Intrathecal hyperbaric versus isobaric bupivacaine for caesarean delivery: A meta-analysis and trial sequential analysis
4 affiliations
- 1Department of Intensive Care Medicine and Anaesthetics, Wollongong Hospital, Australia
- 2Department of Anaesthetics, Blacktown Hospital, NSW Australia
- 3Department of Oncology, Wrexham Maelor Hospital, United Kingdom
- 4Department of Medicine, Goulburn Base Hospital, NSW Australia
Abstract
Background and Aims:: Intrathecal bupivacaine facilitates caesarean delivery and is available in two forms: isobaric or hyperbaric with differing pharmacokinetic profiles. This meta-analysis primarily aimed to compare the incidence of hypotension (defined as a drop ≥20% from baseline systolic or mean arterial pressure) when used in caesarean delivery.
Methods:: Randomised controlled trials (RCTs) comparing intrathecal isobaric and hyperbaric bupivacaine for caesarean delivery were identified from MEDLINE, Google Scholar, and Cochrane databases. Secondary outcomes included incidence of ephedrine use, nausea/vomiting, bradycardia, maximum block height, time to maximum block height, and offset of block. Jadad scores evaluated the trials' quality. RevMan statistical software® calculated the standardised mean difference with 95% confidence intervals for continuous variables. The Mantel–Haenszel test and a random effect model were used to calculate the odds ratio for dichotomous variables. Included articles were assessed for risk of bias and consistency with Grading of Recommendations Assessment, Development, and Evaluation guidelines.
Results:: Nineteen articles with 1501 patients were analysed with 722 patients receiving isobaric bupivacaine versus 779 receiving hyperbaric bupivacaine. There was no significant difference in the rates of hypotension [odds ratio (OR) 1.25, 95% confidence interval (CI) 0.63 to 2.46] or incidence of ephedrine use (OR 1.44, 95% CI 0.75 to 2.77). There was a faster onset of motor block with hyperbaric bupivacaine (standardised mean difference -0.46, 95% CI –0.86 to –0.05) but no other differences in secondary outcomes.
Conclusion:: Despite differences between isobaric and hyperbaric bupivacaine, neither caused a significantly higher incidence of hypotension. Both produce similar clinical profiles except for onset of motor block. High levels of heterogeneity between the studies indicate the need for focused RCTs on this topic.
Related
- A comparative study between hyperbaric prilocaine 2% versus hyperbaric bupivacaine 0.5% for intrathecal anesthesia in cesarean section.
- Dexmedetomidine Versus Dexamethasone as Adjuvants to Bupivacaine for Wound Infiltration After Caesarean Section Under Spinal Anaesthesia
- Switching from Hyperbaric Bupivacaine to Hyperbaric Prilocaine for Spinal Anesthesia in Elective Cesarean Delivery Within an Enhanced Recovery Pathway: An Exploratory Single-Center Before-and-After Study
- Pain Outcomes and Perioperative Cytokine Responses After Intrathecal Morphine or Erector Spinae Plane Block for Caesarean Delivery: A Prospective Observational Cohort Study
- Intrathecal Hydromorphone Combined with Transversalis Fascia Plane Block versus Patient-Conmintravenous Analgesia After Caesarean Delivery: A Randomised Controlled Trial
BibTeX
@article{tobin2026intrathecal,
title = {{Intrathecal hyperbaric versus isobaric bupivacaine for caesarean delivery: A meta-analysis and trial sequential analysis}},
author = {David Gregory Tobin and Arnab Banerjee and Madhuchanda Chatterjee and Anindya Banerjee},
journal = {Indian Journal of Anaesthesia},
year = {2026},
month = oct,
doi = {10.4103/ija.ija_838_26},
url = {https://doi.org/10.4103/ija.ija_838_26},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Intrathecal hyperbaric versus isobaric bupivacaine for caesarean delivery: A meta-analysis and trial sequential analysis
AU - David Gregory Tobin
AU - Arnab Banerjee
AU - Madhuchanda Chatterjee
AU - Anindya Banerjee
PY - 2026
DA - 2026/10/22
JO - Indian Journal of Anaesthesia
DO - 10.4103/ija.ija_838_26
UR - https://doi.org/10.4103/ija.ija_838_26
AB - Background and Aims:: Intrathecal bupivacaine facilitates caesarean delivery and is available in two forms: isobaric or hyperbaric with differing pharmacokinetic profiles. This meta-analysis primarily aimed to compare the incidence of hypotension (defined as a drop ≥20% from baseline systolic or mean arterial pressure) when used in caesarean delivery. Methods:: Randomised controlled trials (RCTs) comparing intrathecal isobaric and hyperbaric bupivacaine for caesarean delivery were identified from MEDLINE, Google Scholar, and Cochrane databases. Secondary outcomes included incidence of ephedrine use, nausea/vomiting, bradycardia, maximum block height, time to maximum block height, and offset of block. Jadad scores evaluated the trials' quality. RevMan statistical software® calculated the standardised mean difference with 95% confidence intervals for continuous variables. The Mantel–Haenszel test and a random effect model were used to calculate the odds ratio for dichotomous variables. Included articles were assessed for risk of bias and consistency with Grading of Recommendations Assessment, Development, and Evaluation guidelines. Results:: Nineteen articles with 1501 patients were analysed with 722 patients receiving isobaric bupivacaine versus 779 receiving hyperbaric bupivacaine. There was no significant difference in the rates of hypotension [odds ratio (OR) 1.25, 95% confidence interval (CI) 0.63 to 2.46] or incidence of ephedrine use (OR 1.44, 95% CI 0.75 to 2.77). There was a faster onset of motor block with hyperbaric bupivacaine (standardised mean difference -0.46, 95% CI –0.86 to –0.05) but no other differences in secondary outcomes. Conclusion:: Despite differences between isobaric and hyperbaric bupivacaine, neither caused a significantly higher incidence of hypotension. Both produce similar clinical profiles except for onset of motor block. High levels of heterogeneity between the studies indicate the need for focused RCTs on this topic.
SN - 0019-5049
SN - 0976-2817
ER -