Skip to content
DraconiticResearch
Search Sources API
210,095 studies31 sourcesUpdated 37 min ago
Peer-reviewedCC BY 4.0Journal of Interventional Cardiac Electrophysiology

Atrial fibrillation ablation using real-time three-dimensional transesophageal echocardiography as the primary intraprocedural imaging modality: a single-center feasibility study

4 affiliations
  1. 1Sentara Cardiology Specialists, Norfolk, VA USA
  2. 2Sentara Cardiovascular Research Institute, Norfolk, VA USA
  3. 3University of Virginia, Charlottesville, VA USA
  4. 4Macon & Joan Brock Virginia Health Sciences at Old Dominion University, Norfolk, VA USA

Abstract

Background: Intracardiac echocardiography (ICE) is commonly used during atrial fibrillation (AF) ablation to facilitate transseptal access, catheter positioning, and intraprocedural safety monitoring but adds procedural cost and requires additional vascular access. Real-time three-dimensional transesophageal echocardiography (3D TEE) offers high-quality imaging without disposable intravascular catheters; however, its use as a primary intraprocedural imaging modality during contemporary AF ablation has been limited. This study evaluated the feasibility, safety, and procedural efficiency of using real-time 3D TEE in place of ICE for intraprocedural guidance during AF ablation.

Methods: This single-center feasibility study included 128 consecutive AF ablation procedures performed over an eight-month pilot period using real-time 3D TEE as the primary intraprocedural imaging modality. TEE was used for transseptal puncture guidance, catheter visualization, and intraprocedural safety monitoring. Procedural characteristics, fluoroscopy utilization, acute procedural success, complications, and same-day discharge rates were analyzed.

Results: Acute procedural ablation success was achieved in all cases. Procedures included de novo and repeat ablations, cases requiring lesion sets beyond pulmonary vein isolation, and concomitant left atrial appendage occlusion. No major acute complications, including pericardial effusion requiring intervention, clinically apparent esophageal injury, cerebrovascular events, or in-hospital mortality, were observed. Median total procedure time was 40 min (interquartile range (IQR) 32–50), median fluoroscopy time was 8.6 min (IQR 6.2–11.0), and median radiation dose was 39.1 mGy (IQR 23.2–78.9). Same-day discharge was achieved in 87.5% of procedures.

Conclusion: Real-time 3D TEE can be used as the primary intraprocedural imaging modality for AF ablation, providing effective guidance for transseptal access, catheter positioning, and safety monitoring without reliance on ICE. In centers with advanced echocardiographic expertise and appropriate training frameworks, this approach may represent a viable alternative to ICE with potential advantages in procedural workflow and resource utilization.

Capsule Summary: Real-time three-dimensional transesophageal echocardiography can be used as the primary intraprocedural imaging modality during atrial fibrillation ablation, providing effective guidance for catheter manipulation and safety monitoring while avoiding disposable intracardiac echocardiography catheters and additional vascular access.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02355-1.

Related

  1. Complex cardiac schwannoma surgery: Navigation with perioperative 3-dimensional transesophageal echocardiography
    Jayakumar Thanathu Krishnan Nair, Manjusha N. Pillai, Adinarayanan Kishore Nochur +1
    JTCVS techniquesPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Feasibility and Operator-Reported Utility of Transesophageal Lung Ultrasound As an Adjunct to Resuscitative Transesophageal Echocardiography in the Evaluation of Shock: A Multicenter Observational Study
    Vladyslav Dieiev, Pedro D. Salinas, Felipe Teran +10
    Critical Care MedicinePeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
  3. Robotic resection of cardiac papillary fibroelastoma guided by three-dimensional transesophageal echocardiography: a case report.
    Fernando Hideki Sakamoto, Ana Clara Tude Rodrigues, Claudio Henrique Fischer +9
    Einstein (Sao Paulo, Brazil)Peer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Development and evaluation of a transesophageal echocardiography–derived left atrial appendage structure–function coupling index across the atrial fibrillation disease continuum
    Jianbo Zhu, Chen Ni, Yangnan Ruan +5
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossref
  5. Acute Changes in Left Atrial Appendage Flow Velocity During Pulsed Field Ablation: An Intraprocedural Intracardiac Echocardiography Study
    Y. Pan, P. Osmancik, T. Knize +6
    medRxivPreprintAll rights reservedFull textCardiovascular medicinemedRxiv
BibTeX
@article{willaford2026atrial,
  title = {{Atrial fibrillation ablation using real-time three-dimensional transesophageal echocardiography as the primary intraprocedural imaging modality: a single-center feasibility study}},
  author = {Casey Willaford and Malcolm Woollett and Ian Woollett},
  journal = {Journal of Interventional Cardiac Electrophysiology},
  year = {2026},
  month = may,
  doi = {10.1007/s10840-026-02355-1},
  url = {https://doi.org/10.1007/s10840-026-02355-1},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Atrial fibrillation ablation using real-time three-dimensional transesophageal echocardiography as the primary intraprocedural imaging modality: a single-center feasibility study
AU  - Casey Willaford
AU  - Malcolm Woollett
AU  - Ian Woollett
PY  - 2026
DA  - 2026/05/21
JO  - Journal of Interventional Cardiac Electrophysiology
DO  - 10.1007/s10840-026-02355-1
UR  - https://doi.org/10.1007/s10840-026-02355-1
AB  - Background: Intracardiac echocardiography (ICE) is commonly used during atrial fibrillation (AF) ablation to facilitate transseptal access, catheter positioning, and intraprocedural safety monitoring but adds procedural cost and requires additional vascular access. Real-time three-dimensional transesophageal echocardiography (3D TEE) offers high-quality imaging without disposable intravascular catheters; however, its use as a primary intraprocedural imaging modality during contemporary AF ablation has been limited. This study evaluated the feasibility, safety, and procedural efficiency of using real-time 3D TEE in place of ICE for intraprocedural guidance during AF ablation.  Methods: This single-center feasibility study included 128 consecutive AF ablation procedures performed over an eight-month pilot period using real-time 3D TEE as the primary intraprocedural imaging modality. TEE was used for transseptal puncture guidance, catheter visualization, and intraprocedural safety monitoring. Procedural characteristics, fluoroscopy utilization, acute procedural success, complications, and same-day discharge rates were analyzed.  Results: Acute procedural ablation success was achieved in all cases. Procedures included de novo and repeat ablations, cases requiring lesion sets beyond pulmonary vein isolation, and concomitant left atrial appendage occlusion. No major acute complications, including pericardial effusion requiring intervention, clinically apparent esophageal injury, cerebrovascular events, or in-hospital mortality, were observed. Median total procedure time was 40 min (interquartile range (IQR) 32–50), median fluoroscopy time was 8.6 min (IQR 6.2–11.0), and median radiation dose was 39.1 mGy (IQR 23.2–78.9). Same-day discharge was achieved in 87.5% of procedures.  Conclusion: Real-time 3D TEE can be used as the primary intraprocedural imaging modality for AF ablation, providing effective guidance for transseptal access, catheter positioning, and safety monitoring without reliance on ICE. In centers with advanced echocardiographic expertise and appropriate training frameworks, this approach may represent a viable alternative to ICE with potential advantages in procedural workflow and resource utilization.  Capsule Summary: Real-time three-dimensional transesophageal echocardiography can be used as the primary intraprocedural imaging modality during atrial fibrillation ablation, providing effective guidance for catheter manipulation and safety monitoring while avoiding disposable intracardiac echocardiography catheters and additional vascular access.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s10840-026-02355-1.
SN  - 1383-875X
SN  - 1572-8595
ER  -