Evaluation of six different tests for Schistosoma haematobium diagnosis in a near-elimination setting: A prospective observational diagnostic accuracy study
7 affiliations
- 1Swiss Tropical and Public Health Institute, Allschwil, Switzerland
- 2University of Basel, Basel, Switzerland
- 3Public Health Laboratory–Ivo de Carneri, Chake Chake, Pemba, United Republic of Tanzania
- 4Enaiblers AB, Uppsala, Sweden
- 5Leiden University Center for Infectious Diseases, Leiden, the Netherlands
- 6Natural History Museum, London, United Kingdom
- 7Ghent University, Gent, Belgium
Abstract
Background: Accurate diagnostic tools are needed in schistosomiasis elimination settings to determine prevalence thresholds for assigning or stopping interventions, guide pre- and post-elimination surveillance, and verify whether elimination has been reached. We assessed the accuracy of six different diagnostic tests in Pemba, Tanzania, a setting approaching Schistosoma haematobium elimination. Methodology: A prospective diagnostic accuracy study was conducted from February to April 2025. From an initial cross-sectional single-day urine filtration (UF)-microscopy screening of 784 students, 69 S. haematobium-positive and 212 negative students were randomly selected for longitudinal follow-up. Four additional urine samples collected over four different days, were available from 262/281 participants and subjected to UF-microscopy. One sample per participant was analysed in parallel with five additional diagnostics: microscopy-based artificial intelligence (AI) scanner, Schistosoma-ITS-2 qPCR, S. haematobium-Dra-1 recombinase polymerase amplification (RPA), Hemastix reagent strips, and up-converting particle lateral flow circulating anodic antigen assay (UCP-LF CAA). We assessed the sensitivity and specificity of the different diagnostics, using 5-day UF-microscopy as reference test. Principal findings: A total of 85/262 participants were S. haematobium-positive using 5-day UF-microscopy. Directly compared with the reference test, the sensitivity for single-sample examination was: AI scanner: 76.7% (95% confidence interval (CI): 71.0-82.5%), qPCR: 76.0% (95% CI: 70.1-81.4%), UF-microscopy: 61.2% (95% CI: 55.3-67.1%), RPA: 56.1% (95% CI: 50.0-62.2%), Hemastix: 44.6% (95% CI: 38.5-50.7%), and UCP-LF CAA: 30.6% (95% CI: 24.9-36.3%). Sensitivity increased with increasing infection intensity. The specificity of all investigated diagnostics was >92%, except for qPCR and RPA. Conclusions/significance: In near-elimination settings, multiple-day urine examination with standard UF-microscopy substantially improves case detection but is operationally challenging. For single-sample testing, among the six diagnostics investigated, the AI scanner proved to be the most accurate. Hence, the AI scanner might offer a promising alternative for research, clinical and programme use, but requires further validation in other settings and cost-effectiveness analyses. Author summary: As countries progress towards the schistosomiasis elimination goals set by the World Health Organization for 2030, case numbers and infection intensities decrease, which brings about diagnostic challenges. Indeed, accurate diagnostic tools are needed to precisely determine where to assign or stop interventions, implement test-and-treat approaches, guide surveillance and enable verification of elimination. We conducted a prospective, head-to-head accuracy evaluation of six diagnostic tests, ranging from standard urine filtration (UF)-microscopy and haematuria assessment to advanced molecular and antigen tests and a new artificial intelligence (AI) scanner for egg microscopy. All tests were evaluated using the same urine sample, for Schistosoma haematobium detection in a near-elimination setting. We showed that examining multiple-day urine samples from the same individual with standard UF-microscopy, substantially increased the number of cases, especially when infection intensities were light. With 5-day UF-microscopy as the reference test, the specificity of all investigated single-sample tests was >92%, except for qPCR and S. haematobium-Dra-1 recombinase polymerase amplification. Sensitivity was >60% for the novel AI scanner, qPCR and UF-microscopy. Sensitivity of all tests increased with increasing infection intensity. Schistosomiasis control and elimination programmes relying on single-sample UF-microscopy risk missing a substantial proportion of infections, impeding intervention decisions and jeopardising elimination targets. Multiple-day UF-microscopy improves case detection but is operationally challenging. For single-sample testing in near-elimination settings, an AI scanner offers a promising alternative for research, clinical and programme use, warranting further cost-effectiveness and implementation studies.
