Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors

Abstract

This work presents high-resolution X-ray microtomography based on commercial off-the-shelf (COTS) CMOS image sensors as direct detectors. The system uses a microfocus X-ray source in cone-beam geometry, enabling both absorption-contrast imaging, thanks to the sensor s intrinsic resolution, and phase-contrast imaging, by adjusting the object-to-sensor distance. A dynamic flat-field correction algorithm mitigates radiation-induced sensor degradation during long acquisitions. The setup provides voxel sizes from 3.9 microns to 5.2 microns, with an effective spatial resolution (FWHM) as fine as 9.6 microns in magnified phase-contrast mode (1.33x) and 21 microns in non-magnified absorption-contrast mode. Phase contrast enhances visualization of soft tissue boundaries that are difficult to visualize using absorption-contrast imaging in the same experimental configuration.

Related

  1. Effects of X-ray absorption on grating-based and propagation-based phase-contrast imaging
    Jun Yang, Jun Qi, Hui Fang Zhang +1
    Optics ExpressPeer-reviewedLicence not statedApplied physics & instrumentationCrossref
  2. Characteristics of VHF and UHF band detection using Stark shifting in Rydberg-atom sensors
    Rajavardhan Talashila, Noah Schlossberger, David S. La Mantia +6
    arXivPreprintCC BY 4.0Full textAtomic, molecular & optical physicsOptics & photonicsarXiv
  3. Research status and prospects of dynamic perception and quantitative detection sensors for icing characteristics
    Han Shi, Mengjie Song, Xuan Zhang +12
    Cell Reports Physical SciencePeer-reviewedCC BYFull textGeneral physicsDOAJ
  4. On the influence of mechanical loadings on the porosities of structural epoxy adhesives joints by means of in-situ X-ray microtomography
    V. Dumont, C. Badulescu, G. Stamoulis +4
    International Journal of Adhesion and AdhesivesPeer-reviewedLicence not statedFull text22 citedGeneral physicsHAL
  5. Measurement of three-dimensional volumetric displacement fields in structural porous adhesive joints, under tensile and tensile-shear load, by means of in-situ X-ray microtomography
    C. Badulescu, V. Dumont, M. Diakhaté +5
    International Journal of Adhesion and AdhesivesPeer-reviewedLicence not stated3 citedGeneral physicsHAL
BibTeX
@misc{corzi2026absorption,
  title = {{Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors}},
  author = {Damian L. Corzi and Jose Lipovetzky and Fabricio Alcalde Bessia and German Mato and Andres Cicuttin and Maria L. Crespo and Martin Perez and Mariano Gomez Berisso},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2605.29808},
  eprint = {2605.29808},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2605.29808},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Absorption and Phase-Contrast Microtomography Using Direct X-Ray Detection With Commercial Off-The-Shelf CMOS Sensors
AU  - Damian L. Corzi
AU  - Jose Lipovetzky
AU  - Fabricio Alcalde Bessia
AU  - German Mato
AU  - Andres Cicuttin
AU  - Maria L. Crespo
AU  - Martin Perez
AU  - Mariano Gomez Berisso
PY  - 2026
DA  - 2026/10/15
PB  - arXiv
DO  - 10.48550/arxiv.2605.29808
UR  - https://arxiv.org/abs/2605.29808
AB  - This work presents high-resolution X-ray microtomography based on commercial off-the-shelf (COTS) CMOS image sensors as direct detectors. The system uses a microfocus X-ray source in cone-beam geometry, enabling both absorption-contrast imaging, thanks to the sensor s intrinsic resolution, and phase-contrast imaging, by adjusting the object-to-sensor distance. A dynamic flat-field correction algorithm mitigates radiation-induced sensor degradation during long acquisitions. The setup provides voxel sizes from 3.9 microns to 5.2 microns, with an effective spatial resolution (FWHM) as fine as 9.6 microns in magnified phase-contrast mode (1.33x) and 21 microns in non-magnified absorption-contrast mode. Phase contrast enhances visualization of soft tissue boundaries that are difficult to visualize using absorption-contrast imaging in the same experimental configuration.
ER  -