Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 15 min ago
Peer-reviewedCC BY-NCJournal of Korean medical science

Diagnostic Accuracy of Anti-Müllerian Hormone for Polycystic Ovary Syndrome: An Updated Systematic Review and Meta-Analysis.

6 affiliations
  1. 1Department of Obstetrics and Gynecology, Korea University College of Medicine, Seoul, Korea.
  2. 2Department of Obstetrics and Gynecology, Korea University Anam Hospital, Seoul, Korea.
  3. 3Department of Obstetrics and Gynecology, Pusan National University School of Medicine, Busan, Korea.
  4. 4Biomedical Research Institute, Pusan National University Hospital, Busan, Korea.
  5. 5Cochrane Korea, Institute for Evidence-Based Medicine, Korea University College of Medicine, Seoul, Korea. [email protected].
  6. 6Department of Obstetrics and Gynecology, Korea University Anam Hospital, Seoul, Korea. [email protected].

Abstract

Background

The 2023 international evidence-based guideline for polycystic ovary syndrome (PCOS) conditionally recommended serum anti-Müllerian hormone (AMH) as an alternative to ultrasound for diagnosing polycystic ovarian morphology (PCOM) in adults, marking a significant shift in diagnostic practice. However, the diagnostic accuracy of AMH remains debated, particularly regarding its utility as a standalone test, its application across diverse populations, and its use in adolescents.Methods

A systematic review and meta-analysis was conducted following PRISMA guidelines. Major electronic databases, including PubMed, Embase, and the Cochrane Library, were searched for diagnostic accuracy studies published until November 2024, and studies evaluating serum AMH against the Rotterdam criteria for PCOS or ultrasound-defined PCOM were included. A bivariate random-effects model was used to pool sensitivity and specificity with 95% confidence intervals (CIs) for three key questions: AMH for 1) PCOS diagnosis in adults, 2) PCOM diagnosis in adults, and 3) PCOS diagnosis in adolescents. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the risk of bias.Results

For adult PCOS diagnosis, 83 studies (n = 33,376) were included, yielding a pooled sensitivity of 0.81 (95% CI, 0.78-0.83) and a specificity of 0.89 (95% CI, 0.86-0.91). For adult PCOM diagnosis, six studies (n = 11,436) provided a pooled sensitivity of 0.79 (95% CI, 0.70-0.86) and a specificity of 0.88 (95% CI, 0.77-0.94). In contrast, the analysis for adolescent PCOS (11 studies, n = 1,090) revealed a significantly lower accuracy, with a pooled sensitivity of 0.66 (95% CI, 0.58-0.73) and a specificity of 0.78 (95% CI, 0.71-0.83). Substantial heterogeneity was observed across all analyses.Conclusion

The current, updated meta-analysis confirms that serum AMH is a highly specific and moderately sensitive biomarker for diagnosing PCOM and PCOS in adults, supporting its role as an adjunctive diagnostic tool. However, its utility as a standalone test is limited by significant heterogeneity; in addition, its diagnostic performance is further limited in adolescents, providing evidence against its use in such population. Future efforts must focus on the international standardization of AMH assays and the development of population-specific reference values to enhance its clinical utility.