Related
- Subclinical hepatorenal biomarker alterations and urogenital indicators in Schistosoma haematobium-infected School-Aged Children in Sene West District, Ghana
- Sex-specific correlates of Schistosoma haematobium infection in a rural Zambian setting: A pilot study focusing on immune and hematological factors
- Impact of praziquantel treatment and early reinfection patterns in a mixed Schistosoma mansoni and Schistosoma haematobium infection focus in the Democratic Republic of Congo
- Schistosoma haematobium infection among school age children in two peri-urban areas of Lusaka, Zambia: A cross-sectional study
- Development of a multiplex quantitative real-time PCR (qPCR) assay for simultaneous detection of Schistosoma haematobium and high-risk human papillomaviruses
BibTeX
@article{ndum2026evaluation,
title = {{Evaluation of six different tests for Schistosoma haematobium diagnosis in a near-elimination setting: A prospective observational diagnostic accuracy study}},
author = {Naomi C. Ndum and Said M. Ali and Mohammed N. Ali and John Bergelin and Jan Hattendorf and Pytsje T. Hoekstra and Lisette van Lieshout and Tom Pennance and Khamis R. Suleiman and Jürg Utzinger and Peter Ward and Bonnie L. Webster and Stefanie Knopp},
journal = {PLOS Neglected Tropical Diseases},
year = {2026},
month = sep,
doi = {10.1371/journal.pntd.0014066},
url = {https://journals.plos.org/plosntds/article?id=10.1371/journal.pntd.0014066},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Evaluation of six different tests for Schistosoma haematobium diagnosis in a near-elimination setting: A prospective observational diagnostic accuracy study
AU - Naomi C. Ndum
AU - Said M. Ali
AU - Mohammed N. Ali
AU - John Bergelin
AU - Jan Hattendorf
AU - Pytsje T. Hoekstra
AU - Lisette van Lieshout
AU - Tom Pennance
AU - Khamis R. Suleiman
AU - Jürg Utzinger
AU - Peter Ward
AU - Bonnie L. Webster
AU - Stefanie Knopp
PY - 2026
DA - 2026/09/15
JO - PLOS Neglected Tropical Diseases
DO - 10.1371/journal.pntd.0014066
UR - https://journals.plos.org/plosntds/article?id=10.1371/journal.pntd.0014066
AB - Background: Accurate diagnostic tools are needed in schistosomiasis elimination settings to determine prevalence thresholds for assigning or stopping interventions, guide pre- and post-elimination surveillance, and verify whether elimination has been reached. We assessed the accuracy of six different diagnostic tests in Pemba, Tanzania, a setting approaching Schistosoma haematobium elimination. Methodology: A prospective diagnostic accuracy study was conducted from February to April 2025. From an initial cross-sectional single-day urine filtration (UF)-microscopy screening of 784 students, 69 S. haematobium-positive and 212 negative students were randomly selected for longitudinal follow-up. Four additional urine samples collected over four different days, were available from 262/281 participants and subjected to UF-microscopy. One sample per participant was analysed in parallel with five additional diagnostics: microscopy-based artificial intelligence (AI) scanner, Schistosoma-ITS-2 qPCR, S. haematobium-Dra-1 recombinase polymerase amplification (RPA), Hemastix reagent strips, and up-converting particle lateral flow circulating anodic antigen assay (UCP-LF CAA). We assessed the sensitivity and specificity of the different diagnostics, using 5-day UF-microscopy as reference test. Principal findings: A total of 85/262 participants were S. haematobium-positive using 5-day UF-microscopy. Directly compared with the reference test, the sensitivity for single-sample examination was: AI scanner: 76.7% (95% confidence interval (CI): 71.0-82.5%), qPCR: 76.0% (95% CI: 70.1-81.4%), UF-microscopy: 61.2% (95% CI: 55.3-67.1%), RPA: 56.1% (95% CI: 50.0-62.2%), Hemastix: 44.6% (95% CI: 38.5-50.7%), and UCP-LF CAA: 30.6% (95% CI: 24.9-36.3%). Sensitivity increased with increasing infection intensity. The specificity of all investigated diagnostics was >92%, except for qPCR and RPA. Conclusions/significance: In near-elimination settings, multiple-day urine examination with standard UF-microscopy substantially improves case detection but is operationally challenging. For single-sample testing, among the six diagnostics investigated, the AI scanner proved to be the most accurate. Hence, the AI scanner might offer a promising alternative for research, clinical and programme use, but requires further validation in other settings and cost-effectiveness analyses. Author summary: As countries progress towards the schistosomiasis elimination goals set by the World Health Organization for 2030, case numbers and infection intensities decrease, which brings about diagnostic challenges. Indeed, accurate diagnostic tools are needed to precisely determine where to assign or stop interventions, implement test-and-treat approaches, guide surveillance and enable verification of elimination. We conducted a prospective, head-to-head accuracy evaluation of six diagnostic tests, ranging from standard urine filtration (UF)-microscopy and haematuria assessment to advanced molecular and antigen tests and a new artificial intelligence (AI) scanner for egg microscopy. All tests were evaluated using the same urine sample, for Schistosoma haematobium detection in a near-elimination setting. We showed that examining multiple-day urine samples from the same individual with standard UF-microscopy, substantially increased the number of cases, especially when infection intensities were light. With 5-day UF-microscopy as the reference test, the specificity of all investigated single-sample tests was >92%, except for qPCR and S. haematobium-Dra-1 recombinase polymerase amplification. Sensitivity was >60% for the novel AI scanner, qPCR and UF-microscopy. Sensitivity of all tests increased with increasing infection intensity. Schistosomiasis control and elimination programmes relying on single-sample UF-microscopy risk missing a substantial proportion of infections, impeding intervention decisions and jeopardising elimination targets. Multiple-day UF-microscopy improves case detection but is operationally challenging. For single-sample testing in near-elimination settings, an AI scanner offers a promising alternative for research, clinical and programme use, warranting further cost-effectiveness and implementation studies.
SN - 1935-2735
ER -