Comparison of Five Assays for Rapid Antimicrobial Susceptibility Testing (RAST), Including Disk Diffusion, MIC-Based Systems, and Genotypic Methods: A Prospective Evaluation
5 affiliations
- 1Diagnostic and Research Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, Graz, Austria
- 2Division of Infectious Diseases, Department of Internal Medicine, Medical University of Graz, Graz, Austria
- 3Institute of Hospital Hygiene and Microbiology, Styrian Hospital Corporation, Graz, Austria
- 4Institute for Medical Informatics, Statistics and Documentation, Medical University of Graz, Graz, Austria
- 5Institute of Laboratory Medicine and Microbiology, Protestant Hospital of Bethel Foundation, Campus Bielefeld-Bethel, University Hospital OWL of Bielefeld University, Bielefeld, Germany
Abstract
Introduction: Early and targeted therapy is pivotal for the outcome of bloodstream infection, a life-threatening condition with high mortality. EUCAST developed a protocol for rapid antimicrobial susceptibility testing (RAST) that allows testing directly from positive blood cultures (BCs). Recently, fully automated minimum inhibitory concentration (MIC)-based systems were introduced. This is the first study to compare two of these systems with agar-based RAST and genotypic resistance testing.
Methods: Ninety-seven Gram-negative BCs were prospectively analyzed using five different RAST assays. Agar-based RAST according to EUCAST was performed using conventional disk diffusion (DD) and a total laboratory automation solution (BD Kiestra), with reads at 4, 6, and 8 h. MIC-based, fully automated RAST was performed using VITEK Reveal (bioMérieux) and dRAST (Quantamatrix). Identification and genotypic resistance testing were additionally analyzed with the Biofire BCID2 multiplex PCR (bioMérieux).
Results: A total of 6715 genotypic and phenotypic results were compared with reference methods. Biofire achieved 100% sensitivity and specificity for species identification and resistance gene detection; 0–28% of BCs were unanalyzable due to missing RAST breakpoints. Categorical agreement ranged from 82.2% (4 h DD) to 95.4% (Reveal). Agar-based RAST yielded significantly more results in the area of technical uncertainty than other methods. Kiestra-based DD outperformed conventional DD after short incubation. Reveal had the highest rate of false-susceptible results (2.4%), particularly for penicillin. dRAST tended to false-resistant results (3.4%), particularly with motile organisms like Proteus mirabilis.
Conclusions: Automation of RAST provides more usable results than conventional DD, but each assay has specific weaknesses that users need to be aware of.
Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s40121-026-01451-z.
Related
- Comparison of antimicrobial susceptibility testing methods for aztreonam-avibactam against NDM-producing Enterobacterales clinical isolates
- Clinical Profile of Patients With Pseudomonas aeruginosa Infection and Antimicrobial Susceptibility Patterns of Pseudomonas aeruginosa: A Cross-sectional Prospective Study From a Tertiary Care Hospital in Central India.
- An evaluation of piperacillin-tazobactam antimicrobial stewardship intervention and association with β-lactam susceptibility in Pseudomonas aeruginosa and Enterobacter cloacae complex
- Reducing time-to-result in bloodstream infections: comparative evaluation of VITEK® REVEAL™ and QuickMIC® for rapid phenotypic antimicrobial susceptibility testing
- Multisite clinical evaluation of the iFAST rapid antimicrobial susceptibility test direct from positive blood cultures containing gram-negative organisms
BibTeX
@article{uitz2026comparison,
title = {{Comparison of Five Assays for Rapid Antimicrobial Susceptibility Testing (RAST), Including Disk Diffusion, MIC-Based Systems, and Genotypic Methods: A Prospective Evaluation}},
author = {Christine Uitz and David Siebenhofer and Kristin Aurenhammer and Robert Krause and Michael Kroißenbrunner and Thomas Kuenzer and Ivo Steinmetz and Karl Dichtl},
journal = {Infectious Diseases and Therapy},
year = {2026},
month = oct,
doi = {10.1007/s40121-026-01451-z},
url = {https://doi.org/10.1007/s40121-026-01451-z},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Comparison of Five Assays for Rapid Antimicrobial Susceptibility Testing (RAST), Including Disk Diffusion, MIC-Based Systems, and Genotypic Methods: A Prospective Evaluation
AU - Christine Uitz
AU - David Siebenhofer
AU - Kristin Aurenhammer
AU - Robert Krause
AU - Michael Kroißenbrunner
AU - Thomas Kuenzer
AU - Ivo Steinmetz
AU - Karl Dichtl
PY - 2026
DA - 2026/10/05
JO - Infectious Diseases and Therapy
DO - 10.1007/s40121-026-01451-z
UR - https://doi.org/10.1007/s40121-026-01451-z
AB - Introduction: Early and targeted therapy is pivotal for the outcome of bloodstream infection, a life-threatening condition with high mortality. EUCAST developed a protocol for rapid antimicrobial susceptibility testing (RAST) that allows testing directly from positive blood cultures (BCs). Recently, fully automated minimum inhibitory concentration (MIC)-based systems were introduced. This is the first study to compare two of these systems with agar-based RAST and genotypic resistance testing. Methods: Ninety-seven Gram-negative BCs were prospectively analyzed using five different RAST assays. Agar-based RAST according to EUCAST was performed using conventional disk diffusion (DD) and a total laboratory automation solution (BD Kiestra), with reads at 4, 6, and 8 h. MIC-based, fully automated RAST was performed using VITEK Reveal (bioMérieux) and dRAST (Quantamatrix). Identification and genotypic resistance testing were additionally analyzed with the Biofire BCID2 multiplex PCR (bioMérieux). Results: A total of 6715 genotypic and phenotypic results were compared with reference methods. Biofire achieved 100% sensitivity and specificity for species identification and resistance gene detection; 0–28% of BCs were unanalyzable due to missing RAST breakpoints. Categorical agreement ranged from 82.2% (4 h DD) to 95.4% (Reveal). Agar-based RAST yielded significantly more results in the area of technical uncertainty than other methods. Kiestra-based DD outperformed conventional DD after short incubation. Reveal had the highest rate of false-susceptible results (2.4%), particularly for penicillin. dRAST tended to false-resistant results (3.4%), particularly with motile organisms like Proteus mirabilis. Conclusions: Automation of RAST provides more usable results than conventional DD, but each assay has specific weaknesses that users need to be aware of. Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1007/s40121-026-01451-z.
SN - 2193-8229
SN - 2193-6382
ER -