Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 13 min ago
Peer-reviewedCC BY 4.0PLOS One

Asthma Intervention with Residential Ventilation and Air Cleaner (AIRVAC) Study: A 4-arm parallel-group randomized controlled trial protocol

  1. 1Department of Civil Engineering, University of Texas at Arlington, Arlington, Texas, United States of America
  2. 2Department of Earth and Environmental Sciences, University of Texas at Arlington, Arlington, Texas, United States of America
  3. 3Rebuilding Together North Texas, Plano, Texas, United States of America

Abstract

Background: Evidence linking exposure to airborne particulate and gaseous pollutants, as well as mold spores, with asthma control and severity is well established. A growing body of literature has demonstrated that ventilation and air filtration can improve indoor air quality (IAQ); however, clinical evidence on their comparative health impacts remains limited. Therefore, this trial aims to evaluate the long-term effectiveness of energy recovery ventilators (ERVs) and portable air cleaners (PACs) in reducing indoor air pollutants and mold levels and improving health outcomes in individuals with asthma. Secondary objectives includes associations between housing conditions, occupant behaviors, indoor environmental exposures, and asthma-related health outcomes. Methods: The AIRVAC study is a single-blind, placebo-controlled, 4-arm, parallel-group, randomized controlled trial, with a pre-intervention period of up to 1 year and a 1-year post-intervention period. Children aged 5–17 years and adults with physician-diagnosed asthma will be recruited from more than 80 households across the Dallas-Fort Worth (DFW) area in Texas. Following the pre-intervention period, each household will be randomized to receive one of four different interventions midway through the study: (1) active ERVs, (2) sham ERVs, (3) active PACs, and (4) sham PACs. Primary health outcomes include asthma control; secondary outcomes include pulmonary function, asthma-related quality of life, stress, and sleep quality. Initial housing assessments will be conducted prior to the pre-intervention period to characterize occupant behaviors and housing-related factors that may contribute to asthma exacerbations and affect ERV installation. Environmental exposures will be assessed by combining measurements of indoor and outdoor air pollutants, including particulate matter (PM), nitrogen dioxide (NO2), carbon monoxide (CO), and volatile organic compounds (VOCs), as well as temperature, relative humidity, and indoor and outdoor mold, using low-cost and research-grade air quality sensors and mold sampling methods. Discussion: Findings from the AIRVAC study will provide important evidence on the comparative effects of residential ventilation and air cleaning interventions on IAQ, mold, and asthma-related health outcomes among children and adults with asthma. The study will also examine the relationships among housing characteristics, occupant behaviors, indoor environmental exposures, and asthma-related health outcomes, while providing insights into the operation and performance of residential ventilation and air cleaning interventions in vulnerable households.