Related

  1. Diagnostic accuracy of point-of-care ultrasound for the detection of acute aortic syndrome in the emergency department: a systematic review and meta-analysis
    Sin Tung Li Rebecca, KC Hung Kevin, Wang Xinyu +4
    World Journal of Emergency MedicinePeer-reviewedLicence not statedFull textGeneral medicinePMC
  2. Comprehensive genomic profiling can improve diagnostic accuracy and Mullerian cancer treatment planning: A case report.
    Natalia Garcia Dutton, Chinmayi Aryasomayajula, Nedas Matulionis +3
    Gynecologic oncology reportsPeer-reviewedCC BYFull textOncologyEurope PMCPMC
  3. Diagnostic accuracy of tongue diagnosis for stroke syndrome differentiation in traditional Chinese medicine: a systematic review, meta-analysis, and narrative synthesis of artificial intelligence-assisted models.
    Yibo Huang, Jiashun Yin, Siyuan Shao +3
    Frontiers in neurologyPeer-reviewedCC BYFull textNeurologyEurope PMCCrossref
  4. Polycystic ovary syndrome with metabolic syndrome and diabetes: a systematic review and meta-analysis
    Bita Pourahmad, Mostafa Majidnia, Nadia Saniee +2
    Journal of Ovarian ResearchPeer-reviewedCC BY-NC-ND 4.0Full textObstetrics, gynaecology & paediatricsPMC
  5. Diagnostic accuracy of the appendicitis inflammatory response (AIR) score for acute appendicitis during pregnancy: A systematic review and diagnostic meta-analysis
    Yasaman Tavakoli, Behdad Ghanami, Azad Alimohammadi +1
    Surgery in practice and sciencePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{jeong2026diagnostic,
  title = {{Diagnostic Accuracy of Anti-Müllerian Hormone for Polycystic Ovary Syndrome: An Updated Systematic Review and Meta-Analysis.}},
  author = {Hye Gyeong Jeong and Hyun Joo Lee and Ki-Jin Ryu and Eun Hee Yu and Jong Kil Joo and Hyun Jung Kim and Hyuntae Park},
  journal = {Journal of Korean medical science},
  year = {2026},
  month = nov,
  doi = {10.3346/jkms.2026.41.e295},
  url = {https://europepmc.org/article/MED/43074584},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Diagnostic Accuracy of Anti-Müllerian Hormone for Polycystic Ovary Syndrome: An Updated Systematic Review and Meta-Analysis.
AU  - Hye Gyeong Jeong
AU  - Hyun Joo Lee
AU  - Ki-Jin Ryu
AU  - Eun Hee Yu
AU  - Jong Kil Joo
AU  - Hyun Jung Kim
AU  - Hyuntae Park
PY  - 2026
DA  - 2026/11/23
JO  - Journal of Korean medical science
DO  - 10.3346/jkms.2026.41.e295
UR  - https://europepmc.org/article/MED/43074584
AB  - Background  The 2023 international evidence-based guideline for polycystic ovary syndrome (PCOS) conditionally recommended serum anti-Müllerian hormone (AMH) as an alternative to ultrasound for diagnosing polycystic ovarian morphology (PCOM) in adults, marking a significant shift in diagnostic practice. However, the diagnostic accuracy of AMH remains debated, particularly regarding its utility as a standalone test, its application across diverse populations, and its use in adolescents.Methods  A systematic review and meta-analysis was conducted following PRISMA guidelines. Major electronic databases, including PubMed, Embase, and the Cochrane Library, were searched for diagnostic accuracy studies published until November 2024, and studies evaluating serum AMH against the Rotterdam criteria for PCOS or ultrasound-defined PCOM were included. A bivariate random-effects model was used to pool sensitivity and specificity with 95% confidence intervals (CIs) for three key questions: AMH for 1) PCOS diagnosis in adults, 2) PCOM diagnosis in adults, and 3) PCOS diagnosis in adolescents. The Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to assess the risk of bias.Results  For adult PCOS diagnosis, 83 studies (n = 33,376) were included, yielding a pooled sensitivity of 0.81 (95% CI, 0.78-0.83) and a specificity of 0.89 (95% CI, 0.86-0.91). For adult PCOM diagnosis, six studies (n = 11,436) provided a pooled sensitivity of 0.79 (95% CI, 0.70-0.86) and a specificity of 0.88 (95% CI, 0.77-0.94). In contrast, the analysis for adolescent PCOS (11 studies, n = 1,090) revealed a significantly lower accuracy, with a pooled sensitivity of 0.66 (95% CI, 0.58-0.73) and a specificity of 0.78 (95% CI, 0.71-0.83). Substantial heterogeneity was observed across all analyses.Conclusion  The current, updated meta-analysis confirms that serum AMH is a highly specific and moderately sensitive biomarker for diagnosing PCOM and PCOS in adults, supporting its role as an adjunctive diagnostic tool. However, its utility as a standalone test is limited by significant heterogeneity; in addition, its diagnostic performance is further limited in adolescents, providing evidence against its use in such population. Future efforts must focus on the international standardization of AMH assays and the development of population-specific reference values to enhance its clinical utility.
SN  - 1598-6357
ER  -