Assessing effects of low-dose CT attenuation correction on quantification and image quality on a LAFOV PET system with a modified NEMA-IQ phantom.

5 affiliations
  1. 1Siemens Healthcare Limited, Camberley, UK.
  2. 2King's College London and Guy's & St Thomas' PET Centre, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  3. 3Department of Biomedical Computing, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  4. 4Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  5. 5Department of Imaging Physics and Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Abstract

Background

Over the past decades, efforts have been directed toward increasing the sensitivity of PET systems to enable low-dose PET imaging and shorter scan times. The Biograph Vision Quadra PET/CT scanner (Siemens Healthineers, Knoxville, TN, USA) combines an increased solid angle coverage with time of flight, enabling a significant reduction in administered activity. To fully benefit from low-dose PET imaging, the dose of the CT scan should ideally also be reduced.Purpose

The CT radiation dose can be reduced by lowering the tube voltage and exposure as well as by the use of tin filtration. Reducing the CT dose must be carefully aligned with any impact that changing CT image quality and quantitative metrics may have on the PET quantification, for example via linear attenuation coefficients. We evaluate the impact of low-dose CT protocols on the PET quantification in soft-tissue-like and bone-equivalent materials using a customized phantom.Methods

The phantom was assembled out of a NEMA-IQ phantom, several layers of saline and two bovine long bones, to simulate a patient positioned with arms down. A 10-min PET scan with 47 different accompanying CT scans was acquired. The CT tube voltage and exposure were varied between 70kVto140kV , with and without tin filtration, and 7mAsto400mAs , respectively. The effect of the different CT parameters on the PET image quality and quantitative accuracy was assessed via several quantitative metrics, including standardized uptake value (SUV) and signal-to-noise ratio, along with the CT dose length product (DLP).Results

The recorded DLP values suggest that using all tube voltages except 140kV combined with exposures in the range of 7mAsto30mAs , can result in dose savings of ≥ 80% compared to a typical clinical protocol ( 120kV , 50mAs ). Compared to this typical protocol, HU differed more in bone ( 10%to40% difference) than in soft tissue ( 1%to30% difference), and more streak artefacts and photon starvation were seen when configuring low tube voltages and exposures, with an accompanying increase in CT noise. The observed artefacts were transferred with low intensity to the PET images via the attenuation map. The SUVmean remained within 2% of the SUVmean of the typical clinical protocol for most tested protocols. The presence of artefacts in the CT images had a bigger impact on PET quantification in both soft tissue and bone ( SUVmean difference of 10%to20% ) than any difference in HU. Protocols that resulted in artefacts showed an increased inaccuracy in attenuation correction and scatter estimation, as assessed via the "lung" residual error (up to 10%to20% increase).Conclusions

Even for low-dose CT protocols, PET quantification remained consistent in all NEMA-IQ spheres for many materials. Beam hardening and photon starvation in the CT image are likely to occur in specific body regions such as hips, shoulders or the abdomen for an arms-down scan and these effects had a bigger impact on the quantification than any difference in HU in both soft tissue and bone. This therefore should be considered when selecting suitable CT imaging parameters.

