Skip to content
DraconiticResearch
Search Sources API
203,948 studies31 sourcesUpdated just now
Peer-reviewedCC BYScientific Reports

Venturi-effect ultrasonography for early detection of AVF stenosis: a prospective multicenter study

  1. 1Department of Ultrasound Medicine, Chengdu University of Traditional Chinese Medicine Affiliated Fifth People’s Hospital
  2. 2Department of Ultrasound Medicine, Clinical Medical College and The First Affiliated Hospital of Chengdu Medical College

Abstract

This study aims to evaluate the diagnostic value of the Venturi effect combined with conventional ultrasonographic indicators for the early detection of arteriovenous fistula (AVF) stenosis in hemodialysis patients. A total of 169 patients with suspected AVF dysfunction were enrolled from January 2019 to June 2024 at the Department of Nephrology. Ultrasound parameters assessed including the minimal lumen diameter (MD) at the suspected stenosis site of the cephalic vein, the Venturi effect presence, peak systolic velocity (PSV), peak systolic velocity ratio (PSVR), brachial artery resistance index (BA-RI), and the flow volume difference (ΔFV). The diagnostic performance of each individual conventional parameter was compared with that of its combination with the Venturi effect for early AVF stenosis detection. Among the 169 patients, 158 were confirmed as stenotic. The conventional ultrasound indicators with the highest sensitivity and specificity for diagnosing AVF stenosis were MD, with a sensitivity of 93.7% and specificity of 93.8%. The area under the receiver operating characteristic curve (AUC) of individual parameters was ranked from highest to lowest as follows: AUC_MD > AUC_BA-RI > AUC_PSV > AUC_PSVR > AUC_ΔFV. After combining the Venturi effect with each indicator, diagnostic sensitivity for AVF stenosis improved to varying degrees. Among them, the diagnostic performance of PSV, PSVR and ΔFV has significantly improved (P < 0.005). The Venturi effect combined with conventional ultrasonographic indicators demonstrates high diagnostic efficacy in the early diagnosis of AVF stenosis.

Related

  1. Dynamic assessment of renal resistive index using point-of-care ultrasonography for early detection of sepsis-induced acute kidney injury: A multicenter clinical trial protocol
    Zongfang Ren, Lingling Wang, Jinxi Yue +3
    PLOS OnePeer-reviewedCC BYFull textGeneral biochemistryGeneral biologyPLOSEurope PMCPMC
  2. Study protocol for a prospective multicenter longitudinal cohort study on progression of moderate aortic valve stenosis, the MODAS Study
    R. Phinicarides, K. Klein, C. Jung +11
    medRxivPreprintCC BY-NC-NDFull textCardiovascular medicinemedRxiv
  3. Deep learning based detection of active pulmonary tuberculosis from chest radiographs in a retrospective prospective multicenter study
    Abudouresuli Tuersun, Saimaitikari Abudoubari, Jingxu Xu +8
    iSciencePeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyCell PressCrossrefPMCEurope PMC
  4. Preoperative staging of gastric cancer: a prospective comparison of gastric filling ultrasonography and enhanced CT with implications for surgical decision-making
    Xinxin Qin, Junmei Zhao, Litao Ge +3
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Risk stratification by circulating tumor DNA-based pretreatment genomic profile and post-operative molecular residual disease detection in resectable colorectal oligometastases: PRECISION, a prospective multicenter study
    S. Kobayashi, T. Takamoto, A. Shiomi +17
    ESMO OpenPeer-reviewedCC BY-NC-ND 4.0Full textOncologyPMC
BibTeX
@article{chen2026venturieffect,
  title = {{Venturi-effect ultrasonography for early detection of AVF stenosis: a prospective multicenter study}},
  author = {Yi-Xu Chen and Bo Gou and Ji-Cheng Zhang and Wang Jie and Yang-Li Liu and Ru-Fang Jiang and Ben-Tian Liu and Jian Liu},
  journal = {Scientific Reports},
  year = {2026},
  month = jul,
  doi = {10.1038/s41598-026-62364-y},
  url = {https://doi.org/10.1038/s41598-026-62364-y},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Venturi-effect ultrasonography for early detection of AVF stenosis: a prospective multicenter study
AU  - Yi-Xu Chen
AU  - Bo Gou
AU  - Ji-Cheng Zhang
AU  - Wang Jie
AU  - Yang-Li Liu
AU  - Ru-Fang Jiang
AU  - Ben-Tian Liu
AU  - Jian Liu
PY  - 2026
DA  - 2026/07/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-62364-y
UR  - https://doi.org/10.1038/s41598-026-62364-y
AB  - This study aims to evaluate the diagnostic value of the Venturi effect combined with conventional ultrasonographic indicators for the early detection of arteriovenous fistula (AVF) stenosis in hemodialysis patients. A total of 169 patients with suspected AVF dysfunction were enrolled from January 2019 to June 2024 at the Department of Nephrology. Ultrasound parameters assessed including the minimal lumen diameter (MD) at the suspected stenosis site of the cephalic vein, the Venturi effect presence, peak systolic velocity (PSV), peak systolic velocity ratio (PSVR), brachial artery resistance index (BA-RI), and the flow volume difference (ΔFV). The diagnostic performance of each individual conventional parameter was compared with that of its combination with the Venturi effect for early AVF stenosis detection. Among the 169 patients, 158 were confirmed as stenotic. The conventional ultrasound indicators with the highest sensitivity and specificity for diagnosing AVF stenosis were MD, with a sensitivity of 93.7% and specificity of 93.8%. The area under the receiver operating characteristic curve (AUC) of individual parameters was ranked from highest to lowest as follows: AUC_MD > AUC_BA-RI > AUC_PSV > AUC_PSVR > AUC_ΔFV. After combining the Venturi effect with each indicator, diagnostic sensitivity for AVF stenosis improved to varying degrees. Among them, the diagnostic performance of PSV, PSVR and ΔFV has significantly improved (P < 0.005). The Venturi effect combined with conventional ultrasonographic indicators demonstrates high diagnostic efficacy in the early diagnosis of AVF stenosis.
SN  - 2045-2322
ER  -