomato quality
    Yirui Huang, Jiahao Gu, Mingyu Yang +4
    Frontiers in plant sciencePeer-reviewedCC BYFull textPlant biologyEurope PMC
  2. Frequency modulated semi-continuous wave Doppler ultrasound: A novel method for the detection of scatterer velocity and range using wearable ultrasound instrumentation
    C. M. Delaney, A. Bashatah, A. Aher +4
    bioRxivPreprintAll rights reservedFull textSystems & synthetic biologybioRxiv
  3. Applications of functional ultrasound brain-computer interfaces in neurological diseases: research progress based on neurovascular coupling
    Chengshan Zhang
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0Full textNeuroscienceCrossrefEurope PMCPMC
  4. Low-intensity focused ultrasound for neuromodulation: mechanisms, parameters, and emerging clinical applications—a critical review
    Dongsheng Liu, Kai Yang, Weihua Cheng +8
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0Full textNeuroscienceFrontiersCrossrefEurope PMC
  5. Advancements in vaccines against cancer stem cells (CSCs)
    Aayush, Yasaman Talebiashtiany, Khadijat Abubakar Bobbo +2
    American Journal of Cancer ResearchPeer-reviewedLicence not statedFull textImmunologyPMC
BibTeX
@article{seddiki2026advancements,
  title = {{Advancements in Noncontrast Ultrasound Imaging for Low-Velocity Flow: A Technical Review and Clinical Applications in Vascular Medicine}},
  author = {Rayan Seddiki and Tristan Mirault and Jonas Sitruk and Nassim Mohamedi and Emmanuel Messas and Mathieu Pernot and Jérôme Baranger and Guillaume Goudot},
  journal = {Ultrasound in Medicine and Biology},
  year = {2026},
  month = nov,
  doi = {10.1016/j.ultrasmedbio.2025.03.001},
  url = {https://hal.science/hal-05867332v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Advancements in Noncontrast Ultrasound Imaging for Low-Velocity Flow: A Technical Review and Clinical Applications in Vascular Medicine
AU  - Rayan Seddiki
AU  - Tristan Mirault
AU  - Jonas Sitruk
AU  - Nassim Mohamedi
AU  - Emmanuel Messas
AU  - Mathieu Pernot
AU  - Jérôme Baranger
AU  - Guillaume Goudot
PY  - 2026
DA  - 2026/11/16
JO  - Ultrasound in Medicine and Biology
DO  - 10.1016/j.ultrasmedbio.2025.03.001
UR  - https://hal.science/hal-05867332v1
AB  - Visualizing the arterial tree using ultrasound, from the aorta to the small vessels, has significantly improved over time due to advances in ultrasound imaging technology. Initially limited to exploring the major vessels, ultrasound analysis has made considerable progress with enhanced image quality. While injecting microbubbles as a contrast agent partially addresses this limitation, its use is constrained by the need for intravenous injection, making the examination more complex and time-consuming. To address these drawbacks, new commercial modes have emerged, distinct from conventional color- and power-Doppler modes, offering the ability to analyze slow flows and, consequently, microvascularization. These dedicated imaging modes include B-flow TM , E-flow TM , Superb Microvascular Imaging (SMI TM ), Micro Flow Imaging (MFI TM ), MV-Flow TM , Detective Flow Imaging (DFI TM ), Micro-V TM , and Angio PLUS imaging TM . Although these modes share similar objectives, they are based on different technologies, each with its own specific characteristics. The exact algorithms behind these modes vary and are proprietary but rely on a combination of approaches to reduce tissue clutter and electronic noise while improving sensitivity to slower-flow Doppler signals. This review aims to explain the technological basis of these "microvascular flow imaging modes" (MVFI) currently clinically available in vascular imaging to the physician and sonographer specialized in vascular ultrasound, discussing their current limitations and potential applications in vascular medicine.
SN  - 0301-5629
SN  - 1879-291X
ER  -