Related

  1. Deep learning–based quantification of muscle volume and attenuation and their associations with preinjury ambulatory status in patients with hip fractures
    Tomoki Asano, Keisuke Uemura, Sotaro Kono +10
    Osteoporosis and sarcopeniaPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Improved 2.5D-UNet pseudo-CT generation for attenuation correction in PET imaging using 18F-fluorodeoxyglucose and 11C-acetoacetate radiotracers
    Alexandre St-Georges, Alexi Houle, Thomas Cenci +8
    EJNMMI PhysicsPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyHAL
  3. Assessing Body Image in Multiple Sclerosis: Adaptation and Validation of the Modified Body Image Scale
    Erica Grange, Alessia Susini, Giampaolo Brichetto +2
    Brain and behaviorPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Deep Learning Trained Without Target-Domain Labels Improves Risk Stratification Over Expert Coronary Calcium Reading on Routine Attenuation Correction CT
    A. Shanbhag, R. J. Miller, A. Killekar +13
    medRxivPreprintCC BY-NCFull textMedical imaging & radiologymedRxiv
  5. Assessing fertility-related quality of life and psychological distress among infertile women: A cross-sectional study
    International journal of reproductive biomedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
BibTeX
@article{nadig2026assessing,
  title = {{Assessing effects of low-dose CT attenuation correction on quantification and image quality on a LAFOV PET system with a modified NEMA-IQ phantom.}},
  author = {Vanessa Nadig and Jane Mackewn and Georgios Krokos and Lewis C Davies and Daniel Darian and Sarah-May Gould and Gary J R Cook and Alexander Hammers and Andrew J Reader and Paul K Marsden},
  journal = {Medical physics},
  year = {2026},
  month = nov,
  doi = {10.1002/mp.70706},
  url = {https://europepmc.org/article/MED/42968509},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Assessing effects of low-dose CT attenuation correction on quantification and image quality on a LAFOV PET system with a modified NEMA-IQ phantom.
AU  - Vanessa Nadig
AU  - Jane Mackewn
AU  - Georgios Krokos
AU  - Lewis C Davies
AU  - Daniel Darian
AU  - Sarah-May Gould
AU  - Gary J R Cook
AU  - Alexander Hammers
AU  - Andrew J Reader
AU  - Paul K Marsden
PY  - 2026
DA  - 2026/11/01
JO  - Medical physics
DO  - 10.1002/mp.70706
UR  - https://europepmc.org/article/MED/42968509
AB  - Background  Over the past decades, efforts have been directed toward increasing the sensitivity of PET systems to enable low-dose PET imaging and shorter scan times. The Biograph Vision Quadra PET/CT scanner (Siemens Healthineers, Knoxville, TN, USA) combines an increased solid angle coverage with time of flight, enabling a significant reduction in administered activity. To fully benefit from low-dose PET imaging, the dose of the CT scan should ideally also be reduced.Purpose  The CT radiation dose can be reduced by lowering the tube voltage and exposure as well as by the use of tin filtration. Reducing the CT dose must be carefully aligned with any impact that changing CT image quality and quantitative metrics may have on the PET quantification, for example via linear attenuation coefficients. We evaluate the impact of low-dose CT protocols on the PET quantification in soft-tissue-like and bone-equivalent materials using a customized phantom.Methods  The phantom was assembled out of a NEMA-IQ phantom, several layers of saline and two bovine long bones, to simulate a patient positioned with arms down. A 10-min PET scan with 47 different accompanying CT scans was acquired. The CT tube voltage and exposure were varied between 70kVto140kV , with and without tin filtration, and 7mAsto400mAs , respectively. The effect of the different CT parameters on the PET image quality and quantitative accuracy was assessed via several quantitative metrics, including standardized uptake value (SUV) and signal-to-noise ratio, along with the CT dose length product (DLP).Results  The recorded DLP values suggest that using all tube voltages except 140kV combined with exposures in the range of 7mAsto30mAs , can result in dose savings of ≥ 80% compared to a typical clinical protocol ( 120kV , 50mAs ). Compared to this typical protocol, HU differed more in bone ( 10%to40% difference) than in soft tissue ( 1%to30% difference), and more streak artefacts and photon starvation were seen when configuring low tube voltages and exposures, with an accompanying increase in CT noise. The observed artefacts were transferred with low intensity to the PET images via the attenuation map. The SUVmean remained within 2% of the SUVmean of the typical clinical protocol for most tested protocols. The presence of artefacts in the CT images had a bigger impact on PET quantification in both soft tissue and bone ( SUVmean difference of 10%to20% ) than any difference in HU. Protocols that resulted in artefacts showed an increased inaccuracy in attenuation correction and scatter estimation, as assessed via the "lung" residual error (up to 10%to20% increase).Conclusions  Even for low-dose CT protocols, PET quantification remained consistent in all NEMA-IQ spheres for many materials. Beam hardening and photon starvation in the CT image are likely to occur in specific body regions such as hips, shoulders or the abdomen for an arms-down scan and these effects had a bigger impact on the quantification than any difference in HU in both soft tissue and bone. This therefore should be considered when selecting suitable CT imaging parameters.
SN  - 0094-2405
SN  - 2473-4209
ER  -