Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 55 min ago
PreprintCC BY 4.0HAL

A hydraulic constitutive closure for reduced haemodynamic models with generalised-Newtonian rheology

Abstract

Blood is shear thinning, yet reduced haemodynamic models coupled to resolved three-dimensional domains typically represent their resistive elements using fixed-viscosity Poiseuille relations, leaving the rheology inconsistent across the coupling interface. A constitutive-to-resistance closure is introduced that carries a generalised-Newtonian rheology consistently into a reduced hydraulic model. Combining the constitutive law with the Weissenberg–Rabinowitsch–Mooney–Schofield relation for steady tube flow, the nonlinear pressure–flow response is written in Poiseuille form through an effective hydraulic viscosity depending only on the wall shear stress. Because the wall shear stress follows from the pressure drop, radius and path length through the axial momentum balance, the constitutive map is independent of vessel radius and effective path length: morphometry sets the operating wall stress, rheology the flow sustained at that stress. This separation gives a direct route from a constitutive law to a nonlinear reduced resistance, and permits the rheological state to be estimated before solving the coupled problem. Closed-form mappings are obtained for the power-law, Cross, Carreau–Yasuda and Quemada laws, with an analytical tangent for implicit coupling. In a coupled 0D–3D coronary model, the rheological correction is small near the high-shear plateau but appreciable under systolic compression: constant-viscosity resistances underestimate the cycle-averaged proximal effective viscosity by 7–24% and alter mean coronary inflow by 3.6–8.5%. Pressure in the resolved domain remains within 0.05% of the constant-viscosity result, whereas wall-shear-stress and viscous-dissipation fields differ by up to 28% and 79% in relative norm. Pressure agreement can therefore conceal substantial differences in local haemodynamics, and the reduced closure alone can materially alter predicted coronary flow and wall quantities.

Related

  1. Assessment of resting-state prefrontal haemodynamic fluctuation characteristics in male university students who have received curling training using fNIRS technology
    Tong Zhu, Lulu Wang, Zezhong Zhang +6
    Scientific ReportsPeer-reviewedCC BY 4.0Full textNeuroscienceCrossref
  2. Effect of palm oil and shea butter addition on chocolate rheology, aroma release and sensory perception: A mixture design of experiment approach
    Baptiste Molard, Isabelle Maraval, Zoé Deuscher +3
    Food ChemistryPeer-reviewedLicence not statedFull text4 citedGeneral biologyHAL
  3. PHEnotyping type 2 inflammation in chronic rhinosinusitis with nasal polyps (CRSwNP) using RHeology of sinonasal secretions and tissue EOsinophil mapping in the middle turbinate
    Valentin Favier, Zakaria Mohamed Lahmar, Ahmed Engi +5
    Research Square - PreprintPreprintCC BYFull textGeneral biologyHAL
  4. Ultrasound‐based haemodynamic force trajectories in a murine model of reversible pressure overload
    Peyton Day, Thomas Moore-Morris, Craig Goergen +1
    The Journal of PhysiologyPeer-reviewedCC BY 4.0Full textSystems & synthetic biologyCardiovascular medicineHAL
  5. ProFinder: Candidate constitutive promoter prediction across the bacterial tree for genetic tool development in non-model species
    A. Gautam, J. W. Marsh
    bioRxivPreprintAll rights reservedFull textMicrobiologybioRxiv
BibTeX
@misc{britopacheco2026hydraulic,
  title = {{A hydraulic constitutive closure for reduced haemodynamic models with generalised-Newtonian rheology}},
  author = {Carlos Brito-Pacheco and Milenko Espinosa and Ernesto Castillo and Scarlett Espinoza and Alfredo Parra-Lucares and Luis Berr and Oscar Ruz},
  howpublished = {HAL},
  year = {2026},
  month = sep,
  url = {https://hal.science/hal-05749403v1},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - A hydraulic constitutive closure for reduced haemodynamic models with generalised-Newtonian rheology
AU  - Carlos Brito-Pacheco
AU  - Milenko Espinosa
AU  - Ernesto Castillo
AU  - Scarlett Espinoza
AU  - Alfredo Parra-Lucares
AU  - Luis Berr
AU  - Oscar Ruz
PY  - 2026
DA  - 2026/09/14
PB  - HAL
UR  - https://hal.science/hal-05749403v1
AB  - Blood is shear thinning, yet reduced haemodynamic models coupled to resolved three-dimensional domains typically represent their resistive elements using fixed-viscosity Poiseuille relations, leaving the rheology inconsistent across the coupling interface. A constitutive-to-resistance closure is introduced that carries a generalised-Newtonian rheology consistently into a reduced hydraulic model. Combining the constitutive law with the Weissenberg–Rabinowitsch–Mooney–Schofield relation for steady tube flow, the nonlinear pressure–flow response is written in Poiseuille form through an effective hydraulic viscosity depending only on the wall shear stress. Because the wall shear stress follows from the pressure drop, radius and path length through the axial momentum balance, the constitutive map is independent of vessel radius and effective path length: morphometry sets the operating wall stress, rheology the flow sustained at that stress. This separation gives a direct route from a constitutive law to a nonlinear reduced resistance, and permits the rheological state to be estimated before solving the coupled problem. Closed-form mappings are obtained for the power-law, Cross, Carreau–Yasuda and Quemada laws, with an analytical tangent for implicit coupling. In a coupled 0D–3D coronary model, the rheological correction is small near the high-shear plateau but appreciable under systolic compression: constant-viscosity resistances underestimate the cycle-averaged proximal effective viscosity by 7–24% and alter mean coronary inflow by 3.6–8.5%. Pressure in the resolved domain remains within 0.05% of the constant-viscosity result, whereas wall-shear-stress and viscous-dissipation fields differ by up to 28% and 79% in relative norm. Pressure agreement can therefore conceal substantial differences in local haemodynamics, and the reduced closure alone can materially alter predicted coronary flow and wall quantities.
ER  -