Related

  1. Differential Impacts of Platelet-Rich Plasma and Hyaluronic Acid on miR-132 Modulation, Inflammatory Cytokines (IL-1β and IL-6), and Functional Recovery in Knee Osteoarthritis: A Randomized Controlled Trial
    Hendrian Chaniago, Muhammad Nasrum Massi, Muhammad Andry Usman +1
    International Journal of Molecular and Cellular MedicinePeer-reviewedCC BY-NCFull textGenetics & genomicsGeneral chemistryDOAJ
  2. Model-Based Assessment of Geogenic Radon Exposure in Chaco Canyon and Adjacent Ancestral Puebloan Residential Settings
    Reynold E. Silber, Elizabeth A Silber, Carman Melendrez +1
    EarthArXivPreprintCC BY-NC-ND 4.0Full textEvolutionary biologyEnvironmental chemistryEarthArXiv
  3. Digital-Twin Attention-Augmented Adaptive Model Predictive Control for Degradation-Aware Residential Battery Energy Management
    Muhammed Cavus
    BatteriesPeer-reviewedCC BY 4.0Electrochemistry & energyCrossref
  4. Research on dust control and ventilation parameter optimization in roadhead mining based on response surface methodology
    Xiaokun Zhao, Yuting Zhang, Jun Ge +3
    PLOS OnePeer-reviewedCC BY 4.0Full textMaterials & polymersStatisticsPLOS
  5. Smoke characteristics of conveyor-belt fires in U-shaped belt-conveyor roadways under different ventilation velocities
    Jian Ding, Jinzhong Wu
    PLOS OnePeer-reviewedCC BY 4.0Full textMaterials & polymersAtmospheric science & meteorologyPLOS
BibTeX
@article{kang2026asthma,
  title = {{Asthma Intervention with Residential Ventilation and Air Cleaner (AIRVAC) Study: A 4-arm parallel-group randomized controlled trial protocol}},
  author = {Insung Kang and Semi Park and Yidan Zhang and Steven Tanner McCullough and Tia LaFavor and Yike Shen and June Young Park},
  journal = {PLOS One},
  year = {2026},
  month = sep,
  doi = {10.1371/journal.pone.0358221},
  url = {https://doi.org/10.1371/journal.pone.0358221},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Asthma Intervention with Residential Ventilation and Air Cleaner (AIRVAC) Study: A 4-arm parallel-group randomized controlled trial protocol
AU  - Insung Kang
AU  - Semi Park
AU  - Yidan Zhang
AU  - Steven Tanner McCullough
AU  - Tia LaFavor
AU  - Yike Shen
AU  - June Young Park
PY  - 2026
DA  - 2026/09/25
JO  - PLOS One
DO  - 10.1371/journal.pone.0358221
UR  - https://doi.org/10.1371/journal.pone.0358221
AB  - Background: Evidence linking exposure to airborne particulate and gaseous pollutants, as well as mold spores, with asthma control and severity is well established. A growing body of literature has demonstrated that ventilation and air filtration can improve indoor air quality (IAQ); however, clinical evidence on their comparative health impacts remains limited. Therefore, this trial aims to evaluate the long-term effectiveness of energy recovery ventilators (ERVs) and portable air cleaners (PACs) in reducing indoor air pollutants and mold levels and improving health outcomes in individuals with asthma. Secondary objectives includes associations between housing conditions, occupant behaviors, indoor environmental exposures, and asthma-related health outcomes. Methods: The AIRVAC study is a single-blind, placebo-controlled, 4-arm, parallel-group, randomized controlled trial, with a pre-intervention period of up to 1 year and a 1-year post-intervention period. Children aged 5–17 years and adults with physician-diagnosed asthma will be recruited from more than 80 households across the Dallas-Fort Worth (DFW) area in Texas. Following the pre-intervention period, each household will be randomized to receive one of four different interventions midway through the study: (1) active ERVs, (2) sham ERVs, (3) active PACs, and (4) sham PACs. Primary health outcomes include asthma control; secondary outcomes include pulmonary function, asthma-related quality of life, stress, and sleep quality. Initial housing assessments will be conducted prior to the pre-intervention period to characterize occupant behaviors and housing-related factors that may contribute to asthma exacerbations and affect ERV installation. Environmental exposures will be assessed by combining measurements of indoor and outdoor air pollutants, including particulate matter (PM), nitrogen dioxide (NO2), carbon monoxide (CO), and volatile organic compounds (VOCs), as well as temperature, relative humidity, and indoor and outdoor mold, using low-cost and research-grade air quality sensors and mold sampling methods. Discussion: Findings from the AIRVAC study will provide important evidence on the comparative effects of residential ventilation and air cleaning interventions on IAQ, mold, and asthma-related health outcomes among children and adults with asthma. The study will also examine the relationships among housing characteristics, occupant behaviors, indoor environmental exposures, and asthma-related health outcomes, while providing insights into the operation and performance of residential ventilation and air cleaning interventions in vulnerable households.
SN  - 1932-6203
ER  -