Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 8 min ago
Peer-reviewedCC BY-NC-ND 4.0Endoscopic Ultrasound

Comparison of 19-gauge FNA and 22-gauge FNB needles for the EUS-guided fine-needle aspiration of the lymphadenopathy and malignant lymphoma diagnosis: A multicenter retrospective study

9 more authors
8 affiliations
  1. 1Department of Gastroenterology, Matsunami General Hospital, Gifu, Japan
  2. 2First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan
  3. 3Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan
  4. 4Department of Pathology, Matsunami General Hospital, Gifu, Japan
  5. 5Department of Pathology, Gifu Municipal Hospital, Gifu, Japan
  6. 6Department of Hematology, Matsunami General Hospital, Gifu, Japan
  7. 7Division of Gastroenterology, Department of Medicine, Shiga University of Medical Science, Shiga, Japan
  8. 8Third Department of Internal Medicine, University of Toyama, Toyama, Japan.

Abstract

Background and Objectives:: EUS-guided fine-needle aspiration (EUS-FNA) using a 19-gauge FNA needle can safely obtain sufficient tissue samples for the evaluation of lymphadenopathy. FNB needles can also provide adequate tissue, and 22-gauge needles are generally easier to puncture than 19-gauge needles. This study aimed to compare the diagnostic performance of 19-gauge FNA and 22-gauge FNB needles for the diagnosis of lymphadenopathy.

Methods:: Among the 411 patients with lymphadenopathy, 221 underwent an EUS-FNA procedure using 19-gauge FNA or 22-gauge FNB needles. Patient characteristics, puncture procedures, and the accuracy of the cytological and histological diagnoses of lymphadenopathy were analyzed.

Results:: There were 116 and 105 patients in the 19-gauge FNA and 22-gauge FNB groups, respectively. The median lymph node size was significantly larger in the 19-gauge FNA group (29 mm vs. 23 mm, P < 0.01). Cytological and histological accuracies were significantly higher in the 19-gauge FNA group (91% vs. 63%, P < 0.01; 93% vs. 82%, P = 0.01). Multivariate logistic regression analysis showed that the use of 19-gauge FNA was significantly associated with diagnostic accuracy (cytology: odds ratio = 5.72, P < 0.01; histology: odds ratio = 3.38, P < 0.01). For malignant lymphoma diagnosis, immunohistochemical evaluation rates were similar between groups, whereas flow cytometry and cytogenetic sensitivities were significantly higher with 19-gauge FNA (90% vs. 55%, P < 0.01; and 68% vs. 14%, P < 0.01). Post-puncture infection was observed in only 1 patient in the 19-gauge FNA group.

Conclusion:: The use of 19-gauge FNA needles appeared to be a good option for diagnosing lymphadenopathy, considering that no significant difference was observed in the occurrence of adverse events.

Related

  1. Comparison of a model combining conventional ultrasonography and strain elastography with ACR TI-RADS for reducing unnecessary fine-needle aspiration in solid-predominant partially cystic thyroid nodules: a multicenter study.
    Yuguo Wang, Wangxing Huang, Hanzhong Qi +4
    Gland surgeryPeer-reviewedCC BY-NC-NDFull textEndocrinology & metabolismEurope PMCPMC
  2. Silicone lymphadenopathy of the axilla: a potential for misdiagnosis as metastatic carcinoma on fine-needle aspiration cytology
    Nah Ihm Kim, Hyo-Jae Lee, Ji Shin Lee
    Journal of Pathology and Translational MedicinePeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaPMC
  3. Is endobronchial ultrasound-guided bronchoscopy (EBUS) transbronchial needle aspiration (TBNA) enough for the diagnosis of mediastinal lymphadenopathy? A cohort analysis
    Kimberly Taha, Patrice Roll, Julie Tronchetti +2
    Respiratory Medicine and ResearchPeer-reviewedCC BY 4.0Full textGeneral biologyOncologyHAL
  4. Aspiration of a Peanut Mimicking a Malignant Tumor
    Kodai Komatsu, Tsutomu Hachiya, Masanobu Kimoto +1
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyJ-STAGE
  5. Machine learning–based differentiation of malignant and non-malignant pleural effusion in lung cancer patients: a multicenter retrospective study
    Qi Cai, Yahui Wu, Jun Wang +5
    BMC CancerPeer-reviewedCC BY-NC-ND 4.0Full textOncologyPMCDOAJ
BibTeX
@article{okuno2026comparison,
  title = {{Comparison of 19-gauge FNA and 22-gauge FNB needles for the EUS-guided fine-needle aspiration of the lymphadenopathy and malignant lymphoma diagnosis: A multicenter retrospective study}},
  author = {Mitsuru Okuno and Shinya Uemura and Tsuyoshi Mukai and Fumiya Kataoka and Keisuke Iwata and Ryuichi Tezuka and Yuhei Iwasa and Takuya Koizumi and Yosuke Ohashi and Shota Iwata and Akinori Maruta and Keisuke Kawashima and Yusuke Kito and Naoki Watanabe and Takeshi Hara and Hisashi Tsurumi and Takuji Iwashita and Eiichi Tomita and Ichiro Yasuda and Hisataka Moriwaki and Masahito Shimizu},
  journal = {Endoscopic Ultrasound},
  year = {2026},
  month = sep,
  doi = {10.1097/eus.0000000000000211},
  url = {https://doi.org/10.1097/eus.0000000000000211},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Comparison of 19-gauge FNA and 22-gauge FNB needles for the EUS-guided fine-needle aspiration of the lymphadenopathy and malignant lymphoma diagnosis: A multicenter retrospective study
AU  - Mitsuru Okuno
AU  - Shinya Uemura
AU  - Tsuyoshi Mukai
AU  - Fumiya Kataoka
AU  - Keisuke Iwata
AU  - Ryuichi Tezuka
AU  - Yuhei Iwasa
AU  - Takuya Koizumi
AU  - Yosuke Ohashi
AU  - Shota Iwata
AU  - Akinori Maruta
AU  - Keisuke Kawashima
AU  - Yusuke Kito
AU  - Naoki Watanabe
AU  - Takeshi Hara
AU  - Hisashi Tsurumi
AU  - Takuji Iwashita
AU  - Eiichi Tomita
AU  - Ichiro Yasuda
AU  - Hisataka Moriwaki
AU  - Masahito Shimizu
PY  - 2026
DA  - 2026/09/01
JO  - Endoscopic Ultrasound
DO  - 10.1097/eus.0000000000000211
UR  - https://doi.org/10.1097/eus.0000000000000211
AB  - Background and Objectives:: EUS-guided fine-needle aspiration (EUS-FNA) using a 19-gauge FNA needle can safely obtain sufficient tissue samples for the evaluation of lymphadenopathy. FNB needles can also provide adequate tissue, and 22-gauge needles are generally easier to puncture than 19-gauge needles. This study aimed to compare the diagnostic performance of 19-gauge FNA and 22-gauge FNB needles for the diagnosis of lymphadenopathy.  Methods:: Among the 411 patients with lymphadenopathy, 221 underwent an EUS-FNA procedure using 19-gauge FNA or 22-gauge FNB needles. Patient characteristics, puncture procedures, and the accuracy of the cytological and histological diagnoses of lymphadenopathy were analyzed.  Results:: There were 116 and 105 patients in the 19-gauge FNA and 22-gauge FNB groups, respectively. The median lymph node size was significantly larger in the 19-gauge FNA group (29 mm vs. 23 mm, P < 0.01). Cytological and histological accuracies were significantly higher in the 19-gauge FNA group (91% vs. 63%, P < 0.01; 93% vs. 82%, P = 0.01). Multivariate logistic regression analysis showed that the use of 19-gauge FNA was significantly associated with diagnostic accuracy (cytology: odds ratio = 5.72, P < 0.01; histology: odds ratio = 3.38, P < 0.01). For malignant lymphoma diagnosis, immunohistochemical evaluation rates were similar between groups, whereas flow cytometry and cytogenetic sensitivities were significantly higher with 19-gauge FNA (90% vs. 55%, P < 0.01; and 68% vs. 14%, P < 0.01). Post-puncture infection was observed in only 1 patient in the 19-gauge FNA group.  Conclusion:: The use of 19-gauge FNA needles appeared to be a good option for diagnosing lymphadenopathy, considering that no significant difference was observed in the occurrence of adverse events.
SN  - 2303-9027
SN  - 2226-7190
ER